A Review of EEG and MEG Epileptic Spike Detection Algorithms
Open accessThe DOI matches its Crossref record; 80 of the 81 references it cites were found in a registry or an index.
Abstract
Epilepsy is one of the most serious disorders that affect patients' daily lives. When seizures occur, patients cannot control their behaviors, which can lead to serious injuries. With the great advances in recording both electroencephalogram (EEG) and magnetoencephalography (MEG) signals, it has become possible to analyze these signals in an automated manner for information extraction to help in seizure detection and prediction. Both EEG and MEG recordings of epilepsy patients contain spikes that can be used for the localization of epileptogenic zones, efficient onset detection, and even, in some cases, prediction. In this paper, we consider the characteristics of EEG and MEG spikes, present a discussion of the importance of spike detection in both signal modalities, and provide a review of spike detection algorithms. Since EEG signals have been widely used for decades, most of the algorithms presented in this paper cover the EEG spike detection methods. Few works in the literature are dedicated to MEG spike detection. Nevertheless, we assert that with some modifications, a considerable number of EEG spike detection algorithms can be applied to MEG signals. We classify the spike detection algorithms according to the domain used for processing the signal. Finally, we conclude with future research directions and open problems in this area.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This indicates that IENet extracts the features of abnormal discharge as the basis for seizure detection, similar to the prior knowledge based algorithms to manually extract relevant features such as spikes [100].”
From IENet: a robust convolutional neural network for EEG based brain-computer interfaces (2022) · cites this paper as [100]
Citations
Cites
Image Features From Phase Congruency
Kovesi, P. D. (1995) · UWA Profiles and Research Repository (UWA) · Cited by 1,246
Magnetoencephalography for Brain Electrophysiology and Imaging
Baillet, S. (2017) · Nature Neuroscience · doi:10.1038/nn.4504 · Cited by 992
EEG and MEG: Relevance to Neuroscience
Lopes da Silva, F. (2013) · Neuron · doi:10.1016/j.neuron.2013.10.017 · Cited by 900 · cited 1×
“An important difference between EEG and MEG signals is that the decay rate of the magnetic field is higher than that of the electric field [8]–[10].”
BackgroundCohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785
Magnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750 · cited 1×
“To reduce the noise of these signals and yield clean MEG signals, superconducting quantum interference device (SQUID) detectors have been used [5]–[7].”
MethodAutomatic recognition and quantification of interictal epileptic activity in the human scalp EEG
Gotman, J., & Gloor, P. (1976) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(76)90063-8 · Cited by 424 · cited 4×
“Gotman and Gloor [30] and Gotman et al.”
BackgroundInfluentialEEG seizure detection and prediction algorithms: a survey
Alotaiby, T. N., Alshebeili, S. A., Alshawi, T., Ahmad, I., & Abd El-Samie, F. E. (2014) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/1687-6180-2014-183 · Cited by 292 · cited 1×
“The wavelet transform has gained popularity in medical signal processing applications, because it translates a signal into an approximation component having most of the signal energy and several detailed components that show sharp transitions in a signal clearly [77].”
BackgroundWavelet preprocessing for automated neural network detection of EEG spikes
Kalayci, T., & Ozdamar, O. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.376754 · Cited by 264 · cited 4×
“Kalayci and Ozdamar [80] suggested the use of a five-level wavelet transform prior to a neural classifier for epileptic EEG spike detection.”
InfluentialComputer analysis of EEG signals with parametric models
Isaksson, A., Wennberg, A., & Zetterberg, L. H. (1981) · Proceedings of the IEEE · doi:10.1109/proc.1981.11988 · Cited by 204 · cited 1×
“[65] investigated the use of parametric methods, such as autoregressive (AR) and autoregressive moving average (ARMA) models, to create time-invariant models for EEG signals.”
MethodAutomated interictal EEG spike detection using artificial neural networks
Gabor, A. J., & Seyal, M. (1992) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(92)90086-w · Cited by 165 · cited 3×
“Gabor and Seyal [41] presented a time-domain spike detection approach adopting an error-back-propagation feed-forward neural network classifier.”
BackgroundMethodInfluential
Research works printed but not linked: 3
- 2017, fact sheet
- 2012, 10/20 System Positioning Manual
- okada, 1983, Neurogenesis of evoked magnetic fields, Biomagnetism An Interdisciplinary Approach, 399
Cited by
Virtual brain twins: from basic neuroscience to clinical use
Wang, H., Triebkorn, P., Breyton, M., Dollomaja, B., Lemaréchal, J.-D., Petkoski, S., Sorrentino, P., Depannemaecker, D., Hashemi, M., & Jirsa, V. (2024) · National Science Review · doi:10.1093/nsr/nwae079 · Cited by 195
“For non-invasive epileptogenicity estimation, the spike rate in MEG or EEG can serve as a pertinent data feature [28 ].”
BackgroundNizamis, K., Athanasiou, A., Almpani, S., Dimitrousis, C., & Astaras, A. (2021) · Sensors · doi:10.3390/s21062084 · Cited by 147
“Currently, convo‐ lutional neural networks (CNNs) are considered part of the state‐of‐the‐art among AI models for OC [222].”
BackgroundInfluentialA Brief Introduction to Magnetoencephalography (MEG) and Its Clinical Applications
Fred, A. L., Kumar, S. N., Haridhas, A. K., Ghosh, S., Bhuvana, H. P., Sim, W. K. J., Vijayaragavan, V., Givo, F. A. S., Jousmäki, V., Padmanabhan, P., et al. (2022) · Brain Sciences · doi:10.3390/brainsci12060788 · Cited by 130
“are identified in the time and frequency domain methods [61].”
BackgroundDeep learning for robust detection of interictal epileptiform discharges
Geng, D., Alkhachroum, A. M., Bicchi, M. M., Jagid, J. R., Cajigas, I., & Chen, Z. S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf28e · Cited by 74
Computer-assisted EEG diagnostic review for idiopathic generalized epilepsy
Clarke, S., Karoly, P. J., Nurse, E., Seneviratne, U., Taylor, J., Knight-Sadler, R., Kerr, R., Moore, B., Hennessy, P., Mendis, D., et al. (2021) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2019.106556 · Cited by 55
Metadata
- Authors
- Abd El-Samie, F. E., Alotaiby, T. N., Khalid, M. I., Alshebeili, S. A., & Aldosari, S. A.
- Affiliations
- King Abdulaziz City for Science and Technology (SA)
- Venue
- IEEE Access
- Published
- 2018
- Volume
- 6
- Pages
- 60673-60688
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2896977870
- Cited by
- 82
- References
- 81
- Citations by year
- 2026: 2 · 2025: 7 · 2024: 8 · 2023: 10 · 2022: 16 · 2021: 22 · 2020: 6 · 2019: 11
- FWCI
- 5.81
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- IEEE Access (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- KACST-Lockheed Martin University Funding Program
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Clinical Neurology › Epilepsy research and treatment
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- epileptic spike detection, EEG, magnetoencephalography, epilepsy, seizure detection, seizure prediction, epileptogenic zone localization, automated signal analysis, algorithm classification
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.