Robust Epileptic Seizure Detection on Wearable Systems with Reduced False-Alarm Rate
Open accessAbstract
Epilepsy affects more than 50 million people and ranks among the most common neurological diseases worldwide. Despite advances in treatment, one-third of patients still suffer from refractory epilepsy. Wearable devices for real-time patient monitoring can potentially improve the quality of life for such patients and reduce the mortality rate due to seizure-related accidents and sudden death in epilepsy. However, the majority of employed seizure detection techniques and devices suffer from unacceptable false-alarm rate. In this paper, we propose a robust seizure detection methodology for a wearable platform and validate it on the Physionet.org CHB-MIT Scalp EEG database. It reaches sensitivity of 0.966 and specificity of 0.925, and reducing the false-alarm rate by 34.7%. We also evaluate the battery lifetime of the wearable system including our proposed methodology and demonstrate the feasibility of using it in real time for up to 40.87 hours on a single battery charge.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A ML model deployed on ATMega2560 microcontroller achieved high accuracy of 93.58% for detection and recovery from FoG in Parkinson's patients, balancing power consumption and processing speed [101].
“Such contributions can be recognized in the detection and recovery from FoGnin Parkinson's patients, achieving high accuracy of 93.58% by a ML model deployed on ATMega2560 microcontroller that is able to balance between power consumption and processing speed [101].”
From A Comprehensive Survey on TinyML (2023) · cites this paper as [101]
In [101], the accuracy drop is estimated to be 1.3%.
“In [101], the accuracy drop is estimated to be 1.3%.”
From A Comprehensive Survey on TinyML (2023) · cites this paper as [101]
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538 · see citing works
Permutation Entropy: A Natural Complexity Measure for Time Series
Bandt, C., & Pompe, B. (2002) · Physical Review Letters · doi:10.1103/physrevlett.88.174102 · Cited by 4,899 · see citing works
Wang, Y., Li, J., & Stoica, P. (2005) · Synthesis lectures on signal processing · doi:10.1007/978-3-031-02525-9 · Cited by 2,887 · see citing works
Klem, G. H., Lüders, H. O., Jasper, H. H., & Elger, C. E. (1999) · PubMed · Cited by 2,361 · see citing works
Application of machine learning to epileptic seizure onset detection and treatment
Shoeb, A. H. (2009) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 855 · see citing works
Ocak, H. (2008) · Expert Systems with Applications · doi:10.1016/j.eswa.2007.12.065 · Cited by 749 · see citing works
A Survey on Machine Learning for Data Fusion
Meng, T., Jing, X., Yan, Z., & Pedrycz, W. (2020) · Information Fusion · doi:10.1016/j.inffus.2019.12.001 · Cited by 677 · see citing works
Application of entropies for automated diagnosis of epilepsy using EEG signals: A review
Acharya, U. R., Fujita, H., Sudarshan, V. K., Bhat, S., & Koh, J. E. W. (2015) · Knowledge-Based Systems · doi:10.1016/j.knosys.2015.08.004 · Cited by 496 · see citing works
Seizure prediction with spectral power of EEG using cost-sensitive support vector machines
Park, Y., Luo, L., Parhi, K. K., & Netoff, T. I. (2011) · Epilepsia · doi:10.1111/j.1528-1167.2011.03138.x · Cited by 398 · see citing works
Clinical utility of EEG in diagnosing and monitoring epilepsy in adults
Tatum, W. O., Rubboli, G., Kaplan, P. W., Mirsattari, S., Radhakrishnan, K., Gloss, D. S., Caboclo, L. O. S. F., Drislane, F. W., Koutroumanidis, M., Schomer, D. L., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.01.019 · Cited by 323 · see citing works
Regalia, G., Onorati, F., Lai, M., Caborni, C., & Picard, R. W. (2019) · Epilepsy Research · doi:10.1016/j.eplepsyres.2019.02.007 · Cited by 240 · see citing works
Automated seizure detection systems and their effectiveness for each type of seizure
Ulate-Campos, A., Coughlin, F., Gaínza-Lein, M., Fernández, I. S., Pearl, P. L., & Loddenkemper, T. (2016) · Seizure · doi:10.1016/j.seizure.2016.06.008 · Cited by 233 · see citing works
