Regulatory authorities require that the safety and efficacy of a new high-risk medical device be proven in a Clinical Trial (CT), in which the effects of the device on a group of patients are compared to the effects of the current standard of care. Phase III trials can run for several years, cost millions of dollars, and expose patients to an unproven device. In this paper, we demonstrate how to use a large group of synthetic patients based on computer modeling to improve the planning of a CT so as to increase the chances of a successful trial for implantable cardioverter defibrillators (ICDs). We developed a computer model of the electrical generation and propagation in the heart. This model was used to generate a large group of heart instances capable of producing episodes of 19 different arrhythmias. We also implemented two arrhythmia detection algorithms from the literature: Rhythm ID from Boston Scientific and PR Logic + Wavelet from Medtronic. Using this setup, we conducted multiple in-silico trials to compare the ability of the two algorithms to appropriately discriminate between potentially fatal Ventricular Tachy-arrhythmias (VT) and nonfatal Supra-Ventricular Tachy-arrhythmias (SVTs). The results of our in-silico trial indicate that Rhythm ID was less able to discriminate between SVT and VT and so may lead to more cases of inappropriate therapy. This corroborates the findings of the Rhythm ID Going Head to Head Trial (RIGHT), a clinical trial that compared the two algorithms in patients. We further demonstrated that the result continues to hold if we vary the distribution of arrhythmias in the synthetic population. We also used the same in-silico cohort to explore the sensitivity of the outcome to different parameter settings of the device algorithms, which is not feasible in a real clinical trial. In-silico trials can provide early insight into the factors which affect the outcome of a CT at a fraction of the cost and duration and without the ethical issues.

Overview

Integrity signals

Registry

Crossref · 10.1109/embc.2016.7590667

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 10 references

Research works printed but not linked: 3

  1. abbas, 2016, Model-based Clinical Trials for Implantable Cardiac Defibrillators, Technical Report
  2. 2007, The Compass - Technical Guide to Boston Scientific Cardiac Rhythm Management Products, Development Documentation
  3. 0, Ask The ICD

Cited by

Metadata

Authors
Jiang, Z., Abbas, H., Jang, K. J., Beccani, M., Liang, J., Dixit, S., & Mangharam, R.
Affiliations
University of Pennsylvania (US)
Venue
2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Publisher
IEEE
Published
2016-08
Volume
2016
Pages
169-172
ISSN
2375-7477 (ISSN-L)
OpenAlex
W2537390084
Cited by
16
References
10
Citations by year
2026: 1 · 2025: 2 · 2024: 1 · 2023: 2 · 2022: 3 · 2021: 1 · 2019: 2 · 2018: 3 · 2017: 1
FWCI
5.62
Type
conference paper
Language
en
Open access
closed
Locations
  • Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
Keywords
implantable cardioverter-defibrillator, in silico clinical trials, arrhythmia detection algorithms, ventricular tachyarrhythmia, supraventricular tachyarrhythmias, clinical trial design
MeSH terms
Algorithms, Arrhythmias, Cardiac, Clinical Trials as Topic, Computer Simulation, Heart, Humans, Models, Cardiovascular, Tachycardia, Supraventricular, Defibrillators, Implantable, Tachycardia, Ventricular

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.