Definition of Fiducial Points in the Normal Seismocardiogram
Open accessAbstract
The purpose of this work is to define fiducial points in the seismocardiogram (SCG) and to correlate them with physiological events identified in ultrasound images. For 45 healthy subjects the SCG and the electrocardiogram (ECG) were recorded simultaneously at rest. Immediately following the SCG and ECG recordings ultrasound images of the heart were also obtained at rest. For all subjects a mean SCG signal was calculated and all fiducial points (peaks and valleys) were identified and labeled in the same way across all signals. Eight physiologic events, including the valve openings and closings, were annotated from ultrasound as well and the fiducial points were correlated with those physiologic events. A total of 42 SCG signals were used in the data analysis. The smallest mean differences (±SD) between the eight events found in the ultrasound images and the fiducial points, together with their correlation coefficients (r) were: atrial systolic onset: −2 (±16) ms, r = 0.75 (p < 0.001); peak atrial inflow: 13 (±19) ms, r = 0.63 (p < 0.001); mitral valve closure: 4 (±11) ms, r = 0.71 (p < 0.01); aortic valve opening: −3 (±11) ms, r = 0.60 (p < 0.001); peak systolic outflow: 13 (±23) ms, r = 0.42 (p < 0.01); aortic valve closure: −5 (±12) ms, r = 0.94 (p < 0.001); mitral valve opening: −7 (±19) ms, r = 0.87 (p < 0.001) and peak early ventricular filling: −18 (±28 ms), r = 0.79 (p < 0.001). In conclusion eight physiologic events characterizeing the cardiac cycle, are associated with reproducible, well-defined fiducial points in the SCG.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The observed correspondence of AO and AC to heart sound features agrees with previous literature.
“This result agrees with previous literature. [38,39]”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [39]
The Results (Systolic complex and Diastolic complex; page unavailable) correlate SCG fiducial points with ultrasound-defined aortic valve opening (AO) and closure (AC). The Methods (Signal Processing of SCG Signals; page unavailable) use a heart-sound signal to align beats, but the paper does not establish that AO and AC correspond to particular heart-sound features. It therefore supports the valve-event correspondence, not the claimed heart-sound correspondence. (LLM, conf=0.84)
Experimental — accuracy not yet measuredThe aortic valve closing (AC) is near the beginning of the first major minima of the second heart sound.
“the AC is near the beginning of the first major minima of the second heart sound.”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [39]
The Results (Diastolic complex; page not available) place aortic valve closure near SCG fiducial point Bd, with a mean difference of −5 ms. The paper does not identify Bd as the beginning of the first major minimum of the second heart sound or establish that timing relationship. (LLM, conf=0.82)
Experimental — accuracy not yet measuredThe aortic valve opening (AO) corresponds to the first major peak of the first heart sound.
“the AO clearly corresponds to the first major peak of the first heart sound”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [39]
The Results (Systolic complex; page unavailable) correlate aortic valve opening with SCG fiducial point Gs. The Discussion (page unavailable) mentions the first heart sound in connection with a deflection near mitral valve closure, but neither passage identifies a peak of that sound or compares its timing with aortic valve opening. Searches for the first major peak and for aortic valve opening alongside the first heart sound found no such comparison. (LLM, conf=0.75)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935 · see citing works
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775 · see citing works
Relationship between Seismocardiogram and Echocardiogram for Events in the Cardiac Cycle
Crow, R. S., Hannan, P., Jacobs, D., Hedquist, L., & Salerno, D. M. (2017) · American Journal of Noninvasive Cardiology · doi:10.1159/000470156 · Cited by 186 · see citing works
Di Rienzo, M., Vaini, E., Castiglioni, P., Merati, G., Meriggi, P., Parati, G., Faini, A., & Rizzo, F. (2013) · Autonomic Neuroscience · doi:10.1016/j.autneu.2013.04.005 · Cited by 163 · see citing works
Seismocardiography: Past, present and future
Zanetti, J. M., & Tavakolian, K. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6611170 · Cited by 152 · see citing works
Salerno, D. M., & Zanetti, J. M. (1990) · Cited by 123 · see citing works
Seismocardiography: a technique for recording precordial acceleration
Zanetti, J. M., & Salerno, D. M. (2002) · doi:10.1109/cbms.1991.128936 · Cited by 103 · see citing works
Automatic Annotation of Seismocardiogram With High-Frequency Precordial Accelerations
Khosrow-Khavar, F., Tavakolian, K., Blaber, A. P., Zanetti, J. M., Fazel-Rezai, R., & Menon, C. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2360156 · Cited by 91 · see citing works
THE MASS-MOVEMENTS OF THE CIRCULATION AS SHOWN BY A RECOIL CURVE
Henderson, Y. (1905) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1905.14.3.287 · Cited by 74 · see citing works
Seismocardiography: waveform identification and noise analysis
Zanetti, J. M., Poliac, M. O., & Crow, R. S. (2002) · Computers in cardiology · doi:10.1109/cic.1991.169042 · Cited by 62 · see citing works
Yang, C., & Tavassolian, N. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2696703 · Cited by 62 · see citing works
Wilson, R. A., Bamrah, V. S., Lindsay, J., Schwaiger, M., & Morganroth, J. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)90508-a · Cited by 61 · see citing works
A wearable system for the seismocardiogram assessment in daily life conditions
Rienzo, M. D., Meriggi, P., Rizzo, F., Vaini, E., Faini, A., Merati, G., Parati, G., & Castiglioni, P. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091058 · Cited by 61 · see citing works
[Seismocardiography--a new method in the study of functional conditions of the heart].
