The DOI matches its Crossref record.
Upslope Walking With a Powered Knee and Ankle Prosthesis: Initial Results With an Amputee Subject
Abstract
This paper extends a previously developed level- ground walking control methodology to enable an above knee amputee to walk up slopes using a powered knee and ankle prosthesis. Experimental results corresponding to walking on level ground and two different slope angles (5 (°) and 10 (°)) with the powered prosthesis using the control method are compared to walking under the same conditions with a passive prosthesis. The data indicate that the powered prosthesis with the upslope walking controller is able to reproduce several kinematic characteristics of healthy upslope walking that the passive prosthesis does not (such as knee flexion after heel strike and a powered ankle plantarflexion during push-off). Finally, results are shown that demonstrate the ability of the prosthesis to generate a slope estimate, which is in turn utilized to adapt the underlying control parameters to the corresponding slope.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“This information has also been used to trigger an activity mode transition [107-110,112,113].”
InfluentialA decade retrospective of medical robotics research from 2010 to 2020
Dupont, P. E., Nelson, B. J., Goldfarb, M., Hannaford, B., Menciassi, A., O’Malley, M. K., Simaan, N., Valdastri, P., & Yang, G.-Z. (2021) · Science Robotics · doi:10.1126/scirobotics.abi8017 · Cited by 516
Self-citationA review of current state-of-the-art control methods for lower-limb powered prostheses
Gehlhar, R., Tucker, M., Young, A. J., & Ames, A. D. (2023) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2023.03.003 · Cited by 131
A Locomotion Intent Prediction System Based on Multi-Sensor Fusion
Chen, B., Zheng, E., & Wang, Q. (2014) · Sensors · doi:10.3390/s140712349 · Cited by 69
Classifying the intent of novel users during human locomotion using powered lower limb prostheses
Young, A. J., Simon, A. M., Fey, N. P., & Hargrove, L. J. (2013) · 2013 6th International IEEE/EMBS Conference on Neural Engineering (NER) · doi:10.1109/ner.2013.6695934 · Cited by 55
Metadata
- Authors
- Sup, F., Varol, H. A., & Goldfarb, M.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-02
- Volume
- 19
- Issue
- 1
- Pages
- 71-78
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2134208106
- Cited by
- 283
- References
- 0
- FWCI
- 7.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Upslope Walking With a Powered Knee and Ankle Prosthesis: Initial Results With an Amputee Subject. https://app.cochat.ai/papers/10.1109/tnsre.2010.2087360
- The paper
- Sup, F., Varol, H. A., & Goldfarb, M. (2011). Upslope Walking With a Powered Knee and Ankle Prosthesis: Initial Results With an Amputee Subject. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2010.2087360
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.