CoChat

Heart rate monitoring from wrist-type photoplethysmographic (PPG) signals during intensive physical exercise

Zhang, Zhilin · 2014 · 2014 IEEE Global Conference on Signal and Information Processing (GlobalSIP)
Cited by 50

The DOI matches its Crossref record.

Abstract

Heart rate monitoring from wrist-type photoplethysmographic (PPG) signals during subjects' intensive exercise is a difficult problem, since the PPG signals are contaminated by extremely strong motion artifacts caused by subjects' hand movements. In this work, we formulate the heart rate estimation problem as a sparse signal recovery problem, and use a sparse signal recovery algorithm to calculate high-resolution power spectra of PPG signals, from which heart rates are estimated by selecting corresponding spectrum peaks. To facilitate the use of sparse signal recovery, we propose using bandpass filtering, singular spectrum analysis, and temporal difference operation to partially remove motion artifacts and sparsify PPG spectra. The proposed method was tested on PPG recordings from 10 subjects who were fast running at the peak speed of 15km/hour. The results showed that the averaged absolute estimation error was only 2.56 Beats/Minute, or 1.94% error compared to ground-truth heart rates from simultaneously recorded ECG.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/globalsip.2014.7032208

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 50

Metadata

Authors
Zhang, Z.
Venue
2014 IEEE Global Conference on Signal and Information Processing (GlobalSIP)
Publisher
IEEE
Published
2014-12
Pages
698-702
ISSN
2376-4066 (ISSN-L)
OpenAlex
W2064502866
Cited by
50
References
0
FWCI
12.21
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heart rate monitoring from wrist-type photoplethysmographic (PPG) signals during intensive physical exercise. https://app.cochat.ai/papers/10.1109/globalsip.2014.7032208
The paper
Zhang, Z. (2014). Heart rate monitoring from wrist-type photoplethysmographic (PPG) signals during intensive physical exercise. 2014 IEEE Global Conference on Signal and Information Processing (GlobalSIP). https://doi.org/10.1109/globalsip.2014.7032208

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.