Bs, B. (1961) · PubMed · Cited by 60 · see citing works
PRAeCORDIAL BALLISTOCARDIOGRAPHY
Mounsey, P. (1957) · Heart · doi:10.1136/hrt.19.2.259 · Cited by 53 · see citing works
Gelaye, B., Sumner, S., McRitchie, S., Carlson, J. E., Ananth, C. V., Enquobahrie, D. A., Qiu, C., Sorensen, T. K., & Williams, M. A. (2016) · PLoS ONE · doi:10.1371/journal.pone.0156755 · Cited by 44 · see citing works
Biering‐Sørensen, T., Møgelvang, R., de Knegt, M. C., Olsen, F. J., Galatius, S., & Jensen, J. S. (2016) · PLoS ONE · doi:10.1371/journal.pone.0153636 · Cited by 40 · see citing works
Acceleration Ballistocardiography
ELLIOTT, R. V., PACKARD, R. G., & Kyrazis, D. T. (1954) · Circulation · doi:10.1161/01.cir.9.2.281 · Cited by 32 · see citing works
Characterization and analysis of seismocardiogram for estimation of hemodynamic parameters
Tavakolian, K. (2010) · Summit (Simon Fraser University) · Cited by 30 · see citing works
Use of seismocardiogram for the beat-to-beat assessment of the Pulse Transit Time: A pilot study
Rienzo, M. D., Vaini, E., & Lombardi, P. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7320049 · Cited by 22 · see citing works
Piras, P., Torromeo, C., Evangelista, A., Gabriele, S., Esposito, G., Nardinocchi, P., Teresi, L., Madeo, A., Schiariti, M. S., Varano, V., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-06189-w · Cited by 19 · see citing works
Piras, P., Torromeo, C., Re, F., Evangelista, A., Gabriele, S., Esposito, G., Nardinocchi, P., Teresi, L., Madeo, A., Chialastri, C., et al. (2016) · Scientific Reports · doi:10.1038/srep34906 · Cited by 14 · see citing works
Challenges in Using Seismocardiography for Blood Pressure Monitoring
S�rensen, K., Verma, A. K., Blaber, A. P., Zanetti, J. M., Schmidt, S. E., Struijk, J. J., & Tavakolian, K. (2017) · Computing in cardiology · doi:10.22489/cinc.2017.026-452 · Cited by 13 · see citing works
Self-citationBAEVSKII, R. M., EGOROV, A. D., & KAZARIAN, L. A. (1996) · PubMed · Cited by 10 · see citing works
Effects of cardiac resynchronization therapy on the first heart sound energy
Jensen, A. S., Schmidt, S. E., Struijk, J. J., Hansen, J., Graff, C., Melgaard, J., Bhuiyan, T. A., Emerek, K. J. G., & Søgaard, P. (2014) · VBN Forskningsportal (Aalborg Universitet) · Cited by 9 · see citing works
Self-citationCardiac-gated Slit Lamp Videography as a Novel Approach to Assessing a Microcirculatory Network
Brennan, P., Finlay, D., Spence, M. S., Awuah, A., McLaughlin, J. A., Moore, J., Nesbit, M. A., Trucco, E., Wang, R., & Moore, T. (2017) · Computing in cardiology · doi:10.22489/cinc.2017.138-248 · Cited by 5 · see citing works
Flagged first, then by citations
1 of the 27 references couldn’t be matched to a known paper.
