Development of a wristwatch-type PPG array sensor module
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this work, we address a new photoplethysmography (PPG) signal sensing method using a wristwatch-type PPG array sensor. According to the development of the ubiquitous health care system, the many types of medical equipment and treatments have been improved. In conventional PPG signal sensing approaches, the finger-type PPG probe has been used. However, the finger-type PPG probe requires tight fitting that restricts movement, meaning that patients should endure dome discomfort while wearing it. To solve this problem, we propose a novel PPG array sensor module with a wristwatch-type design. The proposed module measures the PPG signal from the radial artery and the ulnar artery of the wrist, whereas previous methods obtained it from capillaries of the skin. Moreover, we placed photo transistors (ST-23G) and infrared emitting diodes (EL-23G) in an array form to improve the PPG signal sensitivity and level of accuracy. Various arrays are considered for optimization, and a conductive fiber wristband is employed to reduce external noise. In the experiments, the proposed module is assessed and compared with the commercial product TSD200 by Biopac, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wearable, Cuff-less PPG-Based Blood Pressure Monitor with Novel Height Sensor
Shaltis, P. A., Reisner, A., & Asada, H. H. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260027 · Cited by 77
Cited by
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
“In the experiments, the proposed module was assessed and compared with the commercially available product produced by BIOPAC [16].”
BackgroundMethodInfluentialCurrent progress of photoplethysmography and SPO2 for health monitoring
Tamura, T. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00097-w · Cited by 247
“In recent years, various measurement sites for PPG sensors have been explored, including the ring finger [33], wrist [34, 35], brachia [11, 36, 37], in-ear [38], earlobe [39, 40], external ear cartilage [41–43], and superior auricular region [44–46].”
BackgroundScardulla, F., D’Acquisto, L., Colombarini, R., Hu, S., Pasta, S., & Bellavia, D. (2020) · Sensors · doi:10.3390/s20185052 · Cited by 72
Metadata
- Authors
- Lee, Y., Shin, H., Jo, J., & Lee, Y.-K.
- Venue
- 2011 IEEE International Conference on Consumer Electronics -Berlin (ICCE-Berlin)
- Publisher
- IEEE
- Published
- 2011-09
- Pages
- 168-171
- OpenAlex
- W2012332208
- Cited by
- 40
- References
- 1
- FWCI
- 2.71
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a wristwatch-type PPG array sensor module. https://app.cochat.ai/papers/10.1109/icce-berlin.2011.6031811
- The paper
- Lee, Y., Shin, H., Jo, J., & Lee, Y.-K. (2011). Development of a wristwatch-type PPG array sensor module. 2011 IEEE International Conference on Consumer Electronics -Berlin (ICCE-Berlin). https://doi.org/10.1109/icce-berlin.2011.6031811
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.