Behavior of a five-phase surface-mounted permanent magnet motor under magnet demagnetization
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The condition monitoring of magnets status in permanent magnet synchronous motors is critical for industrial applications, and then it is receiving more and more attention. Multiphase motor drives are an attractive technology for high power applications. They have many degrees of freedom that can be used for many purposes, such as power density improvement, monitoring, and so on. In this paper, a characterization of rotor faults for five-phase surface-mounted permanent magnet synchronous motors is presented. The considered rotor fault is the demagnetization of the rotor magnet trailing edges, due to large stator currents. The non-invasive detection method is based on a Fourier transform of the back-emf induced in the α-β planes, and exploits the large number of degrees of freedom of a multiphase motor drive. The proposed approach is validated by means of a finite element analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rajagopalan, S., Roux, W. L., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904183 · Cited by 164
Research works printed but not linked: 10
- 10.1109/TPEL.2006.886620 · DOI · Paper page
- haylock, 2006, Predicting and preventing demagnetization in permanent magnet motor drives, Proc Power Electronics Machines and Drives Conf, 474
- 10.1109/TIA.2007.900444 · DOI · Paper page
- 10.1109/ISIE.2008.4677217 · DOI · Paper page
- 10.1109/SLED.2010.5542805 · DOI
- 10.1109/TIA.2004.841021 · DOI · Paper page
- casadei, 2009, Magnets faults characterization for permanent magnet synchronous motors, Proc IEEE International Symposium on Diagnostics for Electric Machines Power Electronics and Drives SDEMPED, 1, 10.1109/DEMPED.2009.5292770 · DOI · Paper page
- 10.1049/iet-epa:20060342 · DOI · Paper page
- 10.1109/IEMDC.2005.195920 · DOI
- 10.1109/IECON.2005.1569139 · DOI · Paper page
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“[97], [98] Zero sequence BEMF component FFT PDF, HS, ON SC, INV, AZP, AOF”
BackgroundMethodFaiz, J., & Mazaheri-Tehrani, E. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2608950 · Cited by 207
Choi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
Detection of magnet demagnetization in five-phase surface-mounted permanent magnet generators
Casadei, D., Filippetti, F., Mengoni, M., Gritli, Y., Serra, G., Tani, A., & Zarri, L. (2012) · 2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2012.6254099 · Cited by 22
Self-citation
Metadata
- Authors
- Casadei, D., Mengoni, M., Serra, G., Tani, A., & Zarri, L.
- Venue
- 8th IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics & Drives
- Publisher
- IEEE
- Published
- 2011-09
- Pages
- 265-271
- OpenAlex
- W1989723878
- Cited by
- 18
- References
- 1
- FWCI
- 2.61
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.