Research works printed but not linked: 2
- [4]Baevsky R Egorov A Kazarian L Metodika seismokardiografii Kardiologia 1964 18 87 89 14184140
- [24]Otto, Catherine M. Textbook of Clinical Echocardiography: Expert Consult - Online and Print, 4e. (Saunders, 2009).
Cited by
Sorted by citations
Contactless seismocardiography via deep learning radars
Ha, U., Assana, S., & Adib, F. (2020) · ACM Annual International Conference on Mobile Computing and Networking (MobiCom) · doi:10.1145/3372224.3419982 · Cited by 203 · see citing works
Wearable sensors and devices for real-time cardiovascular disease monitoring
Lin, J., Fu, R., Zhong, X., Yu, P., Tan, G., Li, W., Zhang, H., Li, Y., Zhou, L., & Ning, C. (2021) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2021.100541 · Cited by 156 · see citing works
Flexible sensors and machine learning for heart monitoring
Kwon, S. H., & Dong, L. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107632 · Cited by 98 · see citing works
Wearable Sensors for the Monitoring of Maternal Health—A Systematic Review
Alim, A., & Imtiaz, M. H. (2023) · Sensors · doi:10.3390/s23052411 · Cited by 89 · see citing works
Dehkordi, P., Khosrow-Khavar, F., Rienzo, M. D., Inan, O. T., Schmidt, S. E., Blaber, A. P., Sørensen, K., Struijk, J. J., Zakeri, V., Lombardi, P., et al. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01057 · Cited by 82 · see citing works
Self-citationSieciński, S., Kostka, P., & Tkacz, E. (2020) · Sensors · doi:10.3390/s20164522 · Cited by 75 · see citing works
Rai, D., Thakkar, H. K., Rajput, S. S., Santamaría, J., Bhatt, C., & Roca, F. (2021) · Mathematics · doi:10.3390/math9182243 · Cited by 74 · see citing works
Gyrocardiography: A Review of the Definition, History, Waveform Description, and Applications
Sieciński, S., Kostka, P., & Tkacz, E. (2020) · Sensors · doi:10.3390/s20226675 · Cited by 73 · see citing works
Andreozzi, E., Gargiulo, G. D., Esposito, D., & Bifulco, P. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.725716 · Cited by 57 · see citing works
Chest-Worn Inertial Sensors: A Survey of Applications and Methods
Rahmani, M. H., Berkvens, R., & Weyn, M. (2021) · Sensors · doi:10.3390/s21082875 · Cited by 56 · see citing works
Enabling the assessment of trauma-induced hemorrhage via smart wearable systems
Zia, J. S., Kimball, J. P., Rolfes, C., Hahn, J., & Inan, O. T. (2020) · Science Advances · doi:10.1126/sciadv.abb1708 · Cited by 52 · see citing works
CardiacWave: A mmWave-based Scheme of Non-Contact and High-Definition Heart Activity Computing
Xu, C., Li, H., Li, Z., Zhang, H., Rathore, A. S., Chen, X., Wang, K., Huang, M.-C., & Xu, W. (2021) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3478127 · Cited by 49 · see citing works
Santucci, F., Presti, D. L., Massaroni, C., Schena, E., & Setola, R. (2022) · Sensors · doi:10.3390/s22155805 · Cited by 47 · see citing works
Rienzo, M. D., Rizzo, F., Isilay, Z. M., & Lombardi, P. (2020) · Sensors · doi:10.3390/s20030680 · Cited by 44 · see citing works
Bhattacharya, S., Nikbakht, M., Alden, A., Tan, P., Wang, J., Alhalimi, T. A., Kim, S., Wang, P., Tanaka, H., Tandon, A., et al. (2023) · Advanced Electronic Materials · doi:10.1002/aelm.202201284 · Cited by 42 · see citing works
Towards Automatic and Fast Annotation of Seismocardiogram Signals Using Machine Learning
Thakkar, H. K., & Sahoo, P. K. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2951068 · Cited by 41 · see citing works
Reducing the Impact of External Vibrations on Fiducial Point Detection in Seismocardiogram Signals
Lin, D. J., Kimball, J. P., Zia, J. S., Ganti, V. G., & Inan, O. T. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3090376 · Cited by 39 · see citing works
Centracchio, J., Andreozzi, E., Esposito, D., Gargiulo, G. D., & Bifulco, P. (2022) · Bioengineering · doi:10.3390/bioengineering9030089 · Cited by 34 · see citing works