Jenssen, S., Gracely, E. J., & Sperling, M. R. (2006) · Epilepsia · doi:10.1111/j.1528-1167.2006.00622.x · Cited by 212 · see citing works
Wearable technology in epilepsy: The views of patients, caregivers, and healthcare professionals
Bruno, E., Simblett, S., Lang, A., Biondi, A., Odoi, C., Schulze-Bonhage, A., Wykes, T., & Richardson, M. P. (2018) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2018.05.044 · Cited by 191 · see citing works
Multimodal nocturnal seizure detection in a residential care setting
Arends, J. B. A. M., Thijs, R. D., Gutter, T., Ungureanu, C., Cluitmans, P. J. M., Dijk, J. V., van Andel, J. M., Tan, F. I. Y., de Weerd, A., Vledder, B., et al. (2018) · Neurology · doi:10.1212/wnl.0000000000006545 · Cited by 124 · see citing works
Novel techniques for automated seizure registration: Patients' wants and needs
Hoppe, C., Feldmann, M., Blachut, B., Surges, R., Elger, C. E., & Helmstaedter, C. (2015) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2015.08.006 · Cited by 116 · see citing works
Chen, X., Solomon, I. C., & Chon, K. H. (2005) · doi:10.1109/iembs.2005.1615393 · Cited by 109 · see citing works
e-Glass: A Wearable System for Real-Time Detection of Epileptic Seizures
Sopic, D., Aminifar, A., & Atienza, D. (2018) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2018.8351728 · Cited by 107 · see citing works
Self-citationA Self-Aware Epilepsy Monitoring System for Real-Time Epileptic Seizure Detection
Forooghifar, F., Aminifar, A., Cammoun, L., et al. (2019) · Mobile Networks and Applications · doi:10.1007/s11036-019-01322-7 · Cited by 48 · see citing works
Self-citationUltra-Low Power Design of Wearable Cardiac Monitoring Systems
Braojos, R., Mamaghanian, H., Dias, A., Ansaloni, G., Atienza, D., Rincón, F. J., & Srinivasan Murali, A. (2014) · ACM/IEEE Design Automation Conference (DAC) · doi:10.1145/2593069.2596691 · Cited by 32 · see citing works
Self-citationNoise-Resilient and Interpretable Epileptic Seizure Detection
Thomas, A., Aminifar, A., & Atienza, D. (2020) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas45731.2020.9180429 · Cited by 11 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
A Comprehensive Survey on TinyML
Abadade, Y., Temouden, A., Bamoumen, H., Benamar, N., Chtouki, Y., & Hafid, A. S. (2023) · IEEE Access · doi:10.1109/access.2023.3294111 · Cited by 366 · see citing works
“87 hours of monitoring using a single battery charge (approximately a whole day of work); in addition to reduced amount of false-alarms that [101] worked on to obtain.”
BackgroundTowards Long-term Non-invasive Monitoring for Epilepsy via Wearable EEG Devices
Ingolfsson, T. M., Cossettini, A., Wang, X., Tabanelli, E., Tagliavini, G., Ryvlin, P., Benini, L., & Benatti, S. (2021) · 2021 IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas49922.2021.9644949 · Cited by 35 · see citing works
- Authors
- Zanetti, R., Aminifar, A., & Atienza, D.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- Venue
- 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2020-07
- Volume
- 2020
- Pages
- 4248-4251
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W3037110129
- Cited by
- 45
- References
- 21
- Citations by year
- 2026: 5 · 2025: 6 · 2024: 12 · 2023: 7 · 2022: 8 · 2021: 7
- FWCI
- 7.16
- Type
- conference paper
- Language
- en
- Open access
- green
- embc.embs.org
- Licence
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- PubMed (publishedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Psychiatry and Mental health › Epilepsy research and treatment
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- seizure detection, wearable devices, false alarm reduction, scalp EEG, CHB-MIT Scalp EEG Database, drug-resistant epilepsy, real-time patient monitoring, battery life
- MeSH terms
- Wearable Electronic Devices, Electroencephalography, Epilepsy, Humans, Quality of Life, Seizures
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review