FES based tremor suppression using repetitive control
Open accessThe DOI matches its Crossref record; 20 of the 22 references it cites were found in a registry or an index.
Abstract
Tremor is a neurological condition present in half of all multiple sclerosis and Parkinson cases, resulting in involuntary, debilitating movement oscillations. Functional electrical stimulation (FES) can be used to suppress tremor, but current approaches using classical control methods have shown significant limitations. This paper establishes the feasibility of using repetitive control (RC), giving rise to the first FES control structure that embeds learning from experience for the purpose of suppressing tremor. The paradigm is applied to suppress tremor at the wrist via FES regulated co-contraction of wrist extensors/flexors. Experimental evaluation is performed using a validated wrist-rig and results are compared against classical feedback control design to establish the efficacy of the approach.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981 · cited 1×
“Intention tremor is the most frequently diagnosed type of tremor amongst MS patients and usually occurs in the upper limb at a frequency range of 3-5 Hz [2], [3].”
BackgroundThe internal model principle for linear multivariable regulators
Francis, B. A., & Wonham, W. M. (1975) · Applied Mathematics & Optimization · doi:10.1007/bf01447855 · Cited by 1,055
The internal model principle for linear multivariable regulators
Francis, B. A., & Wonham, W. M. (1975) · Applied Mathematics & Optimization · doi:10.1007/bf01448180 · Cited by 874 · cited 1×
“RC design is based on the Internal Model Principle (IMP) developed by [13].”
MethodIterative learning control and repetitive control for engineering practice
Longman, R. W. (2000) · International Journal of Control · doi:10.1080/002071700405905 · Cited by 782 · cited 1×
“Compensator F (z) is chosen to stabilise the closed-loop system [15]–[17].”
BackgroundRepetitive control for systems with uncertain period-time
Steinbuch, M. (2002) · Automatica · doi:10.1016/s0005-1098(02)00134-6 · Cited by 321 · cited 1×
“5, to reproduce the model of the disturbance signal, then it is possible to reject the disturbance signal D(z) from the controlled system and thus a controlled output Y (z) of the system can track the reference signal Yref (z) asymptotically [14].”
BackgroundDesign and implementation of home automation system
Alheraish, A. (2004) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2004.1362503 · Cited by 314
Koch, M., Mostert, J., Heersema, D., & De Keyser, J. (2007) · Journal of Neurology · doi:10.1007/s00415-006-0296-7 · Cited by 184 · cited 2×
“Intention tremor is the most frequently diagnosed type of tremor amongst MS patients and usually occurs in the upper limb at a frequency range of 3-5 Hz [2], [3].”
BackgroundMethods for estimating isometric recruitment curves of electrically stimulated muscle
Durfee, W. K., & MacLean, K. E. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32097 · Cited by 168 · cited 1×
“The former statically maps the level of the electrical stimulation to the isometric muscle torque when the muscle is held at a fixed length [9].”
BackgroundAttenuation of pathological tremors by functional electrical stimulation I: Method
Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150 · cited 1×
“In addition, some feedback systems produce large high-frequency stimulation transients which cause significant discomfort [7].”
BackgroundInvestigation of the Hammerstein hypothesis in the modeling of electrically stimulated muscle
Hunt, K. J., Munih, M., Donaldson, N., & Barr, F. M. D. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.704868 · Cited by 138 · cited 5×
“Then H can be combined with HLAD to form a linear timeinvariant controlled plant P .”
MethodInfluentialIdentification of electrically stimulated muscle models of stroke patients
Le, F., Markovsky, I., Freeman, C. T., & Rogers, E. (2010) · Control Engineering Practice · doi:10.1016/j.conengprac.2009.12.007 · Cited by 125 · cited 1×
“This form of input signal has also been used in [21], and is well-tolerated by participants.”
MethodSelf-citationOn the Theory and Design of Linear Repetitive Control Systemsg
Longman, R. W. (2010) · European Journal of Control · doi:10.3166/ejc.16.447-496 · Cited by 116
Attenuation of pathological tremors by functional electrical stimulation II: Clinical evaluation
Javidan, M., Elek, J., & Prochazka, A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368522 · Cited by 80 · cited 1×
“In [4] conventional filters have been applied in closedloop to suppress tremor at the wrist or elbow joint.”
MethodRepetitive Controller Design Using Optimization in the Frequency Domain
Panomruttanarug, B., & Longman, R. W. (2004) · AIAA/AAS Astrodynamics Specialist Conference and Exhibit · doi:10.2514/6.2004-5299 · Cited by 52 · cited 2×
“The parameter vector can be found by minimising the cost function J = ∑N j=1 FWj F ∗ from 0 up to the Nyquist frequency [16] where F = [1− P (ej )F (ej )] and N is the number of discrete frequencies considered, each denoted as wj , j = 1, · · ·N .”