A Clinical Method for Estimation of VO2max Using Seismocardiography
Sørensen, K., Poulsen, M. K., Karbing, D. S., Søgaard, P., Struijk, J. J., & Schmidt, S. E. (2020) · International Journal of Sports Medicine · doi:10.1055/a-1144-3369 · Cited by 31 · see citing works
Self-citationNon-contact heart vibration measurement using computer vision-based seismocardiography
Rahman, M. M., Cook, J., & Taebi, A. (2023) · Scientific Reports · doi:10.1038/s41598-023-38607-7 · Cited by 28 · see citing works
Multichannel seismocardiography: an imaging modality for investigating heart vibrations
Munck, K., Sørensen, K., Struijk, J. J., & Schmidt, S. E. (2020) · Physiological Measurement · doi:10.1088/1361-6579/abc0b7 · Cited by 27 · see citing works
Self-citationSieciński, S., Tkacz, E., & Kostka, P. (2023) · Sensors · doi:10.3390/s23042152 · Cited by 27 · see citing works
A Novel Adaptive Recursive Least Squares Filter to Remove the Motion Artifact in Seismocardiography
Yu, S., & Liu, S. (2020) · Sensors · doi:10.3390/s20061596 · Cited by 27 · see citing works
Respiratory-Induced Amplitude Modulation of Forcecardiography Signals
Centracchio, J., Andreozzi, E., Esposito, D., & Gargiulo, G. D. (2022) · Bioengineering · doi:10.3390/bioengineering9090444 · Cited by 25 · see citing works
Isilay, Z. M., Racca, V., Pezzano, A., Tavanelli, M., & Rienzo, M. D. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.825918 · Cited by 22 · see citing works
Hoffmann, B., Dehkordi, P., Khosrow-Khavar, F., Goswami, N., Blaber, A. P., & Tavakolian, K. (2022) · npj Microgravity · doi:10.1038/s41526-022-00206-7 · Cited by 22 · see citing works
Contactless, Battery-free, and Stretchable Wearable for Continuous Recording of Seismocardiograms
Hesar, M. E., Khan, D., Seyedsadrkhani, N. S., & Ingebrandt, S. (2020) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.0c00768 · Cited by 22 · see citing works
Rienzo, M. D., Avolio, A., Rizzo, G., Zeybek, Z. M. I., & Cucugliato, L. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3101976 · Cited by 21 · see citing works
Real-Time Seismocardiogram Feature Extraction Using Adaptive Gaussian Mixture Models
Lin, D. J., Gazi, A. H., Kimball, J. P., Nikbakht, M. R., & Inan, O. T. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3273989 · Cited by 20 · see citing works
Validity and reliability of seismocardiography for the estimation of cardiorespiratory fitness
Hansen, M. T., Rømer, T., Højgaard, A., Husted, K. L. S., Sørensen, K., Schmidt, S. E., Dela, F., & Helge, J. W. (2023) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2023.08.020 · Cited by 19 · see citing works
Self-citationA Wavelet-Based Approach for Motion Artifact Reduction in Ambulatory Seismocardiography
Skoric, J., D’Mello, Y., & Plant, D. V. (2024) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2024.3368291 · Cited by 20 · see citing works
Identification of Human Breathing-States Using Cardiac-Vibrational Signal for m-Health Applications
Choudhary, T., Sharma, L. N., Bhuyan, M. K., & Bora, K. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3025384 · Cited by 16 · see citing works
Delineation and Analysis of Seismocardiographic Systole and Diastole Profiles
Choudhary, T., Bhuyan, M. K., & Sharma, L. N. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3007295 · Cited by 16 · see citing works
Correlation between diastolic seismocardiography variables and echocardiography variables
Agam, A., Søgaard, P., Kragholm, K. H., Jensen, A. S., Sørensen, K., Hansen, J., & Schmidt, S. E. (2022) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztac043 · Cited by 14 · see citing works
Self-citationTime Domain And Frequency Domain Heart Rate Variability Analysis on Gyrocardiograms
Sieciński, S., Kostka, P., & Tkacz, E. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176052 · Cited by 14 · see citing works
