Stressing the accuracy: Wrist‐worn wearable sensor validation over different conditions
Abstract
Wearable sensors are promising instruments for conducting both laboratory and ambulatory research in psychophysiology. However, scholars should be aware of their measurement error and the conditions in which accuracy is achieved. This study aimed to assess the accuracy of a wearable sensor designed for research purposes, the E4 wristband (Empatica, Milan, Italy), in measuring heart rate (HR), heart rate variability (HRV), and skin conductance (SC) over five laboratory conditions widely used in stress reactivity research (seated rest, paced breathing, orthostatic, Stroop, speech task) and two ecological conditions (slow walking, keyboard typing). Forty healthy participants concurrently wore the wristband and two gold standard measurement systems (i.e., electrocardiography and finger SC sensor). The wristband accuracy was determined by evaluating the signal quality and the correlations with and the Bland‐Altman plots against gold standard‐derived measurements. Moreover, exploratory analyses were performed to assess predictors of measurement error. Mean HR measures showed the best accuracy over all conditions. HRV measures showed satisfactory accuracy in seated rest, paced breathing, and recovery conditions but not in dynamic conditions, including speaking. Accuracy was diminished by wrist movements, cognitive and emotional stress, nonstationarity, and larger wrist circumferences. Wrist SC measures showed neither correlation nor visual resemblance with finger SC signal, suggesting that the two sites may reflect different phenomena. Future studies are needed to assess the responsivity of wrist SC to emotional and cognitive stress. Limitations and implications for laboratory and ambulatory research are discussed.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Greater wearable movement is associated with decreased photoplethysmography accuracy.
“which may be due to the fact that greater wearable movement is associated with decreased PPG accuracy as discussed below62.”
From Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research (2020) · cites this paper as [62]
Higher body mass index, which likely covaries with larger wrist circumference, has been shown to be associated with reduced heart rate accuracy, although these outcomes have not been found in all studies.
“Higher body mass index, which likely covaries with larger wrist circumference as described above, has been shown to be associated with reduced HR accuracy42,62, although again these outcomes have not been found in all studies44,46.”
From Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research (2020) · cites this paper as [62]
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965 · see citing works
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 29,639 · see citing works
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 23,433 · see citing works
Studies of interference in serial verbal reactions
Stroop, J. R. (1935) · Journal of Experimental Psychology · doi:10.1037/h0054651 · Cited by 18,622 · see citing works
Information Theory and an Extension of the Maximum Likelihood Principle
Akaike, H. (1998) · Springer series in statistics · doi:10.1007/978-1-4612-1694-0_15 · Cited by 18,384 · see citing works
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289 · see citing works
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · see citing works
Kirschbaum, C., Pirke, K.-M., & Hellhammer, D. H. (2008) · Neuropsychobiology · doi:10.1159/000119004 · Cited by 6,093 · see citing works
Looking at pictures: Affective, facial, visceral, and behavioral reactions
LANG, P. J., GREENWALD, M. K., BRADLEY, M. M., & HAMM, A. O. (1993) · Psychophysiology · doi:10.1111/j.1469-8986.1993.tb03352.x · Cited by 3,190 · see citing works
AIC model selection using Akaike weights
Wagenmakers, E.-J., & Farrell, S. (2004) · Psychonomic Bulletin & Review · doi:10.3758/bf03206482 · Cited by 2,684 · see citing works
Dawson, M., Schell, A., & Filion, D. L. (2007) · Cambridge University Press eBooks · doi:10.1017/cbo9780511546396.007 · Cited by 2,425 · see citing works
Laborde, S., Mosley, E., & Thayer, J. F. (2017) · Frontiers in Psychology · doi:10.3389/fpsyg.2017.00213 · Cited by 2,336 · see citing works
Publication Recommendations for Electrodermal Measurements
Fowles, D. C., Christie, M. J., Edelberg, R., Grings, W. W., Lykken, D. T., & Venables, P. H. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb03024.x · Cited by 1,700 · see citing works
A continuous measure of phasic electrodermal activity
Benedek, M., & Kaernbach, C. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.04.028 · Cited by 1,689 · see citing works
Publication recommendations for electrodermal measurements
Society for Psychophysiological Research Ad Hoc Committee on Electrodermal Measures (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2012.01384.x · Cited by 1,288 · see citing works
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206 · see citing works
How accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661 · see citing works
Shcherbina, A., Mattsson, C., Waggott, D., Salisbury, H., Christle, J., Hastie, T., Wheeler, M., & Ashley, E. (2017) · Journal of Personalized Medicine · doi:10.3390/jpm7020003 · Cited by 625 · see citing works
Wearable Sleep Technology in Clinical and Research Settings
DE ZAMBOTTI, M., CELLINI, N., GOLDSTONE, A., COLRAIN, I. M., & BAKER, F. C. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001947 · Cited by 564 · see citing works
Self-citationCharacteristics of Resonance in Heart Rate Variability Stimulated by Biofeedback
Vaschillo, E. G., Vaschillo, B., & Lehrer, P. M. (2006) · Applied Psychophysiology and Biofeedback · doi:10.1007/s10484-006-9009-3 · Cited by 431 · see citing works
Quintana, D. S., Alvares, G. A., & Heathers, J. A. J. (2016) · Translational Psychiatry · doi:10.1038/tp.2016.73 · Cited by 420 · see citing works
Emotional sweating across the body: Comparing 16 different skin conductance measurement locations
van Dooren, M., de Vries, G.-J., & Janssen, J. H. (2012) · Physiology & Behavior · doi:10.1016/j.physbeh.2012.01.020 · Cited by 413 · see citing works
An Approach to Artifact Identification: Application to Heart Period Data
Berntson, G. G., Quigley, K. S., Jang, J. F., & Boysen, S. T. (1990) · Psychophysiology · doi:10.1111/j.1469-8986.1990.tb01982.x · Cited by 392 · see citing works
Rahman, F., Pechnik, S., Gross, D., Sewell, L., & Goldstein, D. S. (2011) · Clinical Autonomic Research · doi:10.1007/s10286-010-0098-y · Cited by 337 · see citing works
Wilhelm, F. H., & Grossman, P. (2010) · Biological Psychology · doi:10.1016/j.biopsycho.2010.01.017 · Cited by 311 · see citing works
ARTiiFACT: a tool for heart rate artifact processing and heart rate variability analysis.
