Operation of the NIST-F1 caesium fountain primary frequency standard with a maser ensemble, including the impact of frequency transfer noise
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
The operation of a caesium fountain primary frequency standard is greatly influenced by the characteristics of two other important facilities. The first is a stable frequency reference and the second is the frequency-transfer system. A stable frequency reference such as a hydrogen maser is a virtual necessity since essentially no fountain dead time can be tolerated without it. The frequency stability of this reference has a significant impact on the procedures for evaluating certain systematic biases in the fountain. State-of-the-art frequency transfer technology is also necessary if the fountain is intended to contribute to TAI or to be compared with other remotely located frequency standards without excessive degradation of stated uncertainties. We discuss the facilities available at the National Institute of Standards and Technology (NIST) and how they impact the operation of NIST-F1, the primary frequency standard at NIST.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Atomic clocks with the stability level of 10 -16 have been created [19][20][21].”
From Determination of the geopotential and orthometric height based on frequency shift equation (2011) · cites this paper as [21]
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Accuracy evaluation of NIST-F1
Jefferts, S. R., Shirley, J., Parker, T. E., Heavner, T. P., Meekhof, D. M., Nelson, C., Levi, F., Costanzo, G., Marchi, A. D., Drullinger, R., et al. (2002) · Metrologia · doi:10.1088/0026-1394/39/4/1 · Cited by 402
Self-citationNIST-F1: recent improvements and accuracy evaluations
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/012 · Cited by 355
Self-citationUncertainty evaluation of the atomic caesium fountain CSF1 of the PTB
Weyers, S., H bner, U., Schr der, R., Tamm, C., & Bauch, A. (2001) · Metrologia · doi:10.1088/0026-1394/38/4/7 · Cited by 160
Controlling the Cold Collision Shift in High Precision Atomic Interferometry
dos Santos, F. P., Marion, H., Bize, S., Sortais, Y. R. P., Clairon, A., & Salomon, C. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.233004 · Cited by 110 · cited 1×
“This minimizes the impact of any maser noise because the cycle time is in the range where the maser noise is predominantly white FM, and consequently it averages down approximately as the square root of the number of cycles [9].”
BackgroundAssessment of GPS carrier-phase stability for time-transfer applications
Larson, K. M., Levine, J., Nelson, L. M., & Parker, T. E. (2000) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.827441 · Cited by 77 · cited 2×
“Such observations indicate that transfer instabilities are generally flicker PM in nature out to as many as 100 days [3, 14, 15].”
BackgroundSelf-citationCollisional Frequency Shifts in133CsFountain Clocks
Leo, P. J., Julienne, P. S., Mies, F. H., & Williams, C. J. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.3743 · Cited by 64
First comparison of remote cesium fountains
Parker, T., Hetzel, P., Jefferts, S., Weyers, S., Nelson, L., Bauch, A., & Levine, J. (2002) · Proceedings of the 2001 IEEE International Frequncy Control Symposium and PDA Exhibition (Cat. No.01CH37218) · doi:10.1109/freq.2001.956161 · Cited by 37 · cited 2×
“Uncertainty in frequency transfer generally decreases in a manner inversely proportional to the length of the time interval of the comparison, which makes long comparisons desirable [3].”
BackgroundSelf-citationHydrogen maser ensemble performance and characterization of frequency standards
Parker, T. E. (2003) · Proceedings of the 1999 Joint Meeting of the European Frequency and Time Forum and the IEEE International Frequency Control Symposium (Cat. No.99CH36313) · doi:10.1109/freq.1999.840736 · Cited by 28
Self-citationEnvironmental factors and hydrogen maser frequency stability
Parker, T. E. (1999) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.764861 · Cited by 26
Self-citation
Research works printed but not linked: 5
- Parker T E Hetzel P Jefferts S R Weyers S Nelson L M Bauch A Levine J, 2001, Proc. 2001 IEEE Int. Frequency Control Symp., 63
- 10.1103/physrevlett86.3743 · doi:10.1103/physrevlett86.3743
- Howe D A Peppler T K, 2003, Proc. 2003 Joint Meeting of the IEEE Int. Frequency Control Symp. and the European Frequency and Time Forum, 233
- Douglas R J Boulanger J S, 1997, Proc. 11th European Frequency and Time Forum, 345
- Parker T E Zhang V S McKinley A Nelson L M Rohde J Matsakis D, 2002, Proc. 2002 Precise Time and Time Interval Meeting, 381
Cited by
NIST-F1: recent improvements and accuracy evaluations
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/012 · Cited by 355
Self-citationSingle-Atom Optical Clock with High Accuracy
Oskay, W. H., Diddams, S. A., Donley, E. A., Fortier, T. M., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Delaney, M. J., Kim, K., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.020801 · Cited by 297
Self-citationObservation of theS01→P03Clock Transition inAl+27
Rosenband, T., Schmidt, P., Hume, D., Itano, W., Fortier, T., Stalnaker, J., Kim, K., Diddams, S., Koelemeij, J., Bergquist, J., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.220801 · Cited by 231
Fortier, T. M., Ashby, N., Bergquist, J. C., Delaney, M. J., Diddams, S. A., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Kim, K., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.070801 · Cited by 226
Self-citationFirst accuracy evaluation of NIST-F2
Heavner, T. P., Donley, E. A., Levi, F., Costanzo, G., Parker, T. E., Shirley, J. H., Ashby, N., Barlow, S., & Jefferts, S. R. (2014) · Metrologia · doi:10.1088/0026-1394/51/3/174 · Cited by 205
Self-citation
Metadata
- Authors
- Parker, T. E., Jefferts, S. R., Heavner, T. P., & Donley, E. A.
- Affiliations
- National Institute of Standards and Technology (US)
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2005-09-13
- Volume
- 42
- Issue
- 5
- Pages
- 423-430
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2132128253
- Cited by
- 220
- References
- 16
- Citations by year
- 2023: 3 · 2022: 7 · 2021: 13 · 2020: 12 · 2019: 14 · 2018: 12 · 2017: 13 · 2016: 13 · 2015: 11 · 2014: 15 · 2013: 14 · 2012: 11
- FWCI
- 9.42
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Metrologia (publishedVersion)
- Funders
- National Institute of Standards and Technology
- U.S. Naval Observatory
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- primary frequency standard, hydrogen maser, frequency stability, systematic bias, time and frequency transfer, TAI, uncertainty analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Operation of the NIST-F1 caesium fountain primary frequency standard with a maser ensemble, including the impact of frequency transfer noise. https://app.cochat.ai/papers/10.1088/0026-1394/42/5/013
- The paper
- Parker, T. E., Jefferts, S. R., Heavner, T. P., & Donley, E. A. (2005). Operation of the NIST-F1 caesium fountain primary frequency standard with a maser ensemble, including the impact of frequency transfer noise. Metrologia. https://doi.org/10.1088/0026-1394/42/5/013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.