Clustering of SCG Events Using Unsupervised Machine Learning
Gamage, P. T., Azad, M. K., Taebi, A., Sandler, R. H., & Mansy, H. A. (2020) · Springer eBooks · doi:10.1007/978-3-030-36844-9_7 · Cited by 14 · see citing works
M2ECG: Wearable Mechanocardiograms to Electrocardiogram Estimation Using Deep Learning
Tapotee, M. I., Saha, P., Mahmud, S., Alqahtani, A., & Chowdhury, M. E. H. (2024) · IEEE Access · doi:10.1109/access.2024.3353463 · Cited by 13 · see citing works
Morra, S., Hossein, A., Gorlier, D., Rabineau, J., Chaumont, M., Migeotte, P., & van de Borne, P. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab4a6a · Cited by 13 · see citing works
A Unified Methodology for Heartbeats Detection in Seismocardiogram and Ballistocardiogram Signals
Mora, N., Cocconcelli, F., Matrella, G., & Ciampolini, P. (2020) · Computers · doi:10.3390/computers9020041 · Cited by 12 · see citing works
Seismocardiography-based detection of heartbeats for continuous monitoring of vital signs
Cocconcelli, F., Mora, N., Matrella, G., & Ciampolini, P. (2019) · Computer Science and Electronic Engineering Conference · doi:10.1109/ceec47804.2019.8974343 · Cited by 11 · see citing works
Heartbeat Detection in Seismocardiograms with Semantic Segmentation
Duraj, K. M., Sieciński, S., Doniec, R., Piaseczna, N., Kostka, P., & Tkacz, E. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871477 · Cited by 11 · see citing works
Accuracy of a Clinical Applicable Method for Prediction of VO2max Using Seismocardiography
Hansen, M. T., Husted, K. L. S., Fogelstrøm, M., Rømer, T., Schmidt, S. E., Sørensen, K., & Helge, J. W. (2022) · International Journal of Sports Medicine · doi:10.1055/a-2004-4669 · Cited by 10 · see citing works
Self-citationZia, J. S., Kimball, J. P., Rozell, C. J., & Inan, O. T. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3014040 · Cited by 10 · see citing works
Wajdan, A., Jahren, T. S., Villegas-Martínez, M., Khan, F. H., Halvorsen, P. S., Odland, H. H., Elle, O. J., Solberg, A. H. S., & Remme, E. W. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3181148 · Cited by 10 · see citing works
Synthetic seismocardiogram generation using a transformer-based neural network
Nikbakht, M. R., Gazi, A. H., Zia, J. S., An, S., Lin, D. J., Inan, O. T., & Kamaleswaran, R. (2023) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocad067 · Cited by 10 · see citing works
From video to vital signs: a new method for contactless multichannel seismocardiography
Rahman, M. M., Kakavand, B., Wurm, W. V., Holman, W. L., Movahed, M. R., & Taebi, A. (2025) · npj Cardiovascular Health · doi:10.1038/s44325-024-00034-6 · Cited by 9 · see citing works
Analysis of Cardiac Vibration Signals Acquired From a Novel Implant Placed on the Gastric Fundus
Areiza-Laverde, H. J., Dopierala, C., Senhadji, L., Boucher, F. R., Guméry, P.-Y., & Hernandez, A. I. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.748367 · Cited by 9 · see citing works
Sang, B., Shokouhmand, A., Wen, H., Khan, S., Puma, J. A., Patel, A., Green, P., Ebadi, N., & Ayazi, F. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3280407 · Cited by 9 · see citing works
Zhang, L., Cai, P., Deng, Y., Lin, J., Wu, M., Xiao, Z., Chu, Z., Shi, Q., Ye, F., Hu, J., et al. (2021) · Annals of Translational Medicine · doi:10.21037/atm-21-5161 · Cited by 7 · see citing works
Driver Cardiovascular Disease Detection Using Seismocardiogram
Uskovas, G., Valinevičius, A., Žilys, M., Navikas, D., Frivaldský, M., Prauzek, M., Konecny, J., & Andriukaitis, D. (2022) · Electronics · doi:10.3390/electronics11030484 · Cited by 8 · see citing works
Zakeri, V., Tavakolian, K., Blaber, A. P., Bauer, E. P., Dehkordi, P., & Khosrow-Khavar, F. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab6f53 · Cited by 8 · see citing works
Gyrocardiography Unit for Non-Invasive Human Diseases Diagnosis
