Fault detection and isolation on a PWM inverter by knowledge-based model
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
This paper presents an approach based on knowledge models to detect and localize faults in a PWM inverter supplying a synchronous machine. These faults don't affect the system protection. A diagnostic system which uses only the input variables of the drive is presented. It is based on the analysis of the current vector trajectory and of the instantaneous frequency in faulty mode. These two methods have been successfully applied to an experimental system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fault diagnosis in dynamic systems using analytical and knowledge-based redundancy
Frank, P. M. (1990) · Automatica · doi:10.1016/0005-1098(90)90018-d · Cited by 3,545
Fault Tree Analysis, Methods, and Applications ߝ A Review
Lee, W. S., Grosh, D. L., Tillman, F. A., & Lie, C. H. (1985) · IEEE Transactions on Reliability · doi:10.1109/tr.1985.5222114 · Cited by 678
Fault diagnosis of machines via parameter estimation and knowledge processing—Tutorial paper
Isermann, R. (1993) · Automatica · doi:10.1016/0005-1098(93)90088-b · Cited by 672
Investigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.297920 · Cited by 386
Investigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (2003) · Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1992.244307 · Cited by 370
FAULT DIAGNOSIS OF MACHINES VIA PARAMETER ESTIMATION AND KNOWLEDGE PROCESSING
Isermann, R. (1992) · Elsevier eBooks · doi:10.1016/b978-0-08-041275-7.50010-7 · Cited by 169
Cited by
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Survey on Reliability of Power Electronic Systems
Song, Y., & Wang, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192503 · Cited by 861
Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724
Fault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441
Overcurrent Protection on Voltage-Source-Converter-Based Multiterminal DC Distribution Systems
Baran, M. E., & Mahajan, N. R. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2006.877086 · Cited by 380
Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377
“PTDC/EEA-ELC/105282/2008.”
Fault Detection for Modular Multilevel Converters Based on Sliding Mode Observer
Shao, S., Wheeler, P. W., Clare, J. C., & Watson, A. J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2242093 · Cited by 361
Zidani, F., Diallo, D., Benbouzid, M. E. H., & Nait-Said, R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911951 · Cited by 335
Open-Transistor Fault Diagnostics in Voltage-Source Inverters by Analyzing the Load Currents
Sleszynski, W., Nieznanski, J., & Cichowski, A. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2023640 · Cited by 300
Fault-Tolerant Voltage-Fed PWM Inverter AC Motor Drive Systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825284 · Cited by 299
A New Approach for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Source Inverters
Estima, J. O., & Marques Cardoso, A. J. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168800 · Cited by 298
Fault-Tolerant Voltage Source Inverter for Permanent Magnet Drives
Errabelli, R. R., & Mutschler, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2135866 · Cited by 278
“[15] suggested the open switch fault detection by analyzing the current vector trajectory and of the instantaneous frequency in the faulty mode.”
BackgroundMethodOpen-Circuit Fault Diagnosis in PMSG Drives for Wind Turbine Applications
Freire, N. M. A., Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2207655 · Cited by 277
Jung, S.-M., Park, J.-S., Kim, H.-W., Cho, K.-Y., & Youn, M.-J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212916 · Cited by 271
Fuchs, F. W. (2004) · IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468) · doi:10.1109/iecon.2003.1280259 · Cited by 270
An, Q.-T., Sun, L.-Z., Zhao, K., & Sun, L. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2052472 · Cited by 262
Model-Based Fault Detection and Identification for Switching Power Converters
Poon, J., Jain, P., Konstantakopoulos, I. C., Spanos, C., Panda, S. K., & Sanders, S. R. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2541342 · Cited by 257
Fault-tolerant control in variable speed drives: a survey
Campos-Delgado, D. U., Espinoza-Trejo, D. R., & Palacios, E. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070203 · Cited by 228
Campos-Delgado, D. U., & Espinoza-Trejo, D. R. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2047829 · Cited by 224
“Meanwhile, in [20], two methods are proposed in order to detect and isolate the open-switch and offset current sensor faults.”
MethodPWM-VSI Fault Diagnosis for a PMSM Drive Based on the Fuzzy Logic Approach
Yan, H., Xu, Y., Cai, F., Zhang, H., Zhao, W., & Gerada, C. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2814615 · Cited by 216
“In [14], an approach based on knowledge models to detect and isolate faults in a PWM-VSI is proposed, which is implemented by analyzing the current-vector trajectory and the instantaneous frequency in the faulty mode.”
MethodJlassi, I., Estima, J. O., Khojet El Khil, S., Mrabet Bellaaj, N., & Marques Cardoso, A. J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2342506 · Cited by 212
“The current space vector trajectory diameter can also be used for the localization of inverter power switch open-circuit faults [7], [8].”
BackgroundRothenhagen, K., & Fuchs, F. W. (2005) · 2005 European Conference on Power Electronics and Applications · doi:10.1109/epe.2005.219426 · Cited by 194
“Other researchers have developed several detection methods for open transistor faults [4, 5, 6].”
BackgroundMethodFreire, N. M. A., Estima, J. O., & Cardoso, A. J. M. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2279383 · Cited by 167
“of the current space vector was performed in [8] and [9] by the slope of the vector trajectory.”
BackgroundBhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
“Generally, the actuator faults are also related to power supply or the semiconductor devices[49].”
BackgroundFaults and Diagnosis Systems in Power Converters
Lee, K.-B., & Choi, U.-M. (2014) · Studies in Computational Intelligence · doi:10.1007/978-3-319-03401-0_4 · Cited by 6
D-Q current signature based single winding open fault detection for SM-PMAC machine drives
Kuruppu, S. S., & Kulatunga, N. A. (2013) · 2013 International Electric Machines & Drives Conference · doi:10.1109/iemdc.2013.6556310 · Cited by 5
Metadata
- Authors
- Peuget, R., Courtine, S., & Rognon, J. P.
- Venue
- IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting
- Publisher
- IEEE
- Published
- 2002-11-22
- Volume
- 2
- Pages
- 1471-1478
- ISSN
- 0197-2618 (ISSN-L)
- OpenAlex
- W2145830182
- Cited by
- 304
- References
- 6
- FWCI
- 12.22
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.