High performance p300 speller for brain-computer interface
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
P300 speller is a communication tool with which one can input texts or commands to a computer by thought. The amplitude of the P300 evoked potential is inversely proportional to the probability of infrequent or task-related stimulus. In existing P300 spellers, rows and columns of a matrix are intensified successively and randomly, resulting in a stimulus frequency of 1/N (N is the number of rows or columns of the matrix). We propose a new paradigm to display each single character randomly and individually (therefore reducing the stimulus frequency to 1/(N*N)). On-line experiments showed that this new speller significantly improved the performance. Specifically, the new speller can reduce character classification error rate by up to 80% or double the information transfer rate compared to the existing P300 spellers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“A comprehensive review on BCI can be found in [1].”
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 2×
“…to develop BCI systems, for example, slow cortical potential [2], m and b rhythms [3], synchronization and desynchronization evoked by motor imagery [4], P300 evoked potential [5], static-state visual evoked potentials [6], etc. P300 potential is one of the well studied and most stable potentials.”
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990 · cited 1×
“synchronization and desynchronization evoked by motor imagery [4], P300 evoked potential [5], static-state visual evoked potentials [6], etc.”
The mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K. M., & Wijesinghe, R. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,222 · cited 1×
“Donchin etc [7] further improved the information transfer rate by using a bootstrapping approach.”
Brain-computer interfaces based on the steady-state visual-evoked response
Middendorf, M., McMillan, G., Calhoun, G., & Jones, K. S. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847819 · Cited by 685 · cited 1×
“synchronization and desynchronization evoked by motor imagery [4], P300 evoked potential [5], static-state visual evoked potentials [6], etc.”
Xu, N., Gao, X., Hong, B., Miao, X., Gao, S., & Yang, F. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826699 · Cited by 258
ERPs evoked by different matrix sizes: implications for a brain computer interface (BCI) system
Allison, B. Z., & Pineda, J. A. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814448 · Cited by 225 · cited 1×
“Brendan etc [11] studied the relationship between accuracy and various size of speller matrix.”
The Wadsworth Center brain-computer interface (BCI) research and development program
Wolpaw, J. R., McFarland, D. J., Vaughan, T. M., & Schalk, G. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814442 · Cited by 209 · cited 1×
“Various signals can be extracted from EEG to develop BCI systems, for example, slow cortical potential [2], m and b rhythms [3], synchronization and desynchronization evoked by motor imagery [4], P300 evoked potential [5], static-state visual evoked potentials [6], etc. P300 potential is one of the…”
The thought-translation device (TTD): neurobehavioral mechanisms and clinical outcome
Birbaumer, N., Hinterberger, T., Kubler, A., & Neumann, N. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814439 · Cited by 196 · cited 1×
“potential [2], μ and β rhythms [3],”
Improving Transfer Rates in Brain Computer Interfacing: A Case Study
Meinicke, P., Kaper, M., Hoppe, F., Heumann, M., & Ritter, H. J. (2002) · PUB – Publications at Bielefeld University (Bielefeld University) · Cited by 109
Cited by
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
How many people are able to control a P300-based brain-computer interface (BCI)?
Guger, C., Daban, S., Sellers, E., Holzner, C., Krausz, G., Carabalona, R., Gramatica, F., & Edlinger, G. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.045 · Cited by 652
“[3], and the results suggested that the SC paradigm produced larger P300 responses.”
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
Riemannian geometry for EEG-based brain-computer interfaces; a primer and a review
Congedo, M., Barachant, A., & Bhatia, R. (2017) · Brain-Computer Interfaces · doi:10.1080/2326263x.2017.1297192 · Cited by 456
A Brain Controlled Wheelchair to Navigate in Familiar Environments
Rebsamen, B., Guan, C., Zhang, H., Wang, C., Teo, C., Ang, M. H., & Burdet, E. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2049862 · Cited by 405
Self-citationAn end-to-end deep learning approach to MI-EEG signal classification for BCIs
Dose, H., Møller, J. S., Iversen, H. K., & Puthusserypady, S. (2018) · Expert Systems with Applications · doi:10.1016/j.eswa.2018.08.031 · Cited by 382
A Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299
Robust classification of EEG signal for brain-computer interface
Thulasidas, M., Guan, C., & Wu, J. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.862695 · Cited by 261
Self-citationMak, J. N., Arbel, Y., Minett, J. W., McCane, L. M., Yuksel, B., Ryan, D., Thompson, D., Bianchi, L., & Erdogmus, D. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025003 · Cited by 195
“The SC paradigm elicits a larger P300 (Guan et al 2004), but accuracy and speed of communication are reported to be lower than that of RC (Guger et al 2009).”
BackgroundA Parallel Multiscale Filter Bank Convolutional Neural Networks for Motor Imagery EEG Classification
Wu, H., Niu, Y., Li, F., Li, Y., Fu, B., Shi, G., & Dong, M. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.01275 · Cited by 175
“BCI have been applied to control the devices such as electric wheelchairs (Galán et al., 2008), text spellers (Guan et al., 2005), and prosthetic artificial limbs (Schwartz et al., 2006).”
MethodDecoding Covert Speech From EEG-A Comprehensive Review
Panachakel, J. T., & Ramakrishnan, A. G. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.642251 · Cited by 156
“P300-speller based BCI system (Guan et al., 2004; Guy et al., 2018; Arvaneh et al., 2019; Lu et al., 2019; Al-Nuaimi et al., 2020) is a quite successful BCI system.”
A comparison study of two P300 speller paradigms for brain–computer interface
Pan, J., Li, Y., Gu, Z., & Yu, Z. (2013) · Cognitive Neurodynamics · doi:10.1007/s11571-013-9253-1 · Cited by 46
“Single character (SC) speller The SC speller was first proposed in Guan et al. (2004).”
BackgroundMethodInfluential
Metadata
- Authors
- Guan, C., Thulasidas, M., & Wu, J.
- Venue
- IEEE International Workshop on Biomedical Circuits and Systems, 2004.
- Publisher
- IEEE
- Published
- 2005-06-28
- Pages
- 293-296
- OpenAlex
- W2545747245
- Cited by
- 165
- References
- 11
- FWCI
- 10.54
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.