Михайлович, А. В., Анатольевич, Б. Н., Vyacheslav, U., Gruzevich, Y. K., Комарова, М. Н., Рулев, М. Е., & Evseeva, Y. (2020) · Saint Petersburg International Conference on Integrated Navigation Systems · doi:10.23919/icins43215.2020.9133891 · Cited by 8 · see citing works
Mann, A. J., Rahman, M. M., Vanga, V., Gamage, P. T., & Taebi, A. (2024) · Journal of Medical Devices · doi:10.1115/1.4066368 · Cited by 7 · see citing works
Modeling Consistent Dynamics of Cardiogenic Vibrations in Low-Dimensional Subspace
Zia, J. S., Kimball, J. P., Hersek, S., & Inan, O. T. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2980979 · Cited by 7 · see citing works
Exploring the Impact of Sensor Location on Seismocardiography-Derived Cardiac Time Intervals
Mann, A. J., Gamage, P. T., Kakavand, B., & Taebi, A. (2023) · Journal of Engineering and Science in Medical Diagnostics and Therapy · doi:10.1115/1.4063203 · Cited by 7 · see citing works
CardioID: Secure ECG-BCG Agnostic Interaction-Free Device Pairing
Zuo, S., Sigg, S., Nguyen, L. N., Beck, N., Jähne-Raden, N., & Wolf, M. C. (2022) · IEEE Access · doi:10.1109/access.2022.3226503 · Cited by 6 · see citing works
Seismocardiography and echocardiography: the correlation in the systolic complex
Kolind, C. M., Tange, A. B., Sten, S. T., Sonne, M. M. S., Agam, A., Søgaard, P., & Schmidt, S. E. (2024) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ad6a67 · Cited by 6 · see citing works
Self-citationA Novel Seismocardiogram Mathematical Model for Simplified Adjustment of Adaptive Filter
Uskovas, G., Valinevičius, A., Žilys, M., Navikas, D., Frivaldský, M., Prauzek, M., Konecny, J., & Andriukaitis, D. (2022) · Electronics · doi:10.3390/electronics11152444 · Cited by 6 · see citing works
Comparison of Seismocardiography Based Heart Rate Measurement Method
Erfianto, B., Rizal, A., & Suryani, V. (2020) · Journal of Southwest Jiaotong University · doi:10.35741/issn.0258-2724.55.6.12 · Cited by 5 · see citing works
Seismocardiography as a tool for assessment of bi-ventricular pacing
Sørensen, K., Søgaard, P., Emerek, K. J. G., Jensen, A. S., Struijk, J. J., & Schmidt, S. E. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac94b2 · Cited by 5 · see citing works
Self-citationMechanocardiography detects improvement of systolic function caused by resynchronization pacing
Tokmak, F., Koivisto, T., Lahdenoja, O., Vasankari, T., Jaakkola, S., & Airaksinen, J. K. E. (2023) · Physiological Measurement · doi:10.1088/1361-6579/ad1197 · Cited by 6 · see citing works
Lai, Y.-P., & Zhang, Y. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3412668 · Cited by 5 · see citing works
Agam, A., Agam, A., Korsgaard, E., Haugstrup, T. Y., Kristensen, C. B., Møgelvang, R., Kragholm, K. H., Emerek, K. J. G., Søgaard, P., & Schmidt, S. E. (2025) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztaf037 · Cited by 4 · see citing works
Self-citationYu, S., Xie, A., Liu, Y., Guo, Y., & Wang, G. (2024) · Measurement · doi:10.1016/j.measurement.2024.115942 · Cited by 4 · see citing works
Sieciński, S., & Grzegorzek, M. (2025) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2025.108925 · Cited by 4 · see citing works
Yu, S., Song, Q., & Liu, S. (2020) · IEEE Access · doi:10.1109/access.2020.3013380 · Cited by 4 · see citing works
Rahman, M. M., & Taebi, A. (2023) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn58485.2023.10331617 · Cited by 4 · see citing works
Learning Seismocardiogram Beat Denoising Without Clean Data
Nikbakht, M. R., Lin, D. J., & Inan, O. T. (2023) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi58575.2023.10313428 · Cited by 4 · see citing works
Moscol-Albañil, I., Romano, C., Maiorana, E., Nusca, A., Ussia, G. P., Schena, E., & Massaroni, C. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3619668 · Cited by 3 · see citing works
Estimation of cardiorespiratory fitness in healthy using seismocardiography
