A 232-channel retinal vision prosthesis with a miniaturized hermetic package
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Miniaturization of implantable devices while drastically increasing the number of stimulation channels is one of the greatest challenges in implant manufacturing because a small but hermetic package is needed that provides reliable protection for the electronics over decades. Retinal vision prostheses are the best example for it. This paper presents a miniaturized 232-channel vision prosthesis, summarizing the studies on the individual technologies that were developed, improved and combined to fabricate a telemetrically powered retinal device sample. The implantable unit, which is made out of a high temperature co-fired alumina ceramic package containing hermetic feedthroughs, electronic circuitry and a radio frequency coil for powering is manufactured through a modified screen-printing/lasering process. The package is sealed with solder glass to provide unaffected inductive coupling to the telemetric transmitter. A 0.05 cc inner volume allows helium leak testing and mathematical lifetime estimations for moisture-induced failure of up to 100 years. The feedthroughs contact a thin-film polyimide electrode array that utilizes DLC and SiC coatings for improved interlayer adhesion of the metallic tracks to the polymer carrier. Two metal layers allow integrated wiring of the electrode array within the very limited space.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noorsal, E., Sooksood, K., Xu, H., Hornig, R., Becker, J., & Ortmanns, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2164667 · Cited by 212
Self-citation
Cited by
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Stoecklin, S., Rosch, E., Yousaf, A., & Reindl, L. (2020) · Sensors · doi:10.3390/s20216025 · Cited by 12
Čvančara, P., Valle, G., Müller, M., Guiho, T., Hiairrassary, A., Petrini, F., Raspopovic, S., Strauss, I., Granata, G., Fernandez, E., et al. (2019) · doi:10.1101/653964 · Cited by 12
Self-citationImplantable Device Fabrication and Packaging
Stieglitz, T. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_102 · Cited by 7
Self-citationCapacitive feedthroughs for medical implants
Grob, S., Tass, P. A., & Hauptmann, C. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00404 · Cited by 3
“Sapiens Steering Brain Stimulation (Eindhoven, Netherlands) published an electrode containing even 32 contacts (Contarino et al., 2014).”
Background
Metadata
- Authors
- Ordonez, J. S., Schuettler, M., Ortmanns, M., & Stieglitz, T.
- Venue
- 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2012-08
- Volume
- 2012
- Pages
- 2796-2799
- OpenAlex
- W2038607835
- Cited by
- 28
- References
- 1
- FWCI
- 8.58
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A 232-channel retinal vision prosthesis with a miniaturized hermetic package. https://app.cochat.ai/papers/10.1109/embc.2012.6346545
- The paper
- Ordonez, J. S., Schuettler, M., Ortmanns, M., & Stieglitz, T. (2012). A 232-channel retinal vision prosthesis with a miniaturized hermetic package. 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/embc.2012.6346545
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.