The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
On the influence of high-pass filtering on ICA-based artifact reduction in EEG-ERP
Abstract
Standard artifact removal methods for electroencephalographic (EEG) signals are either based on Independent Component Analysis (ICA) or they regress out ocular activity measured at electrooculogram (EOG) channels. Successful ICA-based artifact reduction relies on suitable pre-processing. Here we systematically evaluate the effects of high-pass filtering at different frequencies. Offline analyses were based on event-related potential data from 21 participants performing a standard auditory oddball task and an automatic artifactual component classifier method (MARA). As a pre-processing step for ICA, high-pass filtering between 1-2 Hz consistently produced good results in terms of signal-to-noise ratio (SNR), single-trial classification accuracy and the percentage of `near-dipolar' ICA components. Relative to no artifact reduction, ICA-based artifact removal significantly improved SNR and classification accuracy. This was not the case for a regression-based approach to remove EOG artifacts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiple emitter location and signal parameter estimation
Schmidt, R. (1986) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.1986.1143830 · Cited by 14,718
Independent Component Analysis
(2004) · Independent Component Analysis · doi:10.7551/mitpress/3717.003.0014 · Cited by 7,903
A Fast Fixed-Point Algorithm for Independent Component Analysis
Hyvärinen, A., & Oja, E. (1997) · Neural Computation · doi:10.1162/neco.1997.9.7.1483 · Cited by 3,391
Independent Component Analysis: Principles and Practice
(2001) · Cambridge University Press eBooks · doi:10.1017/cbo9780511624148 · Cited by 1,917
Single-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138
Independent EEG Sources Are Dipolar
Delorme, A., Palmer, J., Onton, J., Oostenveld, R., & Makeig, S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030135 · Cited by 810
Automatic Classification of Artifactual ICA-Components for Artifact Removal in EEG Signals
Winkler, I., Haufe, S., & Tangermann, M. (2011) · Behavioral and Brain Functions · doi:10.1186/1744-9081-7-30 · Cited by 778
Self-citationRemoval of ocular artifact from the EEG: a review
Croft, R. J., & Barry, R. J. (2000) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/s0987-7053(00)00055-1 · Cited by 756
Digital filter design for electrophysiological data – a practical approach
Widmann, A., Schröger, E., & Maess, B. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.08.002 · Cited by 711
Scheeringa, R., Fries, P., Petersson, K.-M., Oostenveld, R., Grothe, I., Norris, D. G., Hagoort, P., & Bastiaansen, M. C. M. (2011) · Neuron · doi:10.1016/j.neuron.2010.11.044 · Cited by 446
Robust artifactual independent component classification for BCI practitioners
Winkler, I., Brandl, S., Horn, F., Waldburger, E., Allefeld, C., & Tangermann, M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035013 · Cited by 327
Self-citationIdentifying reliable independent components via split-half comparisons
Groppe, D. M., Makeig, S., & Kutas, M. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.038 · Cited by 207
3.1 Using ICA for the Analysis of Multi-Channel EEG Data
Debener, S., Thorne, J., Schneider, T. R., & Viola, F. C. (2010) · Simultaneous EEG and fMRI · doi:10.1093/acprof:oso/9780195372731.003.0008 · Cited by 169
Self-citationListen, You are Writing! Speeding up Online Spelling with a Dynamic Auditory BCI
Schreuder, M., Rost, T., & Tangermann, M. (2011) · Frontiers in Neuroscience · doi:10.3389/fnins.2011.00112 · Cited by 155
Self-citationFarquhar, J. D. R., & Hill, N. J. (2012) · Neuroinformatics · doi:10.1007/s12021-012-9171-0 · Cited by 104
Ocular Reduction in EEG Signals Based on Adaptive Filtering, Regression and Blind Source Separation
Romero, S., Mañanas, M. Á., & Barbanoj, M. J. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9589-6 · Cited by 87
Enhancing the signal-to-noise ratio of ICA-based extracted ERPs
Lemm, S., Curio, G., Hlushchuk, Y., & Müller, K. R. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.870258 · Cited by 78
Classification of independent components of EEG into multiple artifact classes
Frølich, L., Andersen, T., & Mørup, M. (2014) · Psychophysiology · doi:10.1111/psyp.12290 · Cited by 63
Effects of eye artifact removal methods on single trial P300 detection, a comparative study
Ghaderi, F., Kim, S. K., & Kirchner, E. A. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.08.025 · Cited by 46
Bougrain, L., Saavedra, C., & Ranta, R. (2012) · HAL · Cited by 35
Pignat, J., Koval, O., Ville, D. V. D., Voloshynovskiy, S., Michel, C. M., & Pun, T. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.10.011 · Cited by 28
Influence of Signal Preprocessing on ICA-Based EEG Decomposition
Zakeri, Z., Assecondi, S., Bagshaw, A. P., & Arvanitis, T. N. (2013) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-00846-2_182 · Cited by 27
Cited by
Gabard-Durnam, L. J., Mendez Leal, A. S., Wilkinson, C. L., & Levin, A. R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00097 · Cited by 535
Rogasch, N. C., Sullivan, C., Thomson, R. H., Rose, N. S., Bailey, N. W., Fitzgerald, P. B., Farzan, F., & Hernandez-Pavon, J. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.10.031 · Cited by 411
EEG-Based BCI Emotion Recognition: A Survey
Torres, E. P., Torres, E. A., Hernández-Álvarez, M., & Yoo, S. G. (2020) · Sensors · doi:10.3390/s20185083 · Cited by 291
Klug, M., & Gramann, K. (2021) · European Journal of Neuroscience · doi:10.1111/ejn.14992 · Cited by 268
Longitudinal EEG power in the first postnatal year differentiates autism outcomes
Gabard-Durnam, L. J., Wilkinson, C., Kapur, K., Tager-Flusberg, H., Levin, A. R., & Nelson, C. A. (2019) · Nature Communications · doi:10.1038/s41467-019-12202-9 · Cited by 179
Metadata
- Authors
- Winkler, I., Debener, S., Muller, K.-R., & Tangermann, M.
- Venue
- 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2015-08
- Volume
- 2015
- Pages
- 4101-4105
- OpenAlex
- W2296103515
- Cited by
- 407
- References
- 22
- FWCI
- 21.28
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.