Very High Bit Rate Near-Field Communication with Low-Interference Coils and Digital Single-Bit Sampling Transceivers for Biomedical Sensor Systems
Open accessThe DOI matches its Crossref record; 32 of the 34 references it cites were found in a registry or an index.
Abstract
The evolution of microelectronics increased the information acquired by today’s biomedical sensor systems to an extent where the capacity of low-power communication interfaces becomes one of the central bottlenecks. Hence, this paper mathematically analyzes and experimentally verifies novel coil and transceiver topologies for near-field communication interfaces, which simultaneously allow for high data transfer rates, low power consumption, and reduced interference to nearby wireless power transfer interfaces. Data coil design is focused on presenting two particular topologies which provide sufficient coupling between a reader and a wireless sensor system, but do not couple to an energy coil situated on the same substrate, severely reducing interference between wireless data and energy transfer interfaces. A novel transceiver design combines the approaches of a minimalistic analog front-end with a fully digital single-bit sampling demodulator, in which rectangular binary signals are processed by simple digital circuits instead of sinusoidal signals being conditioned by complex analog mixers and subsequent multi-bit analog-to-digital converters. The concepts are implemented using an analog interface in discrete circuit technology and a commercial low-power field-programmable gate array, yielding a transceiver which supports data rates of up to 6.78 MBit/s with an energy consumption of just 646 pJ/bit in transmitting mode and of 364 pJ/bit in receiving mode at a bit error rate of 2×10−7, being 10 times more energy efficient than any commercial NFC interface and fully implementable without any custom CMOS technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


![Figure 3 Data coil topologies to minimize mutual inductance to an energy coil on the same substrate and magnetic flux density distribution Bz of a planar spiral coil from [28]. By incorporating flux components of opposite sign, the effective flux in the data coil structure can be minimized. Zero coupling can be achieved by appropriate selection of rc2,i and sb,i.](https://figures.cochat.ai/paper-figures/7b9bfdf9ac784427ac225b2aa923fb5b/very-high-bit-rate-near-field-communication-with-low-interference-coils-and-figure-3.jpg)






















Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This dual functionality for both power transfer and data exchange at close proximity makes NFC a versatile choice for neural implant systems, serving specific purposes that broader inductive coupling technologies might not fulfill (Stoecklin et al., 2020; Lathiya and Wang, 2021; Van Mulders et al., 2022).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Stoecklin et al., 2020
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Moreover, NFC’s capability to support two-way data communication between an external coil or loop antenna and a second implanted coil, while penetrating the tissue barrier, further sets it apart.”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Stoecklin et al., 2020
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“This specialized design results in NFC devices generating weaker electromagnetic fields compared to broader RF technologies, whose radiation levels vary based on power and application (Stoecklin et al., 2020; Lathiya and Wang, 2021; Van Mulders et al., 2022).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Stoecklin et al., 2020
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Finkenzeller, K. (2010) · doi:10.1002/9780470665121 · Cited by 1,428
Inductance Calculations in a Complex Integrated Circuit Environment
Ruehli, A. E. (1972) · IBM Journal of Research and Development · doi:10.1147/rd.165.0470 · Cited by 1,038
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878 · cited 1×
“Among others, inductive communication technologies have been applied in biomedical sensor systems to monitor physiological parameters such as heart rate, blood pressure, or gastrointestinal activity [1,2], to analyze biochemical fluids [3,4], to improve hearing in cochlear implants [5], to reestablish vision in retina…”
BackgroundContact Lens Sensors in Ocular Diagnostics
Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400504 · Cited by 466
