A unified control scheme for harmonic elimination in the front end converter of a 13.8 kV, 100 kVA transformerless intelligent power substation grid tied with LCL filter
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper proposes a simple control scheme to eliminate the lower order harmonics in the line currents of the Front End Converter (FEC) of a 100 kVA Transformerless Intelligent Power Substation (TIPS) connected to the medium voltage (13.8 kV) grid through an LCL filter. Due to medium voltage (13.8 kV) and low power (100 kVA) specification for the FEC, the control technique needs to be specially designed to control very low magnitude of line current (4.2 A rms). Lower order harmonics are present in the grid current due to dead time in the FEC and grid voltage harmonics. Low switching frequency along with the medium voltage and low power levels results in a filter capacitor value that offers low impedance to the lower order harmonic currents. This lower order harmonic current flow through the filter capacitor limits the power that can be delivered by the converter due to lower current rating of the FEC. It also pollutes the control loop and affect system stability. This paper proposes a simple unified control scheme with harmonic current elimination under such conditions. The control scheme eliminates these harmonics in the grid current by regulating the harmonics in the filter capacitor voltage and inductor currents, both on grid side and converter side. System modeling, simulation and experimental results validate the proposed control scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Madhusoodhanan, S., Hatua, K., Bhattacharya, S., Leslie, S., Ryu, S.-H., Das, M., Agarwal, A., & Grider, D. (2012) · 2012 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2012.6342807 · Cited by 80 · cited 2×
“High dv/dt seen by the 15 kV SiC IGBTs used in the FEC limits the switching frequency of operation to 3 to 5 kHz due to hard switching of these devices [1], [3].”
BackgroundSelf-citation
Cited by
Madhusoodhanan, S., Tripathi, A., Patel, D., Mainali, K., Kadavelugu, A., Hazra, S., Bhattacharya, S., & Hatua, K. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2412096 · Cited by 371
Self-citationChattopadhyay, R., De, A., & Bhattacharya, S. (2014) · 2014 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6953895 · Cited by 35
Self-citationMadhusoodhanan, S., Tripathi, A., Patel, D., Mainali, K., Kadavelugu, A., Hazra, S., Bhattacharya, S., & Hatua, K. (2014) · 2014 International Power Electronics Conference (IPEC-Hiroshima 2014 - ECCE ASIA) · doi:10.1109/ipec.2014.6869800 · Cited by 25
Self-citationMadhusoodhanan, S., Mainali, K., Tripathi, A., Patel, D., Kadavelugu, A., Bhattacharya, S., & Hatua, K. (2015) · 2015 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2015.7310184 · Cited by 13
Self-citation
Metadata
- Authors
- Madhusoodhanan, S., Bhattacharya, S., & Hatua, K.
- Venue
- 2014 IEEE Applied Power Electronics Conference and Exposition - APEC 2014
- Publisher
- IEEE
- Published
- 2014-03
- Volume
- 31
- Pages
- 964-971
- OpenAlex
- W1989887738
- Cited by
- 14
- References
- 1
- FWCI
- 4.88
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.