CoChat

High-Frequency Transformer Design with High-Voltage Insulation for Modular Power Conversion from Medium-Voltage AC to 400-V DC

Li, Zheqing, Hsieh, Yi-Hsun, Li, Qiang, Lee, Fred C., Ahmed, Mohamed H. · 2020 · 2020 IEEE Energy Conversion Congress and Exposition (ECCE)

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

CCG Facility Integration proposed that the 4.16-kVAC power distribution in a data center greatly reduces the loss on cable, especially when compared to 480-VAC distribution. Also, it is suggested that the minimum stage of power conversion is obtained by powering each server rack with a 400-VDC bus that is directly step-downed from the 4.16-kVAC. An input-series-output-parallel (ISOP) structure becomes a promising topology for this power conversion. In addition to the modularity, the medium voltage (MV) is handled by efficient low-voltage devices connected in series, leading to high efficiency and high power density. The transformer in the DC/DC converter is crucial, since it is responsible for the MV insulation. Since insulation occupies a significant space in the transformer, the conventional optimization approach needs to be re-evaluated, especially in regard to switching frequency. The increase in spacing provides the opportunity to integrate the resonant inductor into the transformer. In this paper, a new optimization method for switching frequency is proposed with a better insulation structure. The design is demonstrated on a 200-kHz CLLC converter with 98.7 % efficiency and 61 W/in3power density.

Overview

Integrity signals

Registry

Crossref · 10.1109/ecce44975.2020.9236384

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 11 references

Research works printed but not linked: 2

  1. 2015, IEEE Standard C57 12 01-2015 (Revision of IEEE Standard C57 12 01-2005)
  2. 2014, NFPA 70 National Electrical Code 2014 Edition Table 310 15(B)(16) (formerly Table 310 16), 70

Cited by

See all 71

Metadata

Authors
Li, Z., Hsieh, Y.-H., Li, Q., Lee, F. C., & Ahmed, M. H.
Affiliations
Virginia Tech (US)
Venue
2020 IEEE Energy Conversion Congress and Exposition (ECCE)
Publisher
IEEE
Published
2020-10-11
Pages
5053-5060
OpenAlex
W3097697428
Cited by
71
References
11
Citations by year
2025: 8 · 2024: 9 · 2023: 29 · 2022: 13 · 2021: 12
FWCI
18.98
Type
conference paper
Language
en
Open access
closed
Locations
IEEE Energy Conversion Congress and Exposition (ECCE) (publishedVersion)
Funders
Office of Energy Efficiency and Renewable Energy
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
Keywords
high-frequency transformer design, high-voltage insulation, input-series output-parallel topology, DC-DC converter, CLLC converter, switching frequency optimization, power density, modular power conversion

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Frequency Transformer Design with High-Voltage Insulation for Modular Power Conversion from Medium-Voltage AC to 400-V DC. https://app.cochat.ai/papers/10.1109/ecce44975.2020.9236384
The paper
Li, Z., Hsieh, Y.-H., Li, Q., Lee, F. C., & Ahmed, M. H. (2020). High-Frequency Transformer Design with High-Voltage Insulation for Modular Power Conversion from Medium-Voltage AC to 400-V DC. 2020 IEEE Energy Conversion Congress and Exposition (ECCE). https://doi.org/10.1109/ecce44975.2020.9236384

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.