CoChat

Hydrogen maser ensemble performance and characterization of frequency standards

Parker, T.E. · 2003 · Proceedings of the 1999 Joint Meeting of the European Frequency and Time Forum and the IEEE International Frequency Control Symposium (Cat. No.99CH36313)
Cited by 28

The DOI matches its Crossref record.

Abstract

The performance of a post-processed clock ensemble dominated by active, cavity-tuned, hydrogen masers has been evaluated. The ensemble has an average frequency drift of less than /spl plusmn/3/spl times/10/sup -15/ per year, and an Allan deviation less than 1/spl times/10/sup -15/ for /spl tau/ between 4 hours and 100 days. This ensemble has been used to help characterize the frequency stability of a number of commercially available, high performance frequency standards.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/freq.1999.840736

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 28

Metadata

Authors
Parker, T. E.
Venue
Proceedings of the 1999 Joint Meeting of the European Frequency and Time Forum and the IEEE International Frequency Control Symposium (Cat. No.99CH36313)
Publisher
IEEE
Published
2003-01-22
Volume
1
Pages
173-176
OpenAlex
W2155363583
Cited by
28
References
0
FWCI
18.22
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hydrogen maser ensemble performance and characterization of frequency standards. https://app.cochat.ai/papers/10.1109/freq.1999.840736
The paper
Parker, T. E. (2003). Hydrogen maser ensemble performance and characterization of frequency standards. Proceedings of the 1999 Joint Meeting of the European Frequency and Time Forum and the IEEE International Frequency Control Symposium (Cat. No.99CH36313). https://doi.org/10.1109/freq.1999.840736

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.