Wireless Power and Data Link for Ensembles of Sub-mm scale Implantable Sensors near 1GHz
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We describe a custom wireless power and data transmission (WPDT) link and analyze its performance in a prototype implantable sensor system of ensembles of CMOS sensor ASICs (“Neurograins”) embedding 0.5 mm × 0.5 mm planar microcoil antennas. We use near-field RF at ~1 GHz for wireless powering in a resonant 3-coil architecture including an implanted relay coil in a quadrant layout architecture to maximize coverage area and RF transfer efficiency. We demonstrate successful WPDT across antenna cross-section in benchtop proxy physiological tests. Demodulation and analysis of backscattered signals validate the data link fidelity. Our results suggest that this electromagnetic coupling scheme can robustly support a chip density of 250/ cm2(up to 1024 individual Neurograins in a 2 cm × 2 cm area) and parallel transmitters can be combined to multiply the channel capacity without destructive interference.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A theory of multineuronal dimensionality, dynamics and measurement
Gao, P., Trautmann, E., Yu, B., Santhanam, G., Ryu, S., Shenoy, K., & Ganguli, S. (2017) · doi:10.1101/214262 · Cited by 332 · cited 1×
“However, their monolithic and wired configurations, commonly used for up to few hundred channels, have challenges in scaling up to record and decode neural signals associated with complex motor/sensory tasks [2].”
BackgroundNeural Dust: An Ultrasonic, Low Power Solution for Chronic Brain-Machine Interfaces
Seo, D., Carmena, J. M., Rabaey, J. M., Alon, E., & Maharbiz, M. M. (2013) · arXiv · doi:10.48550/arxiv.1307.2196 · Cited by 172
Cited by
Neural recording and stimulation using wireless networks of microimplants
Lee, J., Leung, V., Lee, A.-H., Huang, J., Asbeck, P., Mercier, P. P., Shellhammer, S., Larson, L., Laiwalla, F., & Nurmikko, A. (2021) · Nature Electronics · doi:10.1038/s41928-021-00631-8 · Cited by 195
Self-citationMiniaturised wireless power transfer systems for neurostimulation: a review
Barbruni, G. L., Ros, P. M., Demarchi, D., Carrara, S., & Ghezzi, D. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3038599 · Cited by 161
“Recently, 3-coils architectures were largely investigated [54], [55] and exploited to power sub-mm devices at large distances [56] with an optimal operating frequency between 400 MHz − 2 GHz [57].”
BackgroundChallenges for Large-Scale Cortical Interfaces
Nurmikko, A. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.015 · Cited by 68
Self-citationAn Implantable Wireless Network of Distributed Microscale Sensors for Neural Applications
Lee, J., Lee, F., Huang, J., Cui, L., Lee, A.-H., Leung, V., Mercier, P., Shellhammer, S., Larson, L., Asbeck, P., et al. (2019) · 2019 9th International IEEE/EMBS Conference on Neural Engineering (NER) · doi:10.1109/ner.2019.8717023 · Cited by 54
Self-citationMoon, E., Barrow, M., Lim, J., Lee, J., Nason, S. R., Costello, J., Kim, H. S., Chestek, C., Jang, T., Blaauw, D., et al. (2021) · ACS Photonics · doi:10.1021/acsphotonics.1c00160 · Cited by 31
Self-citation
Metadata
- Authors
- Lee, J., Laiwalla, F., Jeong, J., Kilfoyle, C., Larson, L., Nurmikko, A., Li, S., Yu, S., & Leung, V. W.
- Venue
- 2018 IEEE Biomedical Circuits and Systems Conference (BioCAS)
- Publisher
- IEEE
- Published
- 2018-10
- Pages
- 1-4
- OpenAlex
- W2906042634
- Cited by
- 35
- References
- 2
- FWCI
- 12.12
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wireless Power and Data Link for Ensembles of Sub-mm scale Implantable Sensors near 1GHz. https://app.cochat.ai/papers/10.1109/biocas.2018.8584725
- The paper
- Lee, J., Laiwalla, F., Jeong, J., Kilfoyle, C., Larson, L., Nurmikko, A., Li, S., Yu, S., & Leung, V. W. (2018). Wireless Power and Data Link for Ensembles of Sub-mm scale Implantable Sensors near 1GHz. 2018 IEEE Biomedical Circuits and Systems Conference (BioCAS). https://doi.org/10.1109/biocas.2018.8584725
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.