Design, development and clinical validation of a wrist-based optical heart rate monitor
Abstract
Development in the field of sensor technology, hardware miniaturization, ubiquitous computing and connected solutions paved the way for the development of wearables for continuous physiological parameter monitoring. Continuous heart rate monitoring with clinical accuracy using reflectance photoplethysmogram signals from wrist is highly challenging and presents a potential area of research. In this work, we present a wearable device in a wrist watch form factor for heart rate monitoring. The device runs on a low power ARM cortex M4 microcontroller and integrates a BLE (Bluetooth Low energy) module for wireless connectivity. A heart rate computation algorithm using reflectance photoplethysmography and a 3 axes accelerometer for motion artifact removal is presented in the paper. Heart rate computed by the wrist worn device was validated against heart rate measured using Masimo Radical-7 on 256 subjects. The validation study was conducted in a hospital setting for a duration of 1 month, after obtaining the ethics committee approval and informed consent from the subjects. Details of the experimental setup, clinical validation protocol and observations and inferences made from the study are presented.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Preejith et al.'s device had an error of 1.04 BPM for 'fair' skinned individuals and 10.90 BPM for 'dark' skinned participants, a greater than 10 times increase in absolute error.
“There was an error of 1.04 beats per minute (BPM) for “fair” skinned individuals and an error of 10.90 BPM for “dark” skinned participants, citing the lack of usability of their device for dark skinned individuals.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [40]
Preejith et al. found a significant direct correlation between SNR of heart rate and skin tone using a 535 nm LED, indicating that a darker skin tone yields higher error in the measurement.
“Preejith et al. confirmed that skin tone matters when using green light only. The analysis of their PPG biosensor (single source 535 nm LED) showed a significant direct correlation SNR of the heart rate with skin tone, indicating that a darker skin tone yields higher error in the measurement [40].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [40]
Cites
Garbarino, M., Lai, M., Tognetti, S., Picard, R. W., & Bender, D. (2014) · Wireless Mobile Communication and Healthcare · doi:10.4108/icst.mobihealth.2014.257418 · Cited by 215 · see citing works
A Real-Time Human Stress Monitoring System Using Dynamic Bayesian Network
Liao, W., Zhang, W., Zhu, Z., & Ji, Q. (2006) · 2009 IEEE Computer Society Conference on Computer Vision and Pattern Recognition Workshops · doi:10.1109/cvpr.2005.394 · Cited by 171 · see citing works
Comparison of HRV parameters derived from photoplethysmography and electrocardiography signals
Jeyhani, V., Mahdiani, S., Peltokangas, M., & Vehkaoja, A. T. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319747 · Cited by 136 · see citing works
BioWatch: Estimation of Heart and Breathing Rates from Wrist Motions
Hernandez, J., McDuff, D., & Picard, R. W. (2015) · EAI Endorsed Transactions on Pervasive Health and Technology · doi:10.4108/icst.pervasivehealth.2015.259064 · Cited by 116 · see citing works
A new method for heart rate monitoring during physical exercise using photoplethysmographic signals
Schäck, T., Sledz, C., Muma, M., & Zoubir, A. M. (2015) · European Signal Processing Conference (EUSIPCO) · doi:10.1109/eusipco.2015.7362868 · Cited by 58 · see citing works
Evaluation of accuracy and reliability of PulseOn optical heart rate monitoring device
Delgado-Gonzalo, R., Parák, J., Tarniceriu, A., Renevey, P., Bertschi, M., & Korhonen, I. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318391 · Cited by 55 · see citing works
Thomas, S. S., Nathan, V., Zong, C., Akinbola, E., Aroul, A. L. P., Philipose, L., Soundarapandian, K., Shi, X., & Jafari, R. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944076 · Cited by 52 · see citing works
Zhang, Z. (2014) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip.2014.7032208 · Cited by 50 · see citing works
Tautan, A.-M., Young, A., Wentink, E., & Wieringa, F. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319795 · Cited by 47 · see citing works
Heart Rate Detection During Sleep Using a Flexible RF Resonator and Injection-Locked PLL Sensor
Kim, S. W., Choi, S. B., An, Y., et al. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2439681 · Cited by 41 · see citing works
Zong, C., & Jafari, R. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7320268 · Cited by 39 · see citing works
A low-power, wireless, wrist-worn device for long time heart rate monitoring and fall detection
Zhou, C., Tu, C., Gao, Y., et al. (2014) · International Conference on Orange Technologies · doi:10.1109/icot.2014.6954670 · Cited by 26 · see citing works
Efficient tracking of heart rate under physical exercise from photoplethysmographic signals
Frigo, G., Fabris, M., Galli, A., Gambarin, F. I., Marsili, I. A., Narduzzi, C., & Giorgi, G. B. D. (2015) · IEEE International Forum on Research and Technology for Society and Industry (RTSI) · doi:10.1109/rtsi.2015.7325116 · Cited by 8 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Shcherbina, A., Mattsson, C., Waggott, D., Salisbury, H., Christle, J., Hastie, T., Wheeler, M., & Ashley, E. (2017) · Journal of Personalized Medicine · doi:10.3390/jpm7020003 · Cited by 625 · see citing works
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
A Review of Wearable Multi-Wavelength Photoplethysmography
Ray, D., Collins, T., Woolley, S., & Ponnapalli, P. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3121476 · Cited by 155 · see citing works
Chow, H.-W., & Yang, C.-C. (2020) · JMIR mHealth and uHealth · doi:10.2196/14707 · Cited by 140 · see citing works
“In another validation study, the measured heart rate showed a minor deviation compared with the actual heart rate in participants with a dark skin tone [30].”
- Authors
- Preejith, S. P., Alex, A., Joseph, J., & Sivaprakasam, M.
- Affiliations
- Indian Institute of Technology Madras (IN)
- Venue
- 2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA)
- Publisher
- IEEE
- Published
- 2016-05
- Pages
- 1-6
- OpenAlex
- W2511765933
- Cited by
- 41
- References
- 13
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 3 · 2023: 8 · 2022: 11 · 2021: 3 · 2020: 3 · 2019: 3 · 2018: 1 · 2017: 4
- FWCI
- 5.34
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE International Symposium on Medical Measurements and Applications (MeMeA) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- wearable sensors, motion artifact removal, accelerometer, Bluetooth Low Energy, ARM Cortex-M4, clinical validation, continuous physiological monitoring, low-power embedded systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review