The hRing: A wearable haptic device to avoid occlusions in hand tracking
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The wearable electronics business has powered over $14 billion in 2014 and it is estimated to power over $70 billion by 2024. However, commercially-available wearable devices still provide very limited haptic feedback, mainly focusing on vibrotactile sensations. Towards a more realistic feeling of interacting with virtual and remote objects, we propose a novel wearable cutaneous device for the proximal finger phalanx, called "hRing". It consists of two servo motors that move a belt placed in contact with the user's finger skin. When the motors spin in opposite directions, the belt presses into the user's finger, while when the motors spin in the same direction, the belt applies a shear force to the skin. Its positioning on the proximal finger phalanx improves the capability of this device to be used together with unobtrusive hand tracking systems, such as the LeapMotion controller and the Kinect sensor. The viability of the proposed approach is demonstrated through a pick-and-place experiment involving seven human subjects. Providing cutaneous feedback through the proposed device improved the performance and perceived effectiveness of the considered task of 20% and 47% with respect to not providing any force feedback, respectively. All subjects found no difference in the quality of the tracking when carrying out the task wearing the device versus barehanded.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Johansson, R. S., & Vallbo, A. B. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012619 · Cited by 1,291
Analysis of the Accuracy and Robustness of the Leap Motion Controller
Weichert, F., Bachmann, D., Rudak, B., & Fisseler, D. (2013) · Sensors · doi:10.3390/s130506380 · Cited by 913
Cited by
Wearable Haptic Systems for the Fingertip and the Hand: Taxonomy, Review, and Perspectives
Pacchierotti, C., Sinclair, S., Solazzi, M., Frisoli, A., Hayward, V., & Prattichizzo, D. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2689006 · Cited by 825
Self-citationDeep Learning in Human Activity Recognition with Wearable Sensors: A Review on Advances
Zhang, S., Li, Y., Zhang, S., Shahabi, F., Xia, S., Deng, Y., & Alshurafa, N. (2022) · Sensors · doi:10.3390/s22041476 · Cited by 625
“1b, there are a large number of off-the-shelf smart devices or prototypes under development today, including smartphones, smartwatches, smart glasses, smart rings [208], smart gloves [266], smart armbands [151], smart necklaces [64, 142, 328], smart shoes [106], and Etattoos [249].”
BackgroundGrabity: A Wearable Haptic Interface for Simulating Weight and Grasping in Virtual Reality
Choi, I., Culbertson, H., Miller, M. R., Olwal, A., & Follmer, S. (2017) · Proceedings of the 30th Annual ACM Symposium on User Interface Software and Technology · doi:10.1145/3126594.3126599 · Cited by 266
Whitmire, E., Benko, H., Holz, C., Ofek, E., & Sinclair, M. (2018) · Proceedings of the 2018 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3173574.3173660 · Cited by 264
Haptic display for virtual reality: progress and challenges
WANG, D., GUO, Y., LIU, S., ZHANG, Y., XU, W., & XIAO, J. (2019) · Virtual Reality & Intelligent Hardware · doi:10.3724/sp.j.2096-5796.2019.0008 · Cited by 262
Metadata
- Authors
- Pacchierotti, C., Salvietti, G., Hussain, I., Meli, L., & Prattichizzo, D.
- Venue
- 2016 IEEE Haptics Symposium (HAPTICS)
- Publisher
- IEEE
- Published
- 2016-04
- Pages
- 134-139
- ISSN
- 2324-7347 (ISSN-L)
- OpenAlex
- W2345854622
- Cited by
- 123
- References
- 2
- FWCI
- 28.15
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The hRing: A wearable haptic device to avoid occlusions in hand tracking. https://app.cochat.ai/papers/10.1109/haptics.2016.7463167
- The paper
- Pacchierotti, C., Salvietti, G., Hussain, I., Meli, L., & Prattichizzo, D. (2016). The hRing: A wearable haptic device to avoid occlusions in hand tracking. 2016 IEEE Haptics Symposium (HAPTICS). https://doi.org/10.1109/haptics.2016.7463167
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.