Validation of the Empatica E4 wristband

McCarthy, Cameron, Pradhan, Nikhilesh, Redpath, Calum, Adler, Andy·2016·2016 IEEE EMBS International Student Conference (ISC)

Abstract

A preliminary study into the signal quality of the Empatica's E4 portable photoplethysmogram device as validation for further research on using the device to detect the heart arrhythmia atrial fibrillation. In order to pursue this research, it was necessary to verify the quality of the data produced by the E4 device against a device currently used by clinicians to detect atrial fibrillation. This was done by having healthy volunteers wear both the Empatica E4 and the clinician standard device while following standard clinician procedure for atrial fibrillation diagnosis. The device was compared qualitatively against General Electric's SEER Light Extend Recorder holter portable electrocardiogram. The analysis was done by non-experts at varying academic levels. The primary reviewer's results showed similar data quality between both devices 85% of the time and the holter performed better 5% of the time.

Integrity signals

Registry

Crossref · 10.1109/embsisc.2016.7508621

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • HRV time-domain metrics from the Empatica device have been validated against ECG in previous studies.

    “HRV time-domain metrics from the Empatica device have been validated against ECG in previous studies.58–60”
  • The Empatica E4 is a research-grade wearable device capable of recording accelerometry (ACC), electrodermal activity (EDA), photoplethysmography (PPG), and skin temperature (TEMP) signals.

    “The Empatica E4 (Empatica Inc, Boston, MA, USA) is a research-grade wearable device capable of recording accelerometry (ACC), electrodermal activity (EDA), photoplethysmography (PPG), and skin temperature (TEMP) signals24”

    From Data quality evaluation in wearable monitoring (2022) · cites this paper as [24]

  • A complete loss of contact results in a 0-line for the EDA signal; motion artifacts without contact loss result in abrupt level changes or high amplitude fluctuations; and PPG shows considerable deviation from expected signal patterns.

    “While a complete loss of contact results in a 0-line for the EDA signal, motion artifacts without contact loss result in abrupt level changes or high amplitude fluctuations, and PPG shows considerable deviation from expected signal patterns24,42.”

    From Data quality evaluation in wearable monitoring (2022) · cites this paper as [24]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
McCarthy, C., Pradhan, N., Redpath, C., & Adler, A.
Affiliations
  • Carleton University (CA)
  • Ottawa Heart Institute (CA)
Venue
2016 IEEE EMBS International Student Conference (ISC)
Publisher
IEEE
Published
2016-05
Pages
1-4
OpenAlex
W2465675980
Cited by
235
References
2
Citations by year
2026: 13 · 2025: 20 · 2024: 31 · 2023: 38 · 2022: 22 · 2021: 26 · 2020: 34 · 2019: 31 · 2018: 14 · 2017: 4 · 2016: 1 · 2014: 1
FWCI
33.35
Type
conference paper
Language
en
Open access
closed
Locations
IEEE EMBS International Student Conference (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
Empatica E4, photoplethysmography, atrial fibrillation detection, wearable devices, device validation, signal quality, Holter electrocardiogram

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review