The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
McKibben artificial muscles: pneumatic actuators with biomechanical intelligence
Abstract
Reports on the design of a biorobotic actuator. Biological requirements are developed from published reports in the muscle physiology literature whose parameters are extracted and applied in the form of the Hill muscle model. Data from several vertebrate species (rat, frog, cat, and human) are used to evaluate the performance of a McKibben pneumatic actuator. The experimental results show the force-length properties of the actuator are muscle-like, but the force-velocity properties are not. The design of a hydraulic damper with fixed orifices, placed in parallel with the McKibben actuator, is proposed to improve the force-velocity performance. Simulation results of this practical design indicate a significant improvement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The heat of shortening and the dynamic constants of muscle
Hill, A. V. (1938) · Proceedings of the Royal Society of London. Series B - Biological Sciences · doi:10.1098/rspb.1938.0050 · Cited by 3,669
Measurement and modeling of McKibben pneumatic artificial muscles
Chou, C.-P., & Hannaford, B. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.481753 · Cited by 1,589
Self-citationThe relation between force and velocity in human muscle
Wilkie, D. R. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004437 · Cited by 632
(1995) · Cited by 293
Woittiez, R. D., Huijing, P. A., Boom, H. B. K., & Rozendal, R. H. (1984) · Journal of Morphology · doi:10.1002/jmor.1051820107 · Cited by 234
A model of the human triceps surae muscle-tendon complex applied to jumping
Bobbert, M. F., Huijing, P. A., & van Ingen Schenau, G. J. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90184-3 · Cited by 200
Development of Useful Function in the Severely Paralyzed Hand
NICKEL, V. L., PERRY, J., & GARRETT, A. L. (1963) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196345050-00004 · Cited by 197
THE MECHANICAL PROPERTIES OF MUSCLE
Wilkie, D. R. (1956) · British Medical Bulletin · doi:10.1093/oxfordjournals.bmb.a069546 · Cited by 194
The relation between velocity of shortening and the tension‐length curve of skeletal muscle
Abbott, B. C., & Wilkie, D. R. (1953) · The Journal of Physiology · doi:10.1113/jphysiol.1953.sp004886 · Cited by 190
Comparison of mechanical properties between slow and fast mammalian muscles
Wells, J. B. (1965) · The Journal of Physiology · doi:10.1113/jphysiol.1965.sp007626 · Cited by 169
Hof, A. L., & van den Berg, J. (1981) · Journal of Biomechanics · doi:10.1016/0021-9290(81)90032-4 · Cited by 93
Isokinetic plantar flexion: Experimental results and model calculations
Bobbert, M. F., & Schenau, G. J. V. I. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90345-4 · Cited by 83
Series elastic component of mammalian skeletal muscle
Bahler, A. (1967) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1967.213.6.1560 · Cited by 80
Modeling of Mammalian Skeletal Muscle
Bahler, A. S. (1968) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1968.4502575 · Cited by 68
Dynamic Features of Human Isolated Voluntary Muscle in Isometric and Free Contractions
Ralston, H. J., Polissar, M. J., Inman, V. T., et al. (1949) · Journal of Applied Physiology · doi:10.1152/jappl.1949.1.7.526 · Cited by 55
Mechanical properties of cat tenuissimus muscle
McCrorey, H. L., Gale, H. H., & Alpert, N. R. (1966) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1966.210.1.114 · Cited by 22
Research works printed but not linked: 2
- klute, 1998, Modeling pneumatic McKibben artificial muscle actuators: approaches and experimental results, Journal of Dynamic Systems Measurements and Control
- 10.1007/s003600050138 · doi:10.1007/s003600050138
Cited by
Soft Robotics: Biological Inspiration, State of the Art, and Future Research
Trivedi, D., Rahn, C. D., Kier, W. M., & Walker, I. D. (2008) · Applied Bionics and Biomechanics · doi:10.1080/11762320802557865 · Cited by 1,708
Soft robotic glove for combined assistance and at-home rehabilitation
Polygerinos, P., Wang, Z., Galloway, K. C., Wood, R. J., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.014 · Cited by 1,617
Materials that couple sensing, actuation, computation, and communication
McEvoy, M. A., & Correll, N. (2015) · Science · doi:10.1126/science.1261689 · Cited by 650
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Towards a soft pneumatic glove for hand rehabilitation
Polygerinos, P., Lyne, S., Wang, Z., Nicolini, L. F., Mosadegh, B., Whitesides, G. M., & Walsh, C. J. (2013) · 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2013.6696549 · Cited by 527
Metadata
- Authors
- Klute, G. K., Czerniecki, J. M., & Hannaford, B.
- Venue
- 1999 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (Cat. No.99TH8399)
- Publisher
- IEEE
- Published
- 1999
- Pages
- 221-226
- ISSN
- 2159-6247 (ISSN-L)
- OpenAlex
- W2108358935
- Cited by
- 308
- References
- 16
- FWCI
- 12.86
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.