Kaufmann, T., Sütterlin, S., Schulz, S. M., & Vögele, C. (2011) · Behavior Research Methods · doi:10.3758/s13428-011-0107-7 · Cited by 284 · see citing works
Comparing Methods of Clinical Measurement: Reporting Standards for Bland and Altman Analysis
Mantha, S., Roizen, M. F., Fleisher, L. A., Thisted, R. A., & Foss, J. F. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200003000-00018 · Cited by 263 · see citing works
Autonomic, Neuroendocrine, and Immune Responses to Psychological Stress: The Reactivity Hypothesisa
Cacioppo, J. T., Berntson, G. G., Malarkey, W. B., Kiecolt‐Glaser, J. K., Sheridan, J. F., Poehlmann, K. M., Burleson, M. H., Ernst, J. M., Hawkley, L. C., & Glaser, R. (1998) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1998.tb09605.x · Cited by 247 · see citing works
Validation of the Empatica E4 wristband
McCarthy, C., Pradhan, N., Redpath, C., & Adler, A. (2016) · 2016 IEEE EMBS International Student Conference (ISC) · doi:10.1109/embsisc.2016.7508621 · Cited by 235 · see citing works
de Geus, E. J. C., Gianaros, P. J., Brindle, R. C., Jennings, J. R., & Berntson, G. G. (2019) · Psychophysiology · doi:10.1111/psyp.13287 · Cited by 219 · see citing works
pracma: Practical Numerical Math Functions
Borchers, H. W. (2011) · doi:10.32614/cran.package.pracma · Cited by 203 · see citing works
Clinical experimental stress studies: methods and assessment
Bali, A., & Jaggi, A. S. (2015) · Reviews in the Neurosciences · doi:10.1515/revneuro-2015-0004 · Cited by 175 · see citing works
A practical approach to Bland-Altman plots and variation coefficients for log transformed variables
Euser, A. M., Dekker, F. W., & le Cessie, S. (2008) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2007.11.003 · Cited by 171 · see citing works
Wearable technology for cardiology: An update and framework for the future
Pevnick, J. M., Birkeland, K. T., Zimmer, R. J., Elad, Y., & Kedan, I. (2017) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2017.08.003 · Cited by 157 · see citing works
Emotion Recognition Using Physiological Signals: Laboratory vs. Wearable Sensors
Ragot, M., Martin, N., Em, S., Pallamin, N., & Diverrez, J.-M. (2017) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-60639-2_2 · Cited by 139 · see citing works
Cardiovascular reactivity in real life settings: Measurement, mechanisms and meaning
Zanstra, Y. J., & Johnston, D. W. (2010) · Biological Psychology · doi:10.1016/j.biopsycho.2010.05.002 · Cited by 138 · see citing works
A comparison of wearable and stationary sensors for stress detection
Ollander, S., Godin, C., Campagne, A., & Charbonnier, S. (2016) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2016.7844917 · Cited by 136 · see citing works
Towards long term monitoring of electrodermal activity in daily life
Setz, C., Gravenhorst, F., Schumm, J., Bert Arnrich, A., & Tröster, G. (2011) · Personal and Ubiquitous Computing · doi:10.1007/s00779-011-0463-4 · Cited by 131 · see citing works
Naschitz, J. E., Bezobchuk, S., Priselac, R. M., Sundick, S., Dreyfuss, D., Khorshidi, I., Karidis, A., Manor, H., Nagar, M., Peck, E. R., et al. (2004) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-005-4300-z · Cited by 114 · see citing works
Lobelo, F., Kelli, H. M., Tejedor, S. C., Pratt, M., McConnell, M. V., Martin, S. S., & Welk, G. J. (2016) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2016.02.007 · Cited by 113 · see citing works
Charlot, K., Cornolo, J., Brugniaux, J. V., Richalet, J., & Pichon, A. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/12/005 · Cited by 88 · see citing works
Chrisinger, B. W., & King, A. C. (2018) · International Journal of Health Geographics · doi:10.1186/s12942-018-0140-1 · Cited by 78 · see citing works
The relationship of sweat gland count to electrodermal activity
Freedman, L. W., SCERBO, A. S., Dawson, M. E., Raine, A., McClure, W. O., & Venables, P. H. (1994) · Psychophysiology · doi:10.1111/j.1469-8986.1994.tb01040.x · Cited by 66 · see citing works
Chhapola, V., Kanwal, S. K., & Brar, R. (2014) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563214553438 · Cited by 66 · see citing works
