Fault detection and classification in permanent magnet synchronous machines using Fast Fourier Transform and Linear Discriminant Analysis
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
The main objective of this paper is to propose a method to detect the presence of a fault in Permanent Magnet Synchronous Machines (PMSMs), determine the type of that fault and estimate the severity in the case of eccentricity fault. In this paper, three types of faults are discussed: static eccentricity, inter-turn short circuit, and demagnetization faults. The machine is controlled using a three phase current source and the harmonics of the stator voltage are used as detailed features for the classifier for fault detection. Two dimensional (2-D) Finite Element Analysis (FEA) is used to model and simulate the machine under healthy and faulty conditions. Fast Fourier Transform (FFT) analysis is performed to the phase voltage signal to detect the frequency spectrum and Linear Discriminant Analysis (LDA) is chosen as a classification method. To validate the method, two different types of PMSMs are tested: the first with a concentrated winding and the second with a series distributed winding. The tests are applied for different operation loads.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“According to [40], the frequency components, the amplitudes of which increase as a result of the failure of the stator winding, are calculated as follows:”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [40]
Citations
Cites
Permanent magnet motor technology : design and applications
Gieras, J. F., & Wing, M. (1996) · Thammasat University Digital Collections · Cited by 746
Classification, estimation, and pattern recognition
Young, T. Y., & Calvert, T. W. (1974) · International Linear Collider · Cited by 332
Espinosa, A. G., Rosero, J. A., Cusido, J., Romeral, L., & Ortega, J. A. (2010) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2009.2037922 · Cited by 243
Hong, J., Park, S., Hyun, D., Kang, T.-J., Lee, S. B., Kral, C., & Haumer, A. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2191253 · Cited by 219
Ebrahimi, B. M., & Faiz, J. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2050496 · Cited by 208
Thomson, W. T., & Barbour, A. (1998) · IEEE Transactions on Energy Conversion · doi:10.1109/60.736320 · Cited by 173
Briz, F., Degner, M. W., Zamarrón, A., & Guerrero, J. M. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.813746 · Cited by 132
Torkaman, H., Afjei, E. S., & Yadegari, P. (2012) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2191619 · Cited by 79
Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines
Rosero, J. A., Cusido, J., Garcia, A., Ortega, J. A., & Romeral, L. (2006) · IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics · doi:10.1109/iecon.2006.347598 · Cited by 67
The Internal Fault Analysis of Brushless DC Motors Based on the Winding Function Theory
Kim, T., Lee, H.-W., & Kwak, S. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2013246 · Cited by 65
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“According to [40], the frequency components, the amplitudes of which increase as a result of the failure of the stator winding, are calculated as follows:”
BackgroundChen, S., Yu, J., & Wang, S. (2020) · Journal of Process Control · doi:10.1016/j.jprocont.2020.01.004 · Cited by 189
Haddad, R. Z., & Strangas, E. G. (2016) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2016.2558183 · Cited by 158
“Here, we continue the work of [3].”
Self-citationDiscernment of Broken Magnet and Static Eccentricity Faults in Permanent Magnet Synchronous Motors
Goktas, T., Zafarani, M., & Akin, B. (2016) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2015.2512602 · Cited by 140
“The phase voltages to detect and classify the demagnetization and eccentricity faults [12] and the zero-sequence component of the phase voltages [13] to detect demagnetization fault are be used in PMSMs.”
MethodGomathy, V., & Selvaperumal, S. (2016) · Journal of Power Electronics · doi:10.6113/jpe.2016.16.3.1097 · Cited by 53
Obeid, N. H., Boileau, T., & Nahid-Mobarakeh, B. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2581760 · Cited by 52
“These detection techniques are in time domain [20], frequency domain [21], [22], or time–frequency domain [23], [24].”
BackgroundBouzid, M. B. K., & Champenois, G. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2661841 · Cited by 41
“transform (FFT)] [20], and classical time–frequency analysis methods (e.”
MethodPietrzak, P., & Wolkiewicz, M. (2021) · Energies · doi:10.3390/en14061630 · Cited by 40
“According to [37], the amplitude of the frequency components described by Equation (1) may also increase.”
