Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 101 of the 101 references it cites were found in a registry or an index.

Digital biomarkers for Alzheimer’s disease: the mobile/wearable devices opportunity

Open access

Abstract

Alzheimer’s Disease (AD) represents a major and rapidly growing burden to the healthcare ecosystem. A growing body of evidence indicates that cognitive, behavioral, sensory, and motor changes may precede clinical manifestations of AD by several years. Existing tests designed to diagnose neurodegenerative diseases, while well-validated, are often less effective in detecting deviations from normal cognitive decline trajectory in the earliest stages of the disease. In the quest for gold standards for AD assessment, there is a growing interest in the identification of readily accessible digital biomarkers, which harness advances in consumer grade mobile and wearable technologies. Topics examined include a review of existing early clinical manifestations of AD and a path to the respective sensor and mobile/wearable device usage to acquire domain-centric data towards objective, high frequency and passive digital phenotyping.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41746-019-0084-2

Cites

101 of 101 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Consumer wearable and mobile devices offer a large personalized, direct, and high frequency sensing potential. Microphones can sense ambient noise and voice. Touch screens can probe for fine motor skills in swiping and typing. Cameras can register eye movements, gaze, and pupillary reflexes as well as capture facial expression traits. Altimeters offer useful information with respect to activity and barometers provide atmospheric pressure readings and weather data. PPG (Photoplethysmography) provides beat-to-beat heart rate measurements (HRM), heart rate variability (HRV) and oxygen saturation (SpO2). IMU (Inertia Measurement Unit) includes accelerometer, gyroscope and magnetometer (9 spatial values) and is used by numerous applications to track activity. Geopositioning sensors (GPS and WiFi localization) provide accurate location information. Light sensors read ambient visible or UV radiation levels. Thermometers on rings, patches or watches provide body temperature readings. Electromyograph sensors (EMG) found on patches or suits yield muscle group activity signals. Electrodermograph (EDG) or Galvanic Skin Response (GSR) sensors equip patches and watches to measure the skin conductance and potential or the skin resistance/impendance. Social interactions can be monitored using proximity to Bluetooth or Wi-Fi enabled devices as well as by monitoring overall phone use (calls, texts) and social network activity. Finally, wearable/mobile devices are equipped with logic components that can probe the executive function and memory of a user
Fig. 1 Consumer wearable and mobile devices offer a large personalized, direct, and high frequency sensing potential. Microphones can sense ambient noise and voice. Touch screens can probe for fine motor skills in swiping and typing. Cameras can register eye movements, gaze, and pupillary reflexes as well as capture facial expression traits. Altimeters offer useful information with respect to activity and barometers provide atmospheric pressure readings and weather data. PPG (Photoplethysmography) provides beat-to-beat heart rate measurements (HRM), heart rate variability (HRV) and oxygen saturation (SpO2). IMU (Inertia Measurement Unit) includes accelerometer, gyroscope and magnetometer (9 spatial values) and is used by numerous applications to track activity. Geopositioning sensors (GPS and WiFi localization) provide accurate location information. Light sensors read ambient visible or UV radiation levels. Thermometers on rings, patches or watches provide body temperature readings. Electromyograph sensors (EMG) found on patches or suits yield muscle group activity signals. Electrodermograph (EDG) or Galvanic Skin Response (GSR) sensors equip patches and watches to measure the skin conductance and potential or the skin resistance/impendance. Social interactions can be monitored using proximity to Bluetooth or Wi-Fi enabled devices as well as by monitoring overall phone use (calls, texts) and social network activity. Finally, wearable/mobile devices are equipped with logic components that can probe the executive function and memory of a userCC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 99 references

Research works printed but not linked: 1

  1. Vitiello, M. V. & Borson, S. Sleep disturbances in patients with Alzheimer’s disease. Mol. Diag Ther. 15, 777–796 (2001).

Cited by

See all 476

Metadata

Authors
Kourtis, L. C., Regele, O. B., Wright, J. M., & Jones, G. B.
Affiliations
  • Tufts University (US)
  • Eli Lilly (United States) (US)
Corresponding author
  • Kourtis, Lampros C.
  • Jones, Graham B.
Venue
npj Digital Medicine
Published
2019-02-21
Volume
2
Issue
1
ISSN
2398-6352 (ISSN-L)
OpenAlex
W2917347002
Cited by
476
References
99
Citations by year
2026: 75 · 2025: 105 · 2024: 71 · 2023: 60 · 2022: 60 · 2021: 57 · 2020: 35 · 2019: 12
FWCI
32.59
Type
journal article
Language
en
Open access
Licence
Locations
  • npj Digital Medicine (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
  • National Institutes of Health (UL1TR002544)
  • National Center for Advancing Translational Sciences (NIH UL1)
Topics
  • Health Sciences › Medicine › Psychiatry and Mental health › Dementia and Cognitive Impairment Research
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
Keywords
Alzheimer's disease, digital biomarkers, mobile devices, wearable sensors, digital phenotyping, early detection, cognitive decline, neurodegenerative diseases, passive sensing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Digital biomarkers for Alzheimer’s disease: the mobile/wearable devices opportunity. https://app.cochat.ai/papers/10.1038/s41746-019-0084-2
The paper
Kourtis, L. C., Regele, O. B., Wright, J. M., & Jones, G. B. (2019). Digital biomarkers for Alzheimer’s disease: the mobile/wearable devices opportunity. npj Digital Medicine. https://doi.org/10.1038/s41746-019-0084-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.