Heart rate monitoring from wrist-type photoplethysmographic (PPG) signals during intensive physical exercise
The DOI matches its Crossref record.
Abstract
Heart rate monitoring from wrist-type photoplethysmographic (PPG) signals during subjects' intensive exercise is a difficult problem, since the PPG signals are contaminated by extremely strong motion artifacts caused by subjects' hand movements. In this work, we formulate the heart rate estimation problem as a sparse signal recovery problem, and use a sparse signal recovery algorithm to calculate high-resolution power spectra of PPG signals, from which heart rates are estimated by selecting corresponding spectrum peaks. To facilitate the use of sparse signal recovery, we propose using bandpass filtering, singular spectrum analysis, and temporal difference operation to partially remove motion artifacts and sparsify PPG spectra. The proposed method was tested on PPG recordings from 10 subjects who were fast running at the peak speed of 15km/hour. The results showed that the averaged absolute estimation error was only 2.56 Beats/Minute, or 1.94% error compared to ground-truth heart rates from simultaneously recorded ECG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zhang, Z., Pi, Z., & Liu, B. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2359372 · Cited by 748
Self-citationZhang, Z. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2406332 · Cited by 388
“2406332 In [4] and [5], several typical difficulties in HR estimation are”
BackgroundSelf-citationAccurate Heart Rate Monitoring During Physical Exercises Using PPG
Temko, A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2676243 · Cited by 293
Wristband-type wearable health devices to measure construction workers' physical demands
Hwang, S., & Lee, S. (2017) · Automation in Construction · doi:10.1016/j.autcon.2017.06.003 · Cited by 168
Organic Multi-Channel Optoelectronic Sensors for Wearable Health Monitoring
Khan, Y., Han, D., Ting, J., Ahmed, M., Nagisetty, R., & Arias, A. C. (2019) · IEEE Access · doi:10.1109/access.2019.2939798 · Cited by 111
“Another approach is to simultaneously record PPG and a reference signal such as an accelerometer signal and apply hybrid algorithms to determine heart rate (HR) and pulse oxygenation [25], [26].”
MethodHeart rate tracking in photoplethysmography signals affected by motion artifacts: a review
Ismail, S., Akram, U., & Siddiqi, I. (2021) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/s13634-020-00714-2 · Cited by 101
“In [64, 65], the authors utilized only the single ACC signal for reconstruction.”
BackgroundMethodInfluentialDesign, development and clinical validation of a wrist-based optical heart rate monitor
Preejith, S. P., Alex, A., Joseph, J., & Sivaprakasam, M. (2016) · 2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2016.7533786 · Cited by 41
“Adaptive filtering techniques using accelerometer data for retrieving back motion corrupted signals can be done for measurements taken during vigorous physical activity [13].”
Background
Metadata
- Authors
- Zhang, Z.
- Venue
- 2014 IEEE Global Conference on Signal and Information Processing (GlobalSIP)
- Publisher
- IEEE
- Published
- 2014-12
- Pages
- 698-702
- ISSN
- 2376-4066 (ISSN-L)
- OpenAlex
- W2064502866
- Cited by
- 50
- References
- 0
- FWCI
- 12.21
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.