Cited by 21Non-Invasive Vital Sign MonitoringObstructive Sleep Apnea ResearchHemodynamic Monitoring and Therapy

Pulse Oximetry at the Wrist During Sleep: Performance, Challenges and Perspectives

Braun, Fabian, Theurillat, Patrick, Proenca, Martin, Lemkaddem, Alia, Ferrario, Damien, De Jaegere, Kurt, Horvath, Christian M., Roth, Corinne +3 more·2020·2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC)

Abstract

The state-of-the-art non-invasive measurement of peripheral oxygen saturation (SpO2) during sleep is mainly based on pulse oximetry at the fingertip. Although this approach is noninvasive, it can still be obtrusive and cumbersome to apply, in particular for ambulatory monitoring over several nights.We developed a wrist-worn reflectance pulse oximetry device which can be embedded in a watch, making it less obtrusive and easy to apply. This device was tested in an ongoing clinical study on 57 subjects (33 patients and 24 healthy volunteers) undergoing a full overnight polysomnography recording. The accuracy was evaluated against state-of-the-art fingertip SpO2 measurements.In the 54 subjects available for analysis we obtained an SpO2 accuracy (ARMS) of 3.4 % when automatically rejecting 17.7 % of signals due to low quality. When further excluding measurements suffering from insufficient contact of the watch with the skin an ARMS of 2.7 % was obtained while rejecting a total of 23.2 % measurements. These accuracies comply with the ISO standard and the FDA guidance for pulse oximeters.The present results are promising and pave the way for unobtrusive and continuous monitoring of SpO2 to screen for sleep disordered breathing. Nonetheless, contact pressure and venous blood have shown to adversely affect the SpO2 estimation and remain a challenge for wrist-based reflectance pulse oximetry.

Integrity signals

Registry

Crossref · 10.1109/embc44109.2020.9176081

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Changes in position, contact pressure, and venous blood flow can result in inaccuracies in SpO2 assessment using reflectance mode PPG.

    “changes in position, contact pressure, and venous blood flow can result in inaccuracies”

    From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [142]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Braun, F., Theurillat, P., Proenca, M., Lemkaddem, A., Ferrario, D., De Jaegere, K., Horvath, C. M., Roth, C., Brill, A.-K., Lemay, M., & Ott, S. R.
Affiliations
  • Swiss Center for Electronics and Microtechnology (Switzerland) (CH)
  • University of Bern (CH)
Venue
2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC)
Publisher
IEEE
Published
2020-07
Volume
2020
Pages
5115-5118
ISSN
2375-7477 (ISSN-L)
OpenAlex
W3081605224
Cited by
21
References
9
Citations by year
2025: 4 · 2024: 5 · 2023: 1 · 2022: 5 · 2021: 5 · 2020: 1
FWCI
5.44
Type
conference paper
Language
en
Open access
closed
Locations
  • Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
  • PubMed (publishedVersion)
  • BORIS (University Library Bern) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Physiology › Obstructive Sleep Apnea Research
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
reflectance pulse oximetry, peripheral oxygen saturation, sleep monitoring, polysomnography, sleep-disordered breathing screening, contact pressure, ambulatory monitoring
MeSH terms
Fingers, Humans, Oximetry, Oxygen, Wrist, Wrist Joint

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review