A wearable system for long-term ubiquitous monitoring of common motor symptoms in patients with Parkinson's disease
Abstract
PERFORM is a system for the monitoring, assessment and management of patient with Parkinson's disease (PD). It comprises of three subsystems: (i) Multi-Sensor Monitoring Unit, (ii) the Local Base Unit, and (iii) the Centralized Hospital unit. The wearable, multi-sensor monitoring unit (WMSMU) of the PERFORM system is presented in this work. This unit plays an essential role in the overall PERFORM system since it is responsible to record and pre-process accelerometer and gyroscope signals that are later used by the various components of the Local Base Unit in order to classify and quantify the symptoms and motor status of the PD patients. The WMSMU was evaluated in a large set of pilot studies in PD patients.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The PERFORM system is a wearable platform for Parkinson's disease remote monitoring and management, based on a Body Area Network (BAN) of sensors.
“This system, called PERFORM, is based on a Body Area Network (BAN) of sensors which has already been validated both from the technical and clinical point for view.”
From Wearability Assessment of a Wearable System for Parkinson’s Disease Remote Monitoring Based on a Body Area Network of Sensors (2014) · cites this paper as [15]
Cites
Najafi, B., Aminian, K., Paraschiv-Ionescu, A., Loew, F., Büla, C., & Robert, P. A. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.812189 · Cited by 760 · see citing works
Monitoring Motor Fluctuations in Patients With Parkinson's Disease Using Wearable Sensors
Patel, S., Lorincz, K., Hughes, R., Huggins, N., Growdon, J., Standaert, D., Akay, M., Dy, J., Welsh, M., & Bonato, P. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033471 · Cited by 623 · see citing works
Salarian, A., Russmann, H., Wider, C., Burkhard, P. R., Vingerhoets, F. J. G., & Aminian, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886670 · Cited by 416 · see citing works
Parkinson's Disease and Movement Disorders
Goetz, C. G. (1998) · JAMA · doi:10.1001/jama.280.20.1796-a · Cited by 317 · see citing works
Assessment of Tremor Activity in the Parkinson’s Disease Using a Set of Wearable Sensors
Rigas, G., Tzallas, A. T., Tsipouras, M. G., Bougia, P., Tripoliti, E. E., Baga, D., Fotiadis, D. I., Tsouli, S. G., & Konitsiotis, S. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2182616 · Cited by 241 · see citing works
Self-citationAutomatic assessment of levodopa‐induced dyskinesias in daily life by neural networks
Keijsers, N., Horstink, M. W. I. M., & Gielen, S. C. A. M. (2002) · Movement Disorders · doi:10.1002/mds.10310 · Cited by 139 · see citing works
Tsipouras, M. G., Tzallas, A. T., Rigas, G., Tsouli, S. G., Fotiadis, D. I., & Konitsiotis, S. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.03.003 · Cited by 92 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
How Wearable Sensors Can Support Parkinson's Disease Diagnosis and Treatment: A Systematic Review
Rovini, E., Maremmani, C., & Cavallo, F. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00555 · Cited by 446 · see citing works
PERFORM: A System for Monitoring, Assessment and Management of Patients with Parkinson’s Disease
Tzallas, A. T., Tsipouras, M. G., Rigas, G., Tsalikakis, D., Karvounis, E. C., Chondrogiorgi, M., Psomadellis, F., Cancela, J., Pastorino, M., Arredondo, M. T., et al. (2014) · Sensors · doi:10.3390/s141121329 · Cited by 170 · see citing works
Self-citationChanna, A., Popescu, N., & Ciobanu, V. (2020) · Sensors · doi:10.3390/s20092713 · Cited by 114 · see citing works
Cancela, J., Pastorino, M., Tzallas, A., Tsipouras, M., Rigas, G., Arredondo, M., & Fotiadis, D. (2014) · Sensors · doi:10.3390/s140917235 · Cited by 97 · see citing works
Self-citationA multiple motion sensors index for motor state quantification in Parkinson's disease
Aghanavesi, S., Westin, J., Bergquist, F., Nyholm, D., Askmark, H., Aquilonius, S. M., Constantinescu, R., Medvedev, A. V., Spira, J., Ohlsson, F., et al. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.105309 · Cited by 18 · see citing works
Wearable antenna design for bioinformation
Pei, R., Wang, J., Leach, M. P., Wang, Z., Lee, S., & Lim, E. G. (2016) · IEEE Conference on Computational Intelligence in Bioinformatics and Computational Biology (CIBCB) · doi:10.1109/cibcb.2016.7758129 · Cited by 10 · see citing works
Citizen Engagement in the mHealth Ecosystem Using Mobiles and Wearable Devices
Kouris, I., & Koutsouris, D.-D. (2015) · Annals of information systems · doi:10.1007/978-3-319-23341-3_3 · Cited by 3 · see citing works
Cancela, J., Pastorino, M., & Arredondo, M. T. (2017) · IGI Global eBooks · doi:10.4018/978-1-5225-3158-6.ch050 · Cited by 2 · see citing works
Self-citationJalloul, N., Porée, F., Viardot, G., L’Hostis, P., & Carrault, G. (2015) · International Conference on Advances in Biomedical Engineering (ICABME) · doi:10.1109/icabme.2015.7323273 · Cited by 2 · see citing works
Cancela, J., Pastorino, M., & Arredondo, M. T. (2015) · Advances in medical diagnosis, treatment, and care (AMDTC) book series · doi:10.4018/978-1-4666-8828-5.ch023
Self-citationCancela, J., Pastorino, M., & Arredondo, M. T. (2018) · IGI Global eBooks · doi:10.4018/978-1-5225-5484-4.ch064
Self-citationProgram in chronological order
(2014) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2014.6864288
- Authors
- Tsipouras, M. G., Tzallas, A. T., Karvounis, E. C., Tsalikakis, D. G., Cancela, J., Pastorino, M., Waldmeyer, M. T. A., Konitsiotis, S., & Fotiadis, D. I.
- Affiliations
- University of Ioannina (GR)
- University of Western Macedonia (GR)
- Universidad Politécnica de Madrid (ES)
- ORCID
- Venue
- IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI)
- Publisher
- IEEE
- Published
- 2014-06
- Volume
- 54
- Pages
- 173-176
- ISSN
- 2641-3590 (ISSN-L)
- OpenAlex
- W2060221488
- Cited by
- 13
- References
- 7
- Citations by year
- 2020: 3 · 2018: 1 · 2017: 2 · 2016: 1 · 2015: 3 · 2014: 3
- FWCI
- 1.61
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- Parkinson's disease, wearable sensors, accelerometer, gyroscope, motor symptom monitoring, ubiquitous health monitoring, symptom classification
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review