CoChat

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

On the Accuracy of Fault Detection and Separation in Permanent Magnet Synchronous Machines Using MCSA/MVSA and LDA

Haddad, Reemon Z., Strangas, Elias G. · 2016 · IEEE Transactions on Energy Conversion

Abstract

In this paper, the motor current/voltage signature analysis and linear discriminant analysis (LDA) are evaluated with respect to the accuracy to detect the status of permanent magnet synchronous machines (PMSMs) whether it is healthy or faulted, determine the type of that fault, and estimate the severity in the case of static eccentricity or turn-to-turn short-circuit fault. Three types of faults are discussed: static eccentricity, turn-to-turn short circuit, and partial demagnetization fault. Two-dimensional finite element analysis (FEA) is used to model and simulate the machine under healthy and faulted conditions. Fast Fourier transform is applied to the phase voltage or current signals to obtain the frequency spectrum. A combination of the amplitude of the harmonics of the stator voltage or current signals are used as detailed features for the classifier for fault detection. LDA is chosen as a classification method for both detecting the fault and estimating its severity. Two different winding types of PMSMs are tested: a concentrated and a distributed winding machine. To validate the simulation results, experiments at different operational points are carried out and the results are compared with the sFEA.

Overview

Integrity signals

Registry

Crossref · 10.1109/tec.2016.2558183

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 27 references

Research works printed but not linked: 2

  1. roux, 0, Rotor fault analysis of a permanent magnet synchronous machine, Proc 15th Int Conf Electr Mach
  2. rosero, 0, On-line condition monitoring technique for PMSM perated with eccentricity, Proc IEEE Int Symp Diag Electr Mach Power Electron Drives, 95

Cited by

See all 162

Metadata

Authors
Haddad, R. Z., & Strangas, E. G.
Affiliations
Michigan State University (US)
Venue
IEEE Transactions on Energy Conversion
Published
2016-09
Volume
31
Issue
3
Pages
924-934
ISSN
  • 0885-8969 (ISSN-L)
  • 1558-0059
OpenAlex
W2343408121
Cited by
158
References
27
Citations by year
2026: 8 · 2025: 18 · 2024: 14 · 2023: 22 · 2022: 25 · 2021: 22 · 2020: 20 · 2019: 13 · 2018: 9 · 2017: 7
FWCI
8.13
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Energy Conversion (publishedVersion)
Funders
  • National Science Foundation (ECCS1102316)
  • Jordan University of Science and Technology (TEC-00317-2015)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
Keywords
permanent magnet synchronous motor, fault detection, fault classification, linear discriminant analysis, motor current signature analysis, static eccentricity, turn-to-turn short circuit, partial demagnetization, fault severity estimation, concentrated winding, distributed winding, harmonic characteristics, finite element analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: On the Accuracy of Fault Detection and Separation in Permanent Magnet Synchronous Machines Using MCSA/MVSA and LDA. https://app.cochat.ai/papers/10.1109/tec.2016.2558183
The paper
Haddad, R. Z., & Strangas, E. G. (2016). On the Accuracy of Fault Detection and Separation in Permanent Magnet Synchronous Machines Using MCSA/MVSA and LDA. IEEE Transactions on Energy Conversion. https://doi.org/10.1109/tec.2016.2558183

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.