Seismocardiography: a technique for recording precordial acceleration
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The methodology for obtaining a recording and the initial findings from the seismocardiography (SCG) technique are described. It is shown that the seismocardiogram contains clearly defined points associated with the cardiac cycle that are correlated by analyzing simultaneous SCG and M-mode and Doppler echocardiograms. In the absence of heart disease, the resting seismocardiogram remains stable over a period of at least three months. There is a recognizable normal seismocardiogram that is altered by chronic left ventricular dysfunction, including myocardial infarction and dilated cardiomyopathy. Ventricular pacing produces reversible changes in the ventricular systolic wave component of the seismocardiogram. Thus, the normal seismocardiogram remains stable over time, but becomes altered during both chronic irreversible and acute reversible changes in left ventricular contraction.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A critical review of the systolic time intervals.
Lewis, R. P., Rittogers, S. E., Froester, W. F., & Boudoulas, H. (1977) · Circulation · doi:10.1161/01.cir.56.2.146 · Cited by 624
Cited by
Liu, Y., Norton, J. J. S., Qazi, R., Zou, Z., Ammann, K. R., Liu, H., Yan, L., Tran, P. L., Jang, K.-I., Lee, J. W., et al. (2016) · Science Advances · doi:10.1126/sciadv.1601185 · Cited by 397
“…phonocardiography (PCG; sounds from the heart) ( 28 ), seismocardiography (SCG; vibrations of the chest induced by the beating of the heart) ( 29 – 34 ), ballistocardiography (BCG; recoil motions associated with reactions to cardiovascular pressure) ( 28 , 30 , 35 , 36 ), and sounds associated…”
Inan, O. T., Baran Pouyan, M., Javaid, A. Q., Dowling, S., Etemadi, M., Dorier, A., Heller, J. A., Bicen, A. O., Roy, S., De Marco, T., et al. (2018) · Circulation: Heart Failure · doi:10.1161/circheartfailure.117.004313 · Cited by 207
Pandia, K., Inan, O. T., Kovacs, G. T. A., & Giovangrandi, L. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/10/1643 · Cited by 114
Definition of Fiducial Points in the Normal Seismocardiogram
Sørensen, K., Schmidt, S. E., Jensen, A. S., Søgaard, P., & Struijk, J. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-33675-6 · Cited by 111
Etemadi, M., Inan, O. T., Heller, J. A., Hersek, S., Klein, L., & Roy, S. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2405480 · Cited by 95
“The duration of the inset is 2 minutes. with no incline produced a small increase in HR, SCG RMS power, and decrease in left ventricular ejection time (LVET) as estimated from the (to the first order as a reduction in the time delay between the first and second complex of the SCG signal).”
Influential
Metadata
- Authors
- Zanetti, J. M., & Salerno, D. M.
- Venue
- [1991] Computer-Based Medical Systems@m_Proceedings of the Fourth Annual IEEE Symposium
- Publisher
- IEEE Comput. Soc. Press
- Published
- 2002-12-10
- Pages
- 4-9
- OpenAlex
- W2104761030
- Cited by
- 103
- References
- 1
- FWCI
- 0.45
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Seismocardiography: a technique for recording precordial acceleration. https://app.cochat.ai/papers/10.1109/cbms.1991.128936
- The paper
- Zanetti, J. M., & Salerno, D. M. (2002). Seismocardiography: a technique for recording precordial acceleration. [1991] Computer-Based Medical Systems@m_Proceedings of the Fourth Annual IEEE Symposium. https://doi.org/10.1109/cbms.1991.128936
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.