Abstract
The operation and design trade-offs of the interleaved boost converter in continuous inductor-current mode in a high-power-factor preregulator circuit are investigated. By using interleaved converters, an overall reduction of boost inductor and electromagnetic interference (EMI) filter volume can be achieved, together with reduced switching losses. The problem of unequal load sharing between the interleaved power stages with average current control is pointed out, and a practical solution is recommended. EMI filter design considerations and experimental data taken from a 3 kW converter are presented.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Review of Three-Phase Improved Power Quality AC–DC Converters
Singh, B., Singh, B. N., Chandra, A., Al-Haddad, K., Pandey, A., & Kothari, D. P. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825341 · Cited by 1,728
A review of single-phase improved power quality ac~dc converters
Singh, B., Singh, B. N., Chandra, A., Al-Haddad, K., Pandey, A., & Kothari, D. P. (2003) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2003.817609 · Cited by 1,297
Un-Noor, F., Padmanaban, S., Mihet-Popa, L., Mollah, M., & Hossain, E. (2017) · Energies · doi:10.3390/en10081217 · Cited by 809
Industrial Electronics for Electric Transportation: Current State-of-the-Art and Future Challenges
Williamson, S. S., Rathore, A. K., & Musavi, F. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2409052 · Cited by 527
Steady-state analysis of an interleaved boost converter with coupled inductors
Lee, P.-W., Lee, Y.-S., Cheng, D. K. W., & Liu, X.-C. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.857959 · Cited by 498
Musavi, F., Eberle, W., & Dunford, W. G. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2156753 · Cited by 376
Jang, Y., & Jovanovic, M. M. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900502 · Cited by 352
Evaluation and Efficiency Comparison of Front End AC-DC Plug-in Hybrid Charger Topologies
Musavi, F., Edington, M., Eberle, W., & Dunford, W. G. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2166413 · Cited by 296
An Automotive Onboard 3.3-kW Battery Charger for PHEV Application
Gautam, D. S., Musavi, F., Edington, M., Eberle, W., & Dunford, W. G. (2012) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2012.2210259 · Cited by 274
Soft Switching Circuit for Interleaved Boost Converters
Yao, G., Chen, A., & He, X. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886649 · Cited by 180
Interleaved Critical Current Mode Boost PFC Converter With Coupled Inductor
Yang, F., Ruan, X., Yang, Y., & Ye, Z. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106165 · Cited by 177
Parasitic Ringing and Design Issues of Digitally Controlled High Power Interleaved Boost Converters
Huang, X., Wang, X., Nergaard, T., Lai, J.-S., Xu, X., & Zhu, L. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833434 · Cited by 165
“The basic idea behind the interleaved legs is to delay the switching in each leg so as to cancel the input current ripple [4].”
BackgroundAn interleaved AC-DC converter based on current tracking
Hwu, K. I., & Yau, Y. T. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2010174 · Cited by 58
“In [14]– [20], two phases of the ac–dc converter operate in CCM under the fixed switching frequency with the fixed interleaved phase angle of 180◦.”
Background
Metadata
- Authors
- Balogh, L., & Redl, R.
- Venue
- Proceedings Eighth Annual Applied Power Electronics Conference and Exposition,
- Publisher
- IEEE
- Published
- 2002-12-30
- Pages
- 168-174
- OpenAlex
- W2103988247
- Cited by
- 209
- References
- 0
- FWCI
- 13.18
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.