Pulse Oximetry at the Wrist During Sleep: Performance, Challenges and Perspectives
Abstract
The state-of-the-art non-invasive measurement of peripheral oxygen saturation (SpO2) during sleep is mainly based on pulse oximetry at the fingertip. Although this approach is noninvasive, it can still be obtrusive and cumbersome to apply, in particular for ambulatory monitoring over several nights.We developed a wrist-worn reflectance pulse oximetry device which can be embedded in a watch, making it less obtrusive and easy to apply. This device was tested in an ongoing clinical study on 57 subjects (33 patients and 24 healthy volunteers) undergoing a full overnight polysomnography recording. The accuracy was evaluated against state-of-the-art fingertip SpO2 measurements.In the 54 subjects available for analysis we obtained an SpO2 accuracy (ARMS) of 3.4 % when automatically rejecting 17.7 % of signals due to low quality. When further excluding measurements suffering from insufficient contact of the watch with the skin an ARMS of 2.7 % was obtained while rejecting a total of 23.2 % measurements. These accuracies comply with the ISO standard and the FDA guidance for pulse oximeters.The present results are promising and pave the way for unobtrusive and continuous monitoring of SpO2 to screen for sleep disordered breathing. Nonetheless, contact pressure and venous blood have shown to adversely affect the SpO2 estimation and remain a challenge for wrist-based reflectance pulse oximetry.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Changes in position, contact pressure, and venous blood flow can result in inaccuracies in SpO2 assessment using reflectance mode PPG.
“changes in position, contact pressure, and venous blood flow can result in inaccuracies”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [142]
Cites
The validity and practicality of sun-reactive skin types I through VI
Fitzpatrick, T. B. (1988) · Archives of Dermatology · doi:10.1001/archderm.1988.01670060015008 · Cited by 4,339 · see citing works
Kapur, V. K., Auckley, D. H., Chowdhuri, S., Kuhlmann, D. C., Mehra, R., Ramar, K., & Harrod, C. G. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6506 · Cited by 3,253 · see citing works
Heart rate variability, sleep and sleep disorders
Stein, P. K., & Pu, Y. (2011) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2011.02.005 · Cited by 528 · see citing works
Utility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A. T., Shaltis, P., McCombie, D. B., Asada, H. H., Warner, D. S., & Warner, M. A. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 365 · see citing works
Shelley, K. H., Tamai, D., Jablonka, D., Gesquiere, M., Stout, R. G., & Silverman, D. G. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000145063.01043.4b · Cited by 91 · see citing works
Moyle, J. (1994) · Cited by 65 · see citing works
Wrist:Located Optical Device for Atrial Fibrillation Screening: a Clinical Study on Twenty Patients
Lemay, M., Fallet, S., Renevey, P., Solà, J., Solà, J., Leupi, C., Pruvot, E. J., & Vésin, J.-M. (2016) · Computing in cardiology · doi:10.22489/cinc.2016.200-350 · Cited by 23 · see citing works
Self-citationClinical validation of LTMS-S: A wearable system for vital signs monitoring
Chételat, O., Ferrario, D., Proença, M., Porchet, J.-A., Falhi, A., Grossenbacher, O., Delgado-Gonzalo, R., Ricca, N., & Sartori, C. S. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319054 · Cited by 22 · see citing works
Self-citationPerformance Assessment of a Dedicated Reflectance Pulse Oximeter in a Neonatal Intensive Care Unit
Proença, M., Grossenbacher, O., Dasen, S., et al. (2018) · doi:10.1109/embc.2018.8512504 · Cited by 13 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250 · see citing works
Recent advances in wearable sensors and portable electronics for sleep monitoring
Kwon, S., Kim, H., & Yeo, W.-H. (2021) · iScience · doi:10.1016/j.isci.2021.102461 · Cited by 209 · see citing works
- Authors
- Braun, F., Theurillat, P., Proenca, M., Lemkaddem, A., Ferrario, D., De Jaegere, K., Horvath, C. M., Roth, C., Brill, A.-K., Lemay, M., & Ott, S. R.
- Affiliations
- Swiss Center for Electronics and Microtechnology (Switzerland) (CH)
- University of Bern (CH)
- Venue
- 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2020-07
- Volume
- 2020
- Pages
- 5115-5118
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W3081605224
- Cited by
- 21
- References
- 9
- Citations by year
- 2025: 4 · 2024: 5 · 2023: 1 · 2022: 5 · 2021: 5 · 2020: 1
- FWCI
- 5.44
- Type
- conference paper
- Language
- en
- Open access
- closed
- Licence
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- PubMed (publishedVersion)
- BORIS (University Library Bern) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Physiology › Obstructive Sleep Apnea Research
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- reflectance pulse oximetry, peripheral oxygen saturation, sleep monitoring, polysomnography, sleep-disordered breathing screening, contact pressure, ambulatory monitoring
- MeSH terms
- Fingers, Humans, Oximetry, Oxygen, Wrist, Wrist Joint
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review