Beyond the standard clinical rating scales: Fine-grained assessment of post-stroke motor functionality using wearable inertial sensors
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Accurate motor function assessment of post-stroke patients plays a critical role in their rehabilitation interventions. In this paper, we propose an approach to use wearable inertial sensing technology to quantitatively evaluate the patients' motor behavior. Different from existing wearable motor function assessment techniques that focus on building mapping functions that correlate sensed movement signals to the standard clinical rating scales, our approach provides a fine-grained assessment by capturing detailed patterns contained in the patients' movements. We collected data on three subjects including two post-stroke patients who have varying degrees of upper extremity hemiparesis. Our experimental results validate our approach and demonstrate that the captured patterns can be used to complement the standard clinical scores to provide fine-grained motor function assessment and help clinicians to track patients' gradual progress during rehabilitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monitoring Motor Fluctuations in Patients With Parkinson's Disease Using Wearable Sensors
Patel, S., Lorincz, K., Hughes, R., Huggins, N., Growdon, J., Standaert, D., Akay, M., Dy, J., Welsh, M., & Bonato, P. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033471 · Cited by 623 · cited 1×
“They demonstrated that patients with different severities can be represented by well separated clusters.”
BackgroundUsing Wearable Sensors to Measure Motor Abilities following Stroke
Hester, T., Hughes, R., Sherrill, D. M., Knorr, B., Akay, M., Stein, J., & Bonato, P. (2006) · International Workshop on Wearable and Implantable Body Sensor Networks (BSN'06) · doi:10.1109/bsn.2006.57 · Cited by 82 · cited 1×
“Alternatively, wearable inertial sensing technology uses accelerometers and gyroscopes to directly measure the movement’s acceleration and rotation.”
Background
Cited by
Maceira-Elvira, P., Popa, T., Schmid, A.-C., & Hummel, F. C. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0612-y · Cited by 265
Noorkõiv, M., Rodgers, H., & Price, C. I. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-144 · Cited by 141
Ploderer, B., Fong, J., Klaic, M., Nair, S., Vetere, F., Cofré Lizama, L. E., & Galea, M. P. (2016) · JMIR Rehabilitation and Assistive Technologies · doi:10.2196/rehab.6182 · Cited by 22
“This line of research is typically focused on technical challenges (ie, the accuracy of motion tracking [12,15]), reliability of tracking over long periods of time [16], wearability for patients [17], and the processing of metrics from sensor data [18].”
BackgroundButt, A. H., Zambrana, C., Idelsohn-Zielonka, S., Claramunt-Molet, M., Ugartemendia-Etxarri, A., Rovini, E., Moschetti, A., Molleja, C., Martin, C., Salleras, E. O., et al. (2019) · 2019 IEEE Conference on Computational Intelligence in Bioinformatics and Computational Biology (CIBCB) · doi:10.1109/cibcb.2019.8791470 · Cited by 6
Metadata
- Authors
- Zhang, M., Lange, B., Chang, C.-Y., Sawchuk, A. A., & Rizzo, A. A.
- Venue
- 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2012-08
- Volume
- 2012
- Pages
- 6111-6115
- OpenAlex
- W2091551897
- Cited by
- 36
- References
- 2
- FWCI
- 3.73
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.