BackgroundAggarwal, A., Allafi, I. M., Strangas, E. G., & Agapiou, J. S. (2020) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2020.3006016 · Cited by 39
“In [6], harmonics in the voltage signal, which are capable of fault separation in the current-controlled machine, were used as an indicator for detection.”
Self-citationPietrzak, P., & Wolkiewicz, M. (2023) · Electronics · doi:10.3390/electronics12071543 · Cited by 33
Modeling and detection of the short-circuit fault in PMSM using Finite Element Analysis
Fitouri, M., Bensalem, Y., & Abdelkrim, M. N. (2016) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2016.07.769 · Cited by 29
Outer race bearing fault detection in induction machines using stator current signals
Haddad, R. Z., Lopez, C. A., Pons-Llinares, J., Daviu, J. A. A., & Strangas, E. G. (2015) · IEEE International Conference on Industrial Informatics (INDIN) · doi:10.1109/indin.2015.7281839 · Cited by 27
Self-citationReview of Detection Methods of Static Eccentricity for Interior Permanent Magnet Synchronous Machine
Aggarwal, A., & Strangas, E. G. (2019) · Energies · doi:10.3390/en12214105 · Cited by 27
“Harmonics in Voltage and Current Signals This work expands on [15] to detect static eccentricity fault.”
BackgroundMethodSelf-citationFoster, S. N., Cintron-Rivera, J. G., & Strangas, E. G. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2015.10.021 · Cited by 25
Self-citationHaddad, R. Z., & Strangas, E. G. (2015) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2015.7303702 · Cited by 20
“In previous work [12], the MCSA and Linear Discriminant Analysis evaluated the accuracy to detect the type of the different faults (eccentricity, turn-to-turn short circuit and demagnetization) and estimate its severity, it was shown that the change in the stator current or voltages harmonics amplitude due to the diff…”
MethodSelf-citationPWM Ripple Currents Based Turn Fault Detection for Multiphase Permanent Magnet Machines
Hu, R., Wang, J., Sen, B., Mills, A. R., Chong, E., & Sun, Z. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2642193 · Cited by 19
“When an inter-turn fault occurs, excessively high current will circulate in the shorted turns and increase the winding temperature to a level where severe damage or even breakdown f the whole insulation occurs [7] .”
BackgroundNavarro-Navarro, Á., Ruiz-Sarrio, J. E., Biot-Monterde, V., Daviu, J. A. A., Becker, V., & Urschel, S. (2023) · Machines · doi:10.3390/machines11020288 · Cited by 17
Obeid, N. H., Boileau, T., & Nahid‐Mobarakeh, B. (2015) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2015.7356845 · Cited by 17
“These detection techniques are in time domain [19], frequency domain [20], [21] or both for a higher degree of efficiency and accuracy.”
BackgroundDiagnosis and discernment between eccentricity and demagnetization faults in PMSM drives
Koura, M. B., Boudinar, A. H., Aimer, A. F., Bendiabdellah, A., & Gherabi, Z. (2021) · Journal of Power Electronics · doi:10.1007/s43236-020-00204-6 · Cited by 15
“In addition, this technique has another drawback relating to the signatures of demagnetization and eccentricity faults since they occur at the same frequency locations [13, 14].”
MethodResultDetection of Demagnetization Faults in Axial Flux Permanent-Magnet Synchronous Wind Generators
Lamprokostopoulos, A., Mitronikas, E. D., & Barmpatza, A. C. (2022) · Energies · doi:10.3390/en15093220 · Cited by 14
Robust Voltage based Technique for Automatic Off-Line Detection of Static Eccentricity of PMSM
Aggarwal, A., Strangas, E. G., & Agapiou, J. (2019) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2019.8785186 · Cited by 13
“Fault separation based on the harmonics in current and voltage is discussed in [8] and [9].”
BackgroundSelf-citationAggarwal, A., Strangas, E. G., & Agapiou, J. (2019) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2019.8864908 · Cited by 11
“This work expands on [7] to detect static eccentricity fault.”
