256-site active neural probe and 64-channel responsive cortical stimulator
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The 0.35μm CMOS active probe and stimulator enables responsive neural stimulation of the brain cortex. It monitors extracellular neural activity on 256 sites in the brain and generates 64 event-triggered current-mode neural stimuli. Each 0.035mm2fully differential neural recording channel includes a 8-bit single slope ADC. Each 0.02mm2neural stimulation channel reuses an OTA for both current sampling and current sourcing. The 13.5mW prototype is flip-chip bonded with a 64-shank Utah electrode array and validated in spatial recording of epileptic neural activity in the mouse hippocampus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
A Versatile Integrated Circuit for the Acquisition of Biopotentials
Harrison, R. R. (2007) · 2007 IEEE Custom Integrated Circuits Conference · doi:10.1109/cicc.2007.4405694 · Cited by 156
Cited by
A 100-Channel 1-mW Implantable Neural Recording IC
Zou, X., Liu, L., Cheong, J. H., Yao, L., Li, P., Cheng, M.-Y., Goh, W. L., Rajkumar, R., Dawe, G. S., Cheng, K.-W., et al. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2013.2249175 · Cited by 132
Abdelhalim, K., Jafari, H. M., Kokarovtseva, L., Velazquez, J. L. P., & Genov, R. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2272952 · Cited by 124
Self-citationMulti-Channel Neural Recording Implants: A Review
Hashemi Noshahr, F., Nabavi, M., & Sawan, M. (2020) · Sensors · doi:10.3390/s20030904 · Cited by 66
“Another neural recording system with 256 channels is shown in [96].”
BackgroundAl-Ashmouny, K. M., Chang, S.-I., & Yoon, E. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2218105 · Cited by 28
Metadata
- Authors
- Shulyzki, R., Abdelhalim, K., Bagheri, A., Florez, C. M., Carlen, P. L., & Genov, R.
- Venue
- 2011 IEEE Custom Integrated Circuits Conference (CICC)
- Publisher
- IEEE
- Published
- 2011-09
- Pages
- 1-4
- OpenAlex
- W2105958058
- Cited by
- 24
- References
- 2
- FWCI
- 10.91
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 256-site active neural probe and 64-channel responsive cortical stimulator. https://app.cochat.ai/papers/10.1109/cicc.2011.6055371
- The paper
- Shulyzki, R., Abdelhalim, K., Bagheri, A., Florez, C. M., Carlen, P. L., & Genov, R. (2011). 256-site active neural probe and 64-channel responsive cortical stimulator. 2011 IEEE Custom Integrated Circuits Conference (CICC). https://doi.org/10.1109/cicc.2011.6055371
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.