EyeCatch: Data-mining over half a million EEG independent components to construct a fully-automated eye-component detector
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Independent component analysis (ICA) can find distinct sources of electroencephalographic (EEG) activity, both brain-based and artifactual, and has become a common pre-preprocessing step in analysis of EEG data. Distinction between brain and non-brain independent components (ICs) accounting for, e.g., eye or muscle activities is an important step in the analysis. Here we present a fully automated method to identify eye-movement related EEG components by analyzing the spatial distribution of their scalp projections (scalp maps). The EyeCatch method compares each input scalp map to a database of eye-related IC scalp maps obtained by data-mining over half a million IC scalp maps obtained from 80,006 EEG datasets associated with a diverse set of EEG studies and paradigms. To our knowledge this is the largest sample of IC scalp maps that has ever been analyzed. Our result show comparable performance to a previous state-of-art semi-automated method, CORRMAP, while eliminating the need for human intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967
Cited by
Chang, C.-Y., Hsu, S.-H., Pion-Tonachini, L., & Jung, T.-P. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2930186 · Cited by 544
Robust artifactual independent component classification for BCI practitioners
Winkler, I., Brandl, S., Horn, F., Waldburger, E., Allefeld, C., & Tangermann, M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035013 · Cited by 327
Moguilner, S., Baez, S., Hernandez, H., Migeot, J., Legaz, A., Gonzalez-Gomez, R., Farina, F. R., Prado, P., Cuadros, J., Tagliazucchi, E., et al. (2024) · Nature Medicine · doi:10.1038/s41591-024-03209-x · Cited by 128
“ICLabel (a tool for classifying EEG independent components into signals and different noise categories) 66 , and EyeCatch (a tool for identifying eye-related independent component analysis scalp maps) were used 67 .”
MethodDementia ConnEEGtome: towards multicentric harmonization of EEG connectivity in neurodegeneration
Prado, P., Birba, A., Cruzat, J., Santamaría-García, H., Parra, M., Moguilner, S., Tagliazucchi, E., & Ibáñez, A. (2022) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2021.12.008 · Cited by 43
“For that purpose, processing tools containing a database of manually identified eye-related ICA scalp maps have been developed (Bigdely-Shamlo et al., 2013).”
MethodStructural inequality and temporal brain dynamics across diverse samples
Baez, S., Hernandez, H., Moguilner, S., Cuadros, J., Santamaria‐Garcia, H., Medel, V., Migeot, J., Cruzat, J., Valdes‐Sosa, P. A., Lopera, F., et al. (2024) · Clinical and Translational Medicine · doi:10.1002/ctm2.70032 · Cited by 21
Metadata
- Authors
- Bigdely-Shamlo, N., Kreutz-Delgado, K., Kothe, C., & Makeig, S.
- Venue
- 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2013-07
- Volume
- 2013
- Pages
- 5845-5848
- OpenAlex
- W2021682187
- Cited by
- 78
- References
- 1
- FWCI
- 5.82
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.