The DOI matches its Crossref record.
SPARKy 3: Design of an active robotic ankle prosthesis with two actuated degrees of freedom using regenerative kinetics
Abstract
The goal of modern prosthetics is to replicate the function of the replaced limb or organ in the most capable and discreet fashion possible. However, even the most advanced, commercial, transtibial prostheses available today only passively adjust the position of the ankle during the swing phase of gait and return a portion of the userpsilas own gravitational input. To greatly improve the quality of life of a transtibial amputee, new technologies and approaches must be used to create a cutting-edge robotic ankle prosthesis which can perform on par with, if not outperform, the equivalent able-bodied human ankle. Initial attempts by us and others have had great success in providing the natural gait power and motion through all ranges of walking speeds. A new design is presented which governs both the coronal and sagittal angles and moments of the ankle joint to potentially provide unprecedented levels of athleticism and agility among transtibial amputees.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“[3,206,223], mechanically-variable impedance actuation [224,225] and the reciprocal tr ansfer of power between joints [214,226-229] or between portions of the gait cycle [230-232].”
BackgroundPreliminary Evaluations of a Self-Contained Anthropomorphic Transfemoral Prosthesis
Sup, F., Varol, H. A., Mitchell, J., Withrow, T. J., & Goldfarb, M. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2009.2032688 · Cited by 298
Upslope Walking With a Powered Knee and Ankle Prosthesis: Initial Results With an Amputee Subject
Sup, F., Varol, H. A., & Goldfarb, M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2087360 · Cited by 283
Active lower limb prosthetics: a systematic review of design issues and solutions
Windrich, M., Grimmer, M., Christ, O., Rinderknecht, S., & Beckerle, P. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0284-9 · Cited by 272
A Locomotion Intent Prediction System Based on Multi-Sensor Fusion
Chen, B., Zheng, E., & Wang, Q. (2014) · Sensors · doi:10.3390/s140712349 · Cited by 69
Metadata
- Authors
- Bellman, R. D., Holgate, M. A., & Sugar, T. G.
- Venue
- 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics
- Publisher
- IEEE
- Published
- 2008-10
- Pages
- 511-516
- ISSN
- 2155-1774 (ISSN-L)
- OpenAlex
- W2117872137
- Cited by
- 163
- References
- 0
- FWCI
- 11.63
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SPARKy 3: Design of an active robotic ankle prosthesis with two actuated degrees of freedom using regenerative kinetics. https://app.cochat.ai/papers/10.1109/biorob.2008.4762887
- The paper
- Bellman, R. D., Holgate, M. A., & Sugar, T. G. (2008). SPARKy 3: Design of an active robotic ankle prosthesis with two actuated degrees of freedom using regenerative kinetics. 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics. https://doi.org/10.1109/biorob.2008.4762887
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.