Study of midfield wireless power transfer for implantable medical devices

Keerthi., K.S, Ilango., K, Manjula., G. Nair·2018·2018 2nd International Conference on Biomedical Engineering (IBIOMED)

Abstract

Mid-field wireless power transfer (MF-WPT) is a scheme developed for transcutaneous power transfer to microimplants kept deep inside the body in GHz frequency.With deep seated implants, the possible locations available for application increases to almost the entire body. But, this advantage of applicability is severely limited as the power delivered to the micro implants by MF-WPT is very low -in the range of few 100W. Yet, the mid-field operations have higher efficiency in miniaturized weakly coupled coil implants compared to traditional near-field system. So, with improvement in certain aspects, MF-WPT is expected to play a vital role in biomedical field. For the same reason this paper focuses on analyses of literature available in various aspects of MF-WPT, its challenges, drawbacks and future scope of the scheme in medical field.

Integrity signals

Registry

Crossref · 10.1109/ibiomed.2018.8534820

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Midfield Transfer (MDF) occupies an intermediate range, offering a compromise between the close proximity required by NFC and the longer reach of RF.

    “MDF occupies an intermediate range, offering a compromise between the close proximity required by NFC and the longer reach of RF (Ho et al., 2014; Keerthi et al., 2018).”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Keerthi et al., 2018

  • NFC's need for close proximity between the transmitter and implant is beneficial in minimizing electromagnetic exposure and ensuring targeted energy transfer.

    “NFC’s need for close proximity between the transmitter and implant, while potentially limiting in terms of positioning, is beneficial in minimizing electromagnetic exposure and ensuring targeted energy transfer (Freudenthal et al., 2007; Keerthi et al., 2018).”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Keerthi et al., 2018

  • MDF is particularly suitable for implants located deeper in the brain.

    “This makes it particularly suitable for implants located deeper in the brain (Ho et al., 2014; Dinis et al., 2017; Keerthi et al., 2018).”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Keerthi et al., 2018

  • The operating frequency for MDF is typically in the range of tens to hundreds of megahertz.

    “The operating frequency for MDF is typically in the range of tens to hundreds of megahertz (Keerthi et al., 2018).”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Keerthi et al., 2018

  • MDF can transfer energy over larger distances relative to the size of the transmitter and receiver than inductive coupling, which is limited by mutual inductance between closely spaced coils.

    “Unlike inductive coupling, which is limited by the mutual inductance between closely spaced coils, MDF can transfer energy over larger distances relative to the size of the transmitter and receiver.”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Keerthi et al., 2018

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Keerthi., K. S., Ilango., K., & Manjula., G. N.
Affiliations
Amrita Vishwa Vidyapeetham (IN)
Venue
2018 2nd International Conference on Biomedical Engineering (IBIOMED)
Publisher
IEEE
Published
2018-07
Pages
44-47
OpenAlex
W2901888276
Cited by
17
References
21
Citations by year
2025: 2 · 2024: 2 · 2023: 5 · 2022: 1 · 2021: 3 · 2020: 2 · 2019: 2
FWCI
2.79
Type
conference paper
Language
en
Open access
closed
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Physical Sciences › Engineering › Mechanical Engineering › Induction Heating and Inverter Technology
Keywords
biomedical implants, transcutaneous power transfer, mini-implants, power delivery efficiency, GHz frequency range

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review