Demagnetization fault detection by means of Hilbert Huang transform of the stator current decomposition in PMSM
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper presents a study of the permanent magnet synchronous motor (PMSM) running under demagnetization. The simulation has been carried out by means of two dimensional (2-D) finite element analysis (FEA), and simulations results were compared with experimental results. The demagnetization fault is analyzed by means of decomposition of stator currents obtained at different speeds for torque change.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines
Rosero, J. A., Cusido, J., Garcia, A., Ortega, J. A., & Romeral, L. (2006) · IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics · doi:10.1109/iecon.2006.347598 · Cited by 67
Self-citation
Research works printed but not linked: 9
- 10.1098/rspa.2003.1123 · DOI · Paper page
- 10.1016/j.ymssp.2005.02.003 · DOI · Paper page
- huang, 1998, the empirical mode decomposition and the hilbert spectrum for nonlinear and non-stationary time series analysis, Proceedings of The Royal Society A Mathematical Physical and Engineering Sciences, 454, 903, 10.1098/rspa.1998.0193 · DOI · Paper page
- 10.1109/MAES.2007.340500 · DOI · Paper page
- 10.1109/TEC.2005.847955 · DOI · Paper page
- 10.1109/ISIE.2007.4375165 · DOI · Paper page
- yuping, 2006, hilbert-huang transform and marginal spectrum for detection of bearing localized defects, Sixth World Congress on Intelligent Control and Automation WCICA, 5457, 10.1109/WCICA.2006.1714115 · DOI
- 10.1109/ISIE.2006.295949 · DOI
- gieras, 2002, Permanent Magnet Motor Technology Design and Applications
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Moosavi, S. S., Djerdir, A., Amirat, Y. A., & Khaburi, D. A. (2015) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2015.04.062 · Cited by 96
Bhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
“7 Three-phase inverter topology for PMSMs[75] 4.”
MethodInfluentialA review of Permanent Magnet Synchronous Motor fault diagnosis
ZhifuWang, Yang, J., Ye, H., & Zhou, W. (2014) · 2014 IEEE Conference and Expo Transportation Electrification Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itec-ap.2014.6940870 · Cited by 62
Quality Assurance Testing for Magnetization Quality Assessment of BLDC Motors Used in Compressors
Lee, K.-W., Hong, J., Lee, S. B., & Lee, S. (2010) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2075732 · Cited by 27
Metadata
- Authors
- Rosero, J., Romeral, L., Ortega, J. A., & Urresty, J. C.
- Venue
- 2008 IEEE International Symposium on Industrial Electronics
- Publisher
- IEEE
- Published
- 2008-06
- Pages
- 172-177
- OpenAlex
- W2144376441
- Cited by
- 61
- References
- 1
- FWCI
- 8.53
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Demagnetization fault detection by means of Hilbert Huang transform of the stator current decomposition in PMSM. https://app.cochat.ai/papers/10.1109/isie.2008.4677217
- The paper
- Rosero, J., Romeral, L., Ortega, J. A., & Urresty, J. C. (2008). Demagnetization fault detection by means of Hilbert Huang transform of the stator current decomposition in PMSM. 2008 IEEE International Symposium on Industrial Electronics. https://doi.org/10.1109/isie.2008.4677217
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.