Schmidt, S. E., Hansen, M. T., Karbing, D. S., Sørensen, K., Poulsen, M. K., Rømer, T., Struijk, J. J., Søgaard, P., & Helge, J. W. (2025) · npj Cardiovascular Health · doi:10.1038/s44325-025-00053-x · Cited by 3 · see citing works
Self-citationNaufal, D., Pramudyo, M., Rajab, T. L. E., Setiawan, A. W., & Adiono, T. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00235-x · Cited by 3 · see citing works
Electro-Mechanical Data Fusion for Heart Health Monitoring
Yakut, K., Usman, M., Xue, W., Haas, F. M., Hirsh, R. A., Boothby, J., Zhao, X., & Petty, T. (2022) · IEEE International Conference on Healthcare Informatics (ICHI) · doi:10.1109/ichi54592.2022.00057 · Cited by 3 · see citing works
Lee, H. Y., Jung, Y. H., Jeung, K. W., Lee, D. H., Lee, B. K., Jang, G. Y., Oh, T. I., Mamadjonov, N., & Heo, T. (2021) · Resuscitation · doi:10.1016/j.resuscitation.2021.07.009 · Cited by 3 · see citing works
Skoric, J., D’Mello, Y., & Plant, D. V. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3561071 · Cited by 2 · see citing works
Sadhukhan, D., Saloux, É., Hodžić, A., Dorme, C., Fink, M., & Ing, R. K. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3577130 · Cited by 2 · see citing works
Influence of Sampling Frequency on the Symmetric Projection Attractor Reconstruction
Pilar, M. A. I. D., Romano, C., Pinnelli, M., Nusca, A., Ussia, G. P., Schena, E., & Massaroni, C. (2025) · IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT) · doi:10.1109/metroind4.0iot66048.2025.11122086 · Cited by 2 · see citing works
Seismocardiography-based estimation of hemodynamic parameters during submaximal ergometer test
Deoisres, S., Dumnin, S., Yuenyongchaiwat, K., & Thanawattano, C. (2025) · Physiological Measurement · doi:10.1088/1361-6579/ae091a · Cited by 2 · see citing works
Carleton, R. N., Teckchandani, T. A., Neary, J. P., Samayoa, J., Khoury, J. M. B., Maguire, K. Q., Krätzig, G. P., & Asmundson, G. J. G. (2025) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2025.10.044 · Cited by 2 · see citing works
Korsgaard, E., Agam, A., Søgaard, P., Emerek, K. J. G., Sørensen, K., Helge, J. W., Struijk, J. J., & Schmidt, S. E. (2025) · Frontiers in Digital Health · doi:10.3389/fdgth.2025.1699611 · Cited by 2 · see citing works
Self-citationOn the design and development of a handheld electrocardiogram device in a clinical setting
Zepeda-Echavarria, A., Arntz, N. C. M. R., Westra, A. H., van Schelven, L. J., Euwe, F. E., Noordmans, H. J., Vessies, M. B., van de Leur, R. R., Hassink, R. J., Wildbergh, T. X., et al. (2024) · Frontiers in Digital Health · doi:10.3389/fdgth.2024.1403457 · Cited by 2 · see citing works
Real-Time Autoregressive Forecast of Cardiac Features for Psychophysiological Applications
Yaldiz, C. O., Lin, D. J., Gazi, A. H., Cestero, G. I., Chen, C., Bracken, B. K., Winder, A., Lynn, S. K., Sameni, R., & Inan, O. T. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3546148 · Cited by 2 · see citing works
Heart Rate Measurement Based on Embedded Accelerometer in a Smartphone
Urzeniczok, M., Sieciński, S., & Kostka, P. (2022) · Advances in intelligent systems and computing · doi:10.1007/978-3-031-09135-3_37 · Cited by 2 · see citing works
Visualization of the Multichannel Seismocardiogram
Munck, K., Sørensen, K., Struijk, J. J., & Schmidt, S. E. (2019) · Computing in cardiology · doi:10.22489/cinc.2019.204 · Cited by 1 · see citing works
Self-citationChen, C., Lin, W., & Lee, M. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3322675 · Cited by 1 · see citing works
Hu, M., Yi, H., Yan, W., Ren, W., Wang, J., & Qi, F. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.1727160 · Cited by 1 · see citing works
Time Bias Awareness in ECG-Based Multiple Source Data Matching
Albrecht, U., Lawin, D., Kühn, S., & Kulau, U. (2022) · Studies in health technology and informatics · doi:10.3233/shti220668 · Cited by 1 · see citing works
