Power Quality in Microgrids Including Supraharmonics: Issues, Standards, and Mitigations

Open access
Alkahtani, Ammar Ahmed, Alfalahi, Saad T. Y., Athamneh, Abedalgany Abedallah, Al-Shetwi, Ali Q., Mansor, Muhamad Bin, Hannan, M. A., Agelidis, Vassilios G. · 2020 · IEEE Access
Cited by 195

The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.

Abstract

A microgrid (MG) is a small-scale power system with a cluster of loads and distributed generators operating together through energy management software and devices that act as a single controllable entity with respect to the grid. MG has become a key research element in smart grid and distribution power systems. MG mainly contains different renewable energy sources (RESs) that use various technological advancements, such as power electronics-based technologies. However, it has an unstable output, thereby causing different types of power quality (PQ) events. As a result, standards and mitigation methods have been developed in recent years. To mitigate PQ issues due to MG integration, various methods and standards have been proposed over the last years. Although these individual methods are well documented, a comparative overview had not been introduced so far. Thus, this study aims to fill the gap by reviewing and comparing the prior-art PQ issues, solutions, and standards in MGs. We compare the main issues related to voltage sag, voltage swell, voltage and current harmonics, system unbalances, and fluctuations to ensure high-quality MG output power. The new technologies associated with MGs generate harmonics emission in the range of 2-150 kHz, thereby causing a new phenomenon, namely, supraharmonics (SH) emission, which is not sufficiently covered in the literature. Therefore, the characteristics, causes, consequences, and measurements of SH are highlighted and analyzed. The mitigation strategies, control, and devices of PQ issues are also discussed. Moreover, a comparison is conducted between the most popular devices used to mitigate the PQ issues in MG in terms of cost, rating, and different aspects of performance. This review study can strengthen the efforts toward the mitigation and standards development of PQ issues in MG applications, especially SH. Finally, some recommendations and suggestions to improve PQ of MG, including SH, are highlighted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/access.2020.3008042

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 52 references

Cited by

See all 195

Metadata

Authors
Alkahtani, A. A., Alfalahi, S. T. Y., Athamneh, A. A., Al-Shetwi, A. Q., Mansor, M. B., Hannan, M. A., & Agelidis, V. G.
Venue
IEEE Access
Published
2020
Volume
8
Pages
127104-127122
ISSN
2169-3536 (ISSN-L)
OpenAlex
W3041059612
Cited by
195
References
52
FWCI
8.19
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Power Quality in Microgrids Including Supraharmonics: Issues, Standards, and Mitigations. https://app.cochat.ai/papers/10.1109/access.2020.3008042
The paper
Alkahtani, A. A., Alfalahi, S. T. Y., Athamneh, A. A., Al-Shetwi, A. Q., Mansor, M. B., Hannan, M. A., & Agelidis, V. G. (2020). Power Quality in Microgrids Including Supraharmonics: Issues, Standards, and Mitigations. IEEE Access. https://doi.org/10.1109/access.2020.3008042

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.