Dynamic performance and control of a static VAr generator using cascade multilevel inverters
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
A cascade multilevel inverter is proposed for static VAr compensation/generation applications. The new cascade M-level inverter consists of (M-1)/2 single-phase full bridges in which each bridge has its own separate DC source. This inverter can generate an almost sinusoidal waveform voltage with only one time switching per cycle. It can eliminate the need for transformers in multipulse inverters. A prototype static VAr generator (SVG) system using an 11-level cascade inverter (21-level line-to-line voltage waveform) has been built. The output voltage waveform is equivalent to that of a 60-pulse inverter. This paper focuses on the dynamic performance of the cascade inverter based SVG system. Control schemes are proposed to achieve a fast response which is impossible for a conventional static VAr compensator (SVC). Analytical, simulation and experimental results show the superiority of the proposed SVG system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A multilevel voltage-source inverter with separate DC sources for static VAr generation
Peng, F. Z., Lai, J.-S., McKeever, J. W., & VanCoevering, J. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.536875 · Cited by 858
Self-citationA multilevel voltage-source inverter with separate DC sources for static VAr generation
Peng, F. Z., Lai, J.-S., McKeever, J., & VanCoevering, J. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530626 · Cited by 847
Self-citationComparison of multilevel inverters for static VAr compensation
Hochgraf, C., Lasseter, R., Divan, D., & Lipo, T. A. (2002) · Proceedings of 1994 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1994.377528 · Cited by 354
Mori, S., Matsuno, K., Hasegawa, T., Ohnishi, S., Takeda, M., Seto, M., Murakami, S., & Ishiguro, F. (1993) · IEEE Transactions on Power Systems · doi:10.1109/59.221218 · Cited by 319
Cited by
Multilevel converters for large electric drives
Tolbert, L. M., Peng, F. Z., & Habetler, T. G. (1999) · IEEE Transactions on Industry Applications · doi:10.1109/28.740843 · Cited by 1,408
Self-citationActive power filters: A review
El-Habrouk, M., Darwish, M. K., & Mehta, P. (2000) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20000522 · Cited by 657
Control and Performance of a Transformerless Cascade PWM STATCOM With Star Configuration
Akagi, H., Inoue, S., & Yoshii, T. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900487 · Cited by 643
Multilevel Converters: Fundamental Circuits and Systems
Akagi, H. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2682105 · Cited by 513
A new cascaded multilevel H-bridge drive
Corzine, K., & Familiant, Y. (2002) · IEEE Transactions on Power Electronics · doi:10.1109/63.988678 · Cited by 392
Metadata
- Authors
- Peng, F. Z., & Lai, J.-S.
- Venue
- IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting
- Publisher
- IEEE
- Published
- 2002-12-23
- Volume
- 2
- Pages
- 1009-1015
- ISSN
- 0197-2618 (ISSN-L)
- OpenAlex
- W2009458741
- Cited by
- 233
- References
- 4
- FWCI
- 18.87
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.