Cited by 73Non-Invasive Vital Sign MonitoringHeart Rate Variability and Autonomic ControlAdvanced Sensor and Energy Harvesting Materials

A Study on the Effect of Contact Pressure during Physical Activity on Photoplethysmographic Heart Rate Measurements

Open access
Scardulla, Francesco, D’Acquisto, Leonardo, Colombarini, Raffaele, Hu, Sijung, Pasta, Salvatore, Bellavia, Diego·2020·Sensors

Abstract

Heart rate (HR) as an important physiological indicator could properly describe global subject’s physical status. Photoplethysmographic (PPG) sensors are catching on in field of wearable sensors, combining the advantages in costs, weight and size. Nevertheless, accuracy in HR readings is unreliable specifically during physical activity. Among several identified sources that affect PPG recording, contact pressure (CP) between the PPG sensor and skin greatly influences the signals. Methods: In this study, the accuracy of HR measurements of a PPG sensor at different CP was investigated when compared with a commercial ECG-based chest strap used as a test control, with the aim of determining the optimal CP to produce a reliable signal during physical activity. Seventeen subjects were enrolled for the study to perform a physical activity at three different rates repeated at three different contact pressures of the PPG-based wristband. Results: The results show that the CP of 54 mmHg provides the most accurate outcome with a Pearson correlation coefficient ranging from 0.81 to 0.95 and a mean average percentage error ranging from 3.8% to 2.4%, based on the physical activity rate. Conclusion: Authors found that changes in the CP have greater effects on PPG-HR signal quality than those deriving from the intensity of the physical activity and specifically, the individual best CP for each subject provided reliable HR measurements even for a high intensity of physical exercise with a Bland–Altman plot within ±11 bpm. Although future studies on a larger cohort of subjects are still needed, this study could contribute a profitable indication to enhance accuracy of PPG-based wearable devices.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s20185052

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Higher contact pressures have been found to increase the accuracy of heart rate monitoring during exercise.

    “Higher contact pressures have been found to increase the accuracy of HR monitoring during exercise [71].”

    From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [71]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Scardulla, F., D’Acquisto, L., Colombarini, R., Hu, S., Pasta, S., & Bellavia, D.
Affiliations
  • University of Palermo (IT)
  • Loughborough University (GB)
  • Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione (IT)
Corresponding author
Scardulla, Francesco
Venue
Sensors
Publisher
MDPI AG
Published
2020-09-05
Volume
20
Issue
18
Pages
5052
ISSN
1424-8220 (ISSN-L)
OpenAlex
W3083287016
Cited by
72
References
59
Citations by year
2026: 10 · 2025: 20 · 2024: 11 · 2023: 12 · 2022: 15 · 2021: 3 · 2020: 1
FWCI
2.44
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Figshare (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Nova Science Publishers (Nova Science Publishers, Inc.) (submittedVersion, other-oa)
Funders
  • Loughborough University
  • Università degli Studi di Palermo
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
photoplethysmography, heart rate measurement, contact pressure, physical activity, wearable sensors, wristband, chest strap, signal quality, exercise intensity
MeSH terms
Wearable Electronic Devices, Heart Rate, Humans, Signal Processing, Computer-Assisted, Exercise, Photoplethysmography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review