Heart Rate Measuring System using Accelerometer And Gyroscope Sensor in Android Smartphone
Williamsyah, B. M., Rizal, A., Wijaya, R., & Ziani, S. (2024) · International Conference of Science and Information Technology in Smart Administration (ICSINTESA) · doi:10.1109/icsintesa62455.2024.10748185 · Cited by 1 · see citing works
Cordero, R., Feuerstein, D., & Joubert, P.-Y. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.101933 · Cited by 1 · see citing works
Using Seismocardiogram Mathematical Model for Simplified Adjustment of Adaptive Filter
Uskovas, G., & Valinevičius, A. (2022) · International Conference Electronics · doi:10.1109/ieeeconf55059.2022.9810385 · Cited by 1 · see citing works
Seismocardiography: Interpretation and Clinical Application
Sørensen, K. (2021) · doi:10.54337/aau451017905 · Cited by 1 · see citing works
Self-citationVisualization of the Multichannel Seismocardiogram
Munck, K., Struijk, J. J., Sørensen, K., & Schmidt, S. E. (2019) · doi:10.23919/cinc49843.2019.9005739
Self-citationKushagra, A., Dasgupta, U., Roychowdhury, S., Samanta, S., & Srivastava, S. (2022) · AIP Advances · doi:10.1063/5.0076791
Tetlow, N., Devendra, P., Waiting, J. F., Aresu, M., Glover, A., Rooms, M., Jhanji, S., & Milliken, D. (2025) · BJA Open · doi:10.1016/j.bjao.2025.100395
Towards the Design of a Real-Time Processing System for Forcecardiography Signals
Zacharelos, E., Andreozzi, E., Esposito, D., Giaquinto, M., & Napoli, E. (2025) · International Conference on Modern Circuits and Systems Technologies · doi:10.1109/mocast65744.2025.11083939
Hansen, M. T., Jensen, M. H., Nielsen, S. K., Petersen, C. S., Sæderup, R. G., Schmidt, S. E., Wolsk, E., Helge, J. W., & Lamberts, M. (2025) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztaf095
Self-citationEstimation of Cardiorespiratory Fitness in Military Applicants Using Seismocardiography
Rasmussen, L. S., Alstrup, A., Markussen, L., Lamberts, T., Neumann, C., & Lamberts, M. (2025) · Military Medicine · doi:10.1093/milmed/usaf511
Automatic Estimation of Cardiac Time Intervals using Combined SCG and ECG
Ahdy, S., Sandler, R. H., & Mansy, H. A. (2025) · IEEE Signal Processing in Medicine and Biology Symposium · doi:10.1109/spmb67169.2025.11345378
Wearable SENsor to Diagnose and Assess SEverity of Aortic Stenosis (SENSE-AS)
Srinivasan, A., Harake, L. E., Fernandez, E. D. T., Saleeb, J., Trueb, J. T., Flaherty, J. D., Sweis, R. N., Shah, S. J., Thomas, J. D., Narang, A., et al. (2026) · JACC Advances · doi:10.1016/j.jacadv.2026.102699
- Authors
- Sørensen, K., Schmidt, S. E., Jensen, A. S., Søgaard, P., & Struijk, J. J.
- Affiliations
- Aalborg University (DK)
- Aalborg University Hospital (DK)
- Corresponding author
- Sørensen, Kasper
- Venue
- Scientific Reports
- Published
- 2018-10-18
- Volume
- 8
- Issue
- 1
- Pages
- 15455-15455
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC6193995
- OpenAlex
- W2896674935
- Cited by
- 111
- References
- 27
- Citations by year
- 2026: 13 · 2025: 17 · 2024: 8 · 2023: 14 · 2022: 20 · 2021: 11 · 2020: 22 · 2019: 6
- FWCI
- 7.35
- Type
- journal article
- Language
- en
- Update notices
- correction (2020-09-04)
- Open access
- gold
- doi.org
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- VBN Forskningsportal (Aalborg Universitet) (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- seismocardiogram, fiducial points, mitral valve closure, aortic valve closure, valve opening, echocardiography, electrocardiogram
- MeSH terms
- Adult, Aged, Aged, 80 and over, Diastole, Echocardiography, Electrocardiography, Heart Function Tests, Heart Valves, Humans, Image Processing, Computer-Assisted, Middle Aged, Myocardial Contraction, Reference Values, Signal Processing, Computer-Assisted, Systole, Vibration, Reproducibility of Results, Young Adult, Fiducial Markers, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review