CoChat

Evaluation of the beat-to-beat detection accuracy of PulseOn wearable optical heart rate monitor

Parak, Jakub, Tarniceriu, Adrian, Renevey, Philippe, Bertschi, Mattia, Delgado-Gonzalo, Ricard, Korhonen, Ilkka · 2015 · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Cited by 96

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Heart rate variability (HRV) provides significant information about the health status of an individual. Optical heart rate monitoring is a comfortable alternative to ECG based heart rate monitoring. However, most available optical heart rate monitoring devices do not supply beat-to-beat detection accuracy required by proper HRV analysis. We evaluate the beat-to-beat detection accuracy of a recent wrist-worn optical heart rate monitoring device, PulseOn (PO). Ten subjects (8 male and 2 female; 35.9±10.3 years old) participated in the study. HRV was recorded with PO and Firstbeat Bodyguard 2 (BG2) device, which was used as an ECG based reference. HRV was recorded during sleep. As compared to BG2, PO detected on average 99.57% of the heartbeats (0.43% of beats missed) and had 0.72% extra beat detection rate, with 5.94 ms mean absolute error (MAE) in beat-to-beat intervals (RRI) as compared to the ECG based RRI BG2. Mean RMSSD difference between PO and BG2 derived HRV was 3.1 ms. Therefore, PO provides an accurate method for long term HRV monitoring during sleep.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/embc.2015.7320273

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Heart rate variability: A review

    Rajendra Acharya, U., Paul Joseph, K., Kannathal, N., Lim, C. M., & Suri, J. S. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0119-0 · Cited by 2,820 · cited 1×

    “Accurate detection of beat-to-beat heart rate is necessary for the analysis of the HRV [4, 5]”
    Background
  • How accurate is pulse rate variability as an estimate of heart rate variability?

    Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661 · cited 1×

    “However, it has been suggested that pulse rate variability (PRV) from PPG is sufficiently accurate only for healthy (and mostly younger) subjects at rest, HRV estimated from PRV tends to be overestimated against ECG based values, and motion artifacts lead to inaccurate PPGbased beat detection [15].”
    Background

Show all 2 references

Cited by

See all 96

Metadata

Authors
Parak, J., Tarniceriu, A., Renevey, P., Bertschi, M., Delgado-Gonzalo, R., & Korhonen, I.
Venue
2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Publisher
IEEE
Published
2015-08
Volume
2015
Pages
8099-8102
OpenAlex
W2293491888
Cited by
96
References
2
FWCI
15.93
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of the beat-to-beat detection accuracy of PulseOn wearable optical heart rate monitor. https://app.cochat.ai/papers/10.1109/embc.2015.7320273
The paper
Parak, J., Tarniceriu, A., Renevey, P., Bertschi, M., Delgado-Gonzalo, R., & Korhonen, I. (2015). Evaluation of the beat-to-beat detection accuracy of PulseOn wearable optical heart rate monitor. 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). https://doi.org/10.1109/embc.2015.7320273

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.