The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A new QRS detection algorithm based on the Hilbert transform
Abstract
A robust new algorithm for QRS defection using the properties of the Hilbert transform is proposed. The method allows R waves to be differentiated from large, peaked T and P waves with a high degree of accuracy and minimizes the problems associated with baseline drift, motion artifacts and muscular noise. The performance of the algorithm was tested using the records of the MIT-BIH Arrhythmia Database. Beat by beat comparison was performed according to the recommendation of the American National Standard for ambulatory ECG analyzers (ANSI/AAMI EC38-1998). A QRS detection rate of 99.64%, a sensitivity of 99.81% and a positive prediction of 99.83% was achieved against the MIT-BIH Arrhythmia database. The noise tolerance of the new proposed QRS detector was also tested using standard records from the MIT-BIH Noise Stress Test Database. The sensitivity of the detector remains about 94% even for signal-to-noise ratios (SNR) as low as 6 dB.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
A comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043
Cited by
Analysis of First-Derivative Based QRS Detection Algorithms
Arzeno, N. M., Deng, Z.-D., & Poon, C.-S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912658 · Cited by 413
Fast QRS Detection with an Optimized Knowledge-Based Method: Evaluation on 11 Standard ECG Databases
Elgendi, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073557 · Cited by 264
Villarejo, M., Zapirain, B., & Zorrilla, A. (2013) · Sensors · doi:10.3390/s130506141 · Cited by 20
Metadata
- Authors
- Benitez, D. S., Gaydecki, P. A., Zaidi, A., & Fitzpatrick, A. P.
- Venue
- Computers in Cardiology 2000. Vol.27 (Cat. 00CH37163)
- Publisher
- IEEE
- Published
- 2002-11-11
- Pages
- 379-382
- ISSN
- 0276-6574 (ISSN-L)
- OpenAlex
- W2154924564
- Cited by
- 198
- References
- 2
- FWCI
- 5.48
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new QRS detection algorithm based on the Hilbert transform. https://app.cochat.ai/papers/10.1109/cic.2000.898536
- The paper
- Benitez, D. S., Gaydecki, P. A., Zaidi, A., & Fitzpatrick, A. P. (2002). A new QRS detection algorithm based on the Hilbert transform. Computers in Cardiology 2000. Vol.27 (Cat. 00CH37163). https://doi.org/10.1109/cic.2000.898536
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.