Toward Flexible and Wearable Human‐Interactive Health‐Monitoring Devices
Takei, K., Honda, W., Harada, S., Arie, T., & Akita, S. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400546 · Cited by 371
Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments
Jow, U.-M., & Ghovanloo, M. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2025366 · Cited by 241
A Neural Probe With Up to 966 Electrodes and Up to 384 Configurable Channels in 0.13 $\mu$m SOI CMOS
Mora Lopez, C., Putzeys, J., Raducanu, B. C., Ballini, M., Wang, S., Andrei, A., Rochus, V., Vandebriel, R., Severi, S., Van Hoof, C., et al. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2646901 · Cited by 201
High-Speed OQPSK and Efficient Power Transfer Through Inductive Link for Biomedical Implants
Simard, G., Sawan, M., & Massicotte, D. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2039212 · Cited by 193
Wireless Neurosensor for Full-Spectrum Electrophysiology Recordings during Free Behavior
Yin, M., Borton, D. A., Komar, J., Agha, N., Lu, Y., Li, H., Laurens, J., Lang, Y., Li, Q., Bull, C., et al. (2014) · Neuron · doi:10.1016/j.neuron.2014.11.010 · Cited by 175
Rail-to-Rail-Input Dual-Radio 64-Channel Closed-Loop Neurostimulator
Kassiri, H., Salam, M. T., Pazhouhandeh, M. R., Soltani, N., Perez Velazquez, J. L., Carlen, P., & Genov, R. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2749426 · Cited by 160
Research works printed but not linked: 2
- Rozgic, 2019, A 0.338 cm3, Artifact-Free, 64-Contact Neuromodulation Platform for Simultaneous Stimulation and Sensing, IEEE Trans. Biomed. Circuits Syst., 13, 38
- Pozar, D. (2012). Microwave Engineering, John Wiley & Sons. [4th ed.].
Cited by
Comparative analysis of energy transfer mechanisms for neural implants
Miziev, S., Pawlak, W. A., & Howard, N. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1320441 · Cited by 21
Novel Resonance-Based Wireless Power Transfer Using Mixed Coupling
Park, S.-W., & Ahn, S. (2020) · Sensors · doi:10.3390/s20247277 · Cited by 10
Stoecklin, S., Yousaf, A., Gidion, G., Reindl, L. M., & Rupitsch, S. J. (2021) · Sensors · doi:10.3390/s21062023 · Cited by 10
Self-citationA Multilevel Synchronized Optical Pulsed Modulation for High Efficiency Biotelemetry
Stanchieri, G. D. P., Marcellis, A. D., Battisti, G., Faccio, M., Palange, E., & Constandinou, T. G. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3209542 · Cited by 9
A 0.18 μm CMOS Integrated Optical Wireless Power Transfer System for Implantable Biomedical Devices
Stanchieri, G. D. P., Marcellis, A. D., Faccio, M., Palange, E., & Güler, Ü. (2023) · International Conference Mixed Design of Integrated Circuits and Systems · doi:10.23919/mixdes58562.2023.10203250 · Cited by 7
Metadata
- Authors
- Stoecklin, S., Rosch, E., Yousaf, A., & Reindl, L.
- Affiliations
- University of Freiburg (DE)
- Corresponding author
- Stoecklin, Sebastian
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-10-23
- Volume
- 20
- Issue
- 21
- Pages
- 6025
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC7660340
- OpenAlex
- W3094138147
- Cited by
- 12
- References
- 34
- Citations by year
- 2025: 2 · 2024: 4 · 2023: 2 · 2022: 2 · 2021: 1 · 2020: 1
- FWCI
- 0.51
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Fritz Huettinger Stiftung (Fritz Huettinger-Stipendium)
- Deutsche Forschungsgemeinschaft (EXC1086)
- Albert-Ludwigs-Universität Freiburg (Open Access Publishing)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Physical Sciences › Computer Science › Computer Networks and Communications › RFID technology advancements
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- near field communication, wireless power transfer, interference suppression, low-power transceiver, energy efficiency, magnetic coupling, FPGA
- MeSH terms
- Communication, Energy Transfer, Equipment Design, Telemetry, Biosensing Techniques, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Very High Bit Rate Near-Field Communication with Low-Interference Coils and Digital Single-Bit Sampling Transceivers for Biomedical Sensor Systems. https://app.cochat.ai/papers/10.3390/s20216025
- The paper
- Stoecklin, S., Rosch, E., Yousaf, A., & Reindl, L. (2020). Very High Bit Rate Near-Field Communication with Low-Interference Coils and Digital Single-Bit Sampling Transceivers for Biomedical Sensor Systems. Sensors. https://doi.org/10.3390/s20216025
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.