BackgroundMethodSelf-citationFailure Detection by Signal Similarity Measurement of Brushless DC Motors
Fico, V. M., Vázquez, A. L. R., Martín-Prats, M. A., & Zazzera, F. B. (2019) · Energies · doi:10.3390/en12071364 · Cited by 13
Numerical Modeling of Brushless Synchronous Generator for Rectifier Fault detection
Rahnama, M., Vahedi, A., Mohammad‐Alikhani, A., & Nobahari, A. (2019) · International Symposium on Electromagnetic Fields in Mechatronics, Electrical and Electronic Engineering (ISEF) · doi:10.1109/isef45929.2019.9097020 · Cited by 9
“Twodimensional finite element analysis is used to model and simulate the healthy and faulty states of the permanent magnet synchronous machine in [4] to be used for evaluating the proposed fault detection method.”
MethodA Review of Fault Diagnosis Methods of Robot Joint Servo System
Wu, H. Q., & Feng, J. (2020) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma49215.2020.9233583 · Cited by 13
Linear discriminant analysis for an automatic detection of stator faults in induction motor drives
Frosini, L., Zanazzo, S., & Beccarisi, F. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062402 · Cited by 8
“In [13] the data sets are obtained by means of simulation with FLUX-2D, but considering two types of PMSM (one with concentrated winding and one with distributed winding), three types of fault (static eccentricity, inter-turn short circuits, demagnetization) and verifying the possibility both to detect the fault and t…”
MethodInfluentialHarmouche, J. (2014) · theses.fr (ABES) · doi:10.70675/a63096c8z22f9z468ez897bz0ab2ed9d82cf · Cited by 7
Shih, K., Ngo, D., Huang, S., & Hsieh, M. (2025) · IET Electric Power Applications · doi:10.1049/elp2.70081 · Cited by 6
Yoo, J.-H., Hwang, D.-H., & Jung, T.-U. (2015) · IEEE Vehicle Power and Propulsion Conference (VPPC) · doi:10.1109/vppc.2015.7352971 · Cited by 5
“Whereas, when the motor is operating, the demagnetization of PM can be detected by using the spectrum of stator current [1-6].”
BackgroundA voltage based approach for fault detection and separation in permanent magnet synchronous machines
Haddad, R. Z., Lopez, C. A., Foster, S. N., & Strangas, E. G. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7854806 · Cited by 6
“In [15], MSCA and Linear”
Self-citationSalem, F. B. (2020) · IntechOpen eBooks · doi:10.5772/intechopen.88784 · Cited by 5
Modelling. Simulation and Early Diagnosis of PMSM Demagnetization Fault
Singh, M., Dubey, G., Gupta, D., Siddiqui, K. M., & Chauhan, B. K. (2022) · International Conference on Sustainable Technology for Power and Energy Systems (STPES) · doi:10.1109/stpes54845.2022.10006542 · Cited by 4
“In the past, different techniques have been used such as predictive direct torque control, non-linear torque control, field oriented control and also many estimation techniques such as flux vector and speed [5-6].”
MethodJarosz, J. J., Skowron, M., Frankiewicz, O., Wolkiewicz, M., Weisse, S., Valire, J., & Szabat, K. (2025) · Electronics · doi:10.3390/electronics14122373 · Cited by 4
Detection of Rotor Faults in Salient Pole Generator Using Flux Density Monitoring
Ployard, M., Fasquelle, A., Tounzi, A., & Gillon, F. (2020) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icem49940.2020.9270964 · Cited by 4
“As mentioned in [8], the distinction between healthy and faulty PSD can be difficult to evaluate.”
BackgroundPietrzak, P., Wolkiewicz, M., & Kotarski, J. (2024) · Electronics · doi:10.3390/electronics13152975 · Cited by 3
Fico, V. M., Martín-Prats, M. A., & Ierardi, C. (2020) · Energies · doi:10.3390/en13071573 · Cited by 3
“[9] Y Y P Y 3 Journal [10] Y P Y Y 12 Journal [11] Y Y Y Y 5 Journal [12] Y P Y P 1 Journal [1] Y Y Y Y 3 Journal [13] Y Y P P 1 Journal [14] Y Y Y Y 2 Conference [15] P Y Y P 1 Conference [16] Y Y Y Y 1 Journal [17] Y Y P P 0 Conference [18] Y P P P 0 Conference [19] Y P Y Y 1 Conference [20] Y Y Y Y 13 Journal [21]…”
MethodDiagnosis of brushless synchronous generator using numerical modeling
Rahnama, M., Vahedi, A., Mohammad‐Alikhani, A., & Takorabet, N. (2020) · COMPEL The International Journal for Computation and Mathematics in Electrical and Electronic Engineering · doi:10.1108/compel-01-2020-0018 · Cited by 2
Inter-turn short-circuit fault detection in the vectorial control PMSM drive
Sdiri, F., Bensalem, Y., Trabelsi, H., & Abdelkrim, M. N. (2017) · International Conference on Sciences and Techniques of Automatic Control and Computer Engineering · doi:10.1109/sta.2017.8314960 · Cited by 2
“In [7], a fault detection and classification in PMSM based on Fast Fourier Transform and linear discriminant analysis is done.”
