The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A database for evaluation of algorithms for measurement of QT and other waveform intervals in the ECG
Abstract
Presents a QT database designed for evaluation of algorithms that detect waveform boundaries in the ECG. The database consists of 105 fifteen-minute excerpts of two-channel ECG Holter recordings, chosen to include a broad variety of QRS and ST-T morphologies. Waveform boundaries for a subset of beats in these recordings have been manually determined by expert annotators using an interactive graphic display to view both signals simultaneously and to insert the annotations. Examples of each morphology were included in this subset of annotated beats; at least 30 beats in each record, 3622 beats in all, were manually annotated in the database. In 11 records, two independent sets of annotations have been included, to allow inter-observer variability studies. The QT Database is available on a CD-ROM in the format previously used for the MIT-BIH Arrhythmia Database and the European ST-T Database, from which some of the recordings in the QT Database have been obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Automatic Detection of Wave Boundaries in Multilead ECG Signals: Validation with the CSE Database
Laguna, P., Jané, R., & Caminal, P. (1994) · Computers and Biomedical Research · doi:10.1006/cbmr.1994.1006 · Cited by 490
Self-citationThe MIT-BIH Arrhythmia Database on CD-ROM and software for use with it
Moody, G. B., & Mark, R. G. (2002) · [1990] Proceedings Computers in Cardiology · doi:10.1109/cic.1990.144205 · Cited by 404
Self-citationDelineation of the QRS complex using the envelope of the e.c.g.
Nygårds, M., & Sörnmo, L. (1983) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442378 · Cited by 139
Cited by
A Wavelet-Based ECG Delineator: Evaluation on Standard Databases
Martinez, J. P., Almeida, R., Olmos, S., Rocha, A. P., & Laguna, P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821031 · Cited by 1,605
Self-citationThe principles of software QRS detection
Kohler, B.-U., Hennig, C., & Orglmeister, R. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.993193 · Cited by 1,242
Chaos as an intermittently forced linear system
Brunton, S. L., Brunton, B. W., Proctor, J. L., Kaiser, E., & Kutz, J. N. (2017) · Nature Communications · doi:10.1038/s41467-017-00030-8 · Cited by 608
Cardiologist-Level Arrhythmia Detection with Convolutional Neural Networks
Rajpurkar, P., Hannun, A., Haghpanahi, M., Bourn, C., & Ng, A. Y. (2017) · arXiv (Cornell University) · doi:10.48550/arxiv.1707.01836 · Cited by 595
Hong, S., Zhou, Y., Shang, J., Xiao, C., & Sun, J. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103801 · Cited by 464
PhysioNet: a Web-based resource for the study of physiologic signals
Moody, G. B., Mark, R. G., & Goldberger, A. L. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932728 · Cited by 386
Self-citationECG Biometric Recognition: A Comparative Analysis
Odinaka, I., Lai, P.-H., Kaplan, A. D., O'Sullivan, J. A., Sirevaag, E. J., & Rohrbaugh, J. W. (2012) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2012.2215324 · Cited by 356
ECG signal analysis through hidden Markov models
Andreao, R. V., Dorizzi, B., & Boudy, J. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.877103 · Cited by 293
Fast QRS Detection with an Optimized Knowledge-Based Method: Evaluation on 11 Standard ECG Databases
Elgendi, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073557 · Cited by 264
Accurate and efficient time-domain classification with adaptive spiking recurrent neural networks
Yin, B., Corradi, F., & Bohté, S. M. (2021) · Nature Machine Intelligence · doi:10.1038/s42256-021-00397-w · Cited by 259
Machine learning in the electrocardiogram
Mincholé, A., Camps, J., Lyon, A., & Rodríguez, B. (2019) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2019.08.008 · Cited by 147
Lanata, A., Guidi, A., Baragli, P., Valenza, G., & Scilingo, E. P. (2015) · PLOS ONE · doi:10.1371/journal.pone.0140783 · Cited by 42
“In order to test the performance of the QRS detection algorithm proposed here, 19 ECG records (Fs = 250Hz) gathered from the human QT database [61, 62] provided by PhysioNet [63] (PN-DB) were used.”
MethodWang, R., Liu, Z., Pang, J., Sun, J., Xiang, M., & Ning, X. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3579060 · Cited by 9
Metadata
- Authors
- Laguna, P., Mark, R. G., Goldberg, A., & Moody, G. B.
- Venue
- Computers in Cardiology 1997
- Publisher
- IEEE
- Published
- 2002-11-22
- Pages
- 673-676
- ISSN
- 0276-6574 (ISSN-L)
- OpenAlex
- W2166704538
- Cited by
- 606
- References
- 3
- FWCI
- 32.90
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.