BackgroundTremor Suppression of Elbow Joint via Functional Electrical Stimulation: A Simulation Study
Zhang, D., & Ang, W. (2006) · 2006 IEEE International Conference on Automation Science and Engineering · doi:10.1109/coase.2006.326877 · Cited by 32 · cited 1×
“In [5], a fuzzy logic controller combined with a ProportionalDerivative (PD) controller was developed.”
MethodColacino, F. M., Rustighi, E., & Mace, B. R. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.08.012 · Cited by 30 · cited 1×
“From [12], it is assumed that FCR and ECR have similar dynamics so HLAD,fcr u HLAD,ecr u HLAD.”
BackgroundCurtin, M., & Lowery, M. M. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-52 · Cited by 26 · cited 1×
“The passive arm is modelled as a rigid body dynamical (RBD) system with linear damping and elastic properties [10], [11].”
BackgroundA Gradient-based Repetitive Control Algorithm Combining ILC and Pole Placement
Hätönen, J., Freeman, C. T., Owens, D. H., Lewin, P. L., & Rogers, E. (2006) · European Journal of Control · doi:10.3166/ejc.12.278-292 · Cited by 18 · cited 3×
“2) Gradient-based RC: An alternative method for designing F (z) is based on a contraction mapping technique in the time domain [18], [19] which satisfies stability and removes the phase shift created by the plant.”
BackgroundMethodSelf-citationBiomechanical Evaluation of an Electric Power-Assisted Bicycle by a Musculoskeletal Model
TAKEHARA, S., Murakami, M., & Kazunori, H. A. S. E. (2012) · Journal of System Design and Dynamics · doi:10.1299/jsdd.6.343 · Cited by 10 · cited 1×
“The passive arm is modelled as a rigid body dynamical (RBD) system with linear damping and elastic properties [10], [11].”
BackgroundOn the use of FES to attenuate tremor by modulating joint impedance
Bó, A. P. L., Coste, C., Poignet, P., Gény, C., & Fattal, C. (2011) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2011.6161352 · Cited by 8 · cited 1×
“In [6], a Proportional-Integral (PI) controller was implemented to alter joint impedance by means of FES to suppress tremor, and modest tremor suppression was achieved.”
Method
Research works printed but not linked: 4
- chen, 2002, Stability issues using FIR filtering in repetitive control, Adv Astronaut Sci, 112, 1321
- 10.1007/bf02368521 · DOI · Paper page
- 2008, Multiple sclerosis resources in the world 2008, World Health Organization and Multiple Sclerosis International Federation Tech Rep
- freriks, 1999, SE-NIAM 8: European Recommendations for Surface ElectroMyoGraphy, Roessingh Res Develop
Cited by
Herrnstadt, G., McKeown, M. J., & Menon, C. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0484-1 · Cited by 30
Voluntary Driven, Velocity Controlled Tremor Suppression
Herrnstadt, G. (2017) · Summit (Simon Fraser University)
Khan, M. R., Saadeh, W., & Altaf, M. A. B. (2021) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs53924.2021.9665556
Higher-Order Repetitive Control Enhanced FES for Wrist Intention Tremor Suppression
Ren, H., Liu, X., Zhang, Z., Duan, R., & Liu, Y. (2025) · Lecture notes in computer science · doi:10.1007/978-981-96-0777-8_3
Metadata
- Authors
- Copur, E. H., Freeman, C., Chu, B., & Laila, D. S.
- Affiliations
- University of Southampton (GB)
- Venue
- 2015 54th IEEE Conference on Decision and Control (CDC)
- Publisher
- IEEE
- Published
- 2015-12
- Volume
- 112
- Pages
- 6023-6028
- ISSN
- 0191-2216 (ISSN-L)
- OpenAlex
- W2240765111
- Cited by
- 4
- References
- 22
- Citations by year
- 2025: 1 · 2021: 1 · 2019: 1 · 2017: 1
- FWCI
- 0.47
- Type
- conference paper
- Language
- en
- Open access
- Licence
- other-oa
- Locations
- IEEE Conference on Decision and Control (CDC) (publishedVersion)
- ePrints Soton (University of Southampton) (acceptedVersion)
- Coventry University Open Collections (Coventry university) (submittedVersion)
- Pure (Coventry University) (submittedVersion, other-oa)
- The Open Collections (Coventry University) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Iterative Learning Control Systems
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- tremor suppression, functional electrical stimulation, repetitive control, Parkinson's disease, multiple sclerosis, learning control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.