Pietilä, J., Mehrang, S., Tolonen, J., Helander, E. E., Jimison, H. B., Misha Pavel, C., & Korhonen, I. (2017) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-5122-7_37 · Cited by 59 · see citing works
Grant, C. C., van Rensburg, D. C. J., Strydom, N., & Viljoen, M. (2011) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2011.00422.x · Cited by 44 · see citing works
White-coat effect in normotension and hypertension
Zakopoulos, N. A., Kotsis, V., Pitiriga, V. C., Toumanidis, S. T., Lekakis, J. P., Nanas, S., Vemmos, K. N., Stamatelopoulos, S., & Moulopoulos, S. D. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200210000-00004 · Cited by 32 · see citing works
The Multimodal Assessment of Adult Attachment Security: Developing the Biometric Attachment Test
Parra, F., Miljkovitch, R., Persiaux, G., Morales, M. R., & Scherer, S. J. (2017) · Journal of Medical Internet Research · doi:10.2196/jmir.6898 · Cited by 19 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research
Nelson, B. W., Low, C. A., Jacobson, N., Areán, P., Torous, J., & Allen, N. B. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0297-4 · Cited by 241 · see citing works
Milstein, N., & Gordon, I. (2020) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2020.00148 · Cited by 180 · see citing works
A Review of Wearable Multi-Wavelength Photoplethysmography
Ray, D., Collins, T., Woolley, S., & Ponnapalli, P. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3121476 · Cited by 155 · see citing works
Privacy-preserving Federated Deep Learning for Wearable IoT-based Biomedical Monitoring
Can, Y. S., & Ersoy, C. (2021) · ACM Transactions on Internet Technology · doi:10.1145/3428152 · Cited by 123 · see citing works
Zhang, Y., Weaver, R. G., Armstrong, B., Burkart, S., Zhang, S., & Beets, M. W. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2020.1767348 · Cited by 88 · see citing works
Bolinski, F., Etzelmüller, A., De Witte, N. A. J., van Beurden, C., Debard, G., Bonroy, B., Cuijpers, P., Riper, H., & Kleiboer, A. (2021) · Behaviour Research and Therapy · doi:10.1016/j.brat.2021.103877 · Cited by 23 · see citing works
A PPG Signal Dataset Collected in Semi-Naturalistic Settings Using Galaxy Watch
Park, S., Zheng, D., & Lee, U. (2025) · Scientific Data · doi:10.1038/s41597-025-05152-z · Cited by 12 · see citing works
- Authors
- Menghini, L., Gianfranchi, E., Cellini, N., Patron, E., Tagliabue, M., & Sarlo, M.
- Affiliations
- University of Padua (IT)
- Corresponding author
- Menghini, Luca
- ORCID
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 2019-07-23
- Volume
- 56
- Issue
- 11
- Pages
- e13441-e13441
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2963323264
- Semantic Scholar
- f1dd89b0b7d12e2161e726e52868bf5477e078c8
- Cited by
- 157
- References
- 48
- Citations by year
- 2026: 9 · 2025: 28 · 2024: 22 · 2023: 31 · 2022: 28 · 2021: 25 · 2020: 13 · 2019: 1
- FWCI
- 12.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Psychophysiology (publishedVersion)
- PubMed (publishedVersion)
- Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion)
- Iris (University of Trento) (submittedVersion)
- CINECA IRIS Institutional Research information system (University of Urbino) (submittedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Funders
- Università degli Studi di Padova
- U.S. Food and Drug Administration
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Emotion and Mood Recognition
- Keywords
- wearable sensors, measurement accuracy, heart rate, heart rate variability, skin conductance, stress reactivity, ambulatory measurement, wrist kinematics, cognitive stress, emotional stress, non-stationarity, sensor validation, gold standard comparison
- MeSH terms
- Wearable Electronic Devices, Adolescent, Adult, Electrocardiography, Female, Fingers, Galvanic Skin Response, Heart Rate, Humans, Male, Middle Aged, Motor Activity, Psychomotor Performance, Stress, Psychological, Wrist, Monitoring, Ambulatory, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review