MethodYoo, J.-H., Park, C.-S., & Jung, T.-U. (2015) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2015.7385275 · Cited by 1
Detection of Eccentricity Faults in air-cored C-GEN PM Machines for Wind Turbine
Rasid, S., Lian, X., Mueller, M. A., & Gyftakis, K. N. (2021) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/sdemped51010.2021.9605529 · Cited by 1
Demagnetization Fault Diagnosis of a PMSG Based on Instantaneous Power Signatures
Lamprokostopoulos, A., & Mitronikas, E. D. (2022) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icem51905.2022.9910634 · Cited by 1
Model-based diagnosis and prognosis of induction motors under stator winding fault
Nguyen, V. H. (2018) · doi:10.32657/10220/46022 · Cited by 1
“FFT combined with Linear Discriminant Analysis is proposed in [110].”
MethodDiagnostic des machines électriques par fusion d'informations
Irhoumah, M. (2019) · theses.fr (ABES) · doi:10.70675/b52bd528z52bbz4111zab69zedeeb3471911 · Cited by 3
Locating Faulty Section in Tie-line Using Classification Based Methods
Patel, V. S., Kapoor, A., Sharma, A. K., & Chakrabarti, S. (2022) · IEEE PES Innovative Smart Grid Technologies - Asia (ISGT Asia) · doi:10.1109/isgtasia54193.2022.10003564
“The LDA is utilized in [12] to detect the type and severity of the faults by using the harmonics in the phase voltage as a feature for classification.”
MethodChapagain, A., Melfald, E. G., Johannesen, N. J., & Silwal, B. (2024) · International Conference on Power System Technology (POWERCON) · doi:10.1109/powercon60995.2024.10870525
“D FEA was used and validated with Linear Discriminant Analysis in [5] to detect, classify, and estimate the severity of faults in Permanent Magnet Synchronous Machines (PMSM), using stator voltage harmonics as features for a classifier with different winding configurations under various loads.”
Towards Quantitative Eccentricity Fault Modeling for Interior Permanent Magnet Motors
Erfanimatin, M., & Zhou, L. (2025) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce58356.2025.11259861
“Haddad et al. [5] introduced a method based on Fast Fourier Transform (FFT) analysis of the phase voltage signal in PMSMs to determine the type of different faults, including static eccentricity, and to estimate its severity.”
Aubert, B. (2014) · theses.fr (ABES) · doi:10.70675/60607a8ez3440z47b2z8eadz6e6d37265478 · Cited by 6
Advanced Artificial Intelligence for Fault Detection of Electric Motors
Guidotti, G., Zettin, P., Ballo, F. M., & Gobbi, M. (2026) · Electronics · doi:10.3390/electronics15153424
Metadata
- Authors
- Haddad, R. Z., & Strangas, E. G.
- Affiliations
- Michigan State University (US)
- Venue
- 2013 9th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives (SDEMPED)
- Publisher
- IEEE
- Published
- 2013-08
- Pages
- 99-104
- OpenAlex
- W1971826559
- Cited by
- 46
- References
- 15
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 2 · 2023: 2 · 2022: 5 · 2021: 3 · 2020: 7 · 2019: 6 · 2018: 1 · 2017: 3 · 2016: 7 · 2015: 7
- FWCI
- 6.37
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet synchronous motor, fault detection, fault classification, static eccentricity, inter-turn short circuit, demagnetization, linear discriminant analysis, fast Fourier transform, fault severity estimation, concentrated winding, distributed winding, finite element analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.