Power Electronic Transformer application to grid connected photovoltaic systems
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Grid-connected photovoltaic systems utilize static converters which influence the efficiency of the system. The energy conversion depends on the architecture of the converter, different solutions are available and H-bridge multilevel converters seem to be an optimal solution also for the power quality. In the paper is proposed an architecture that includes a power electronic transformer which is practically an isolated high-frequency link AC/AC converter that substitute a conventional transformer. An MPPT control technique is presented and validated by simulation implemented on a photovoltaic system with H-bridge n-levels converter and power electronic transformer. The simulation results confirm that the control is able to effectively track the maximum power point and to stabilize immediately in the new steady-state condition.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Analysis and design of electronic transformers for electric power distribution system
Kang, M., Enjeti, P. N., & Pitel, I. J. (1999) · IEEE Transactions on Power Electronics · doi:10.1109/63.803407 · Cited by 365
The universal power electronics based distribution transformer, an unified approach
Heinemann, L., & Mauthe, G. (2002) · 2001 IEEE 32nd Annual Power Electronics Specialists Conference (IEEE Cat. No.01CH37230) · doi:10.1109/pesc.2001.954164 · Cited by 108 · cited 1×
“It may be seen that the literature has extended the application of high-frequency link AC transformation not only for low-level electronic power conversion but also for medium-level distribution power transformers [1, 2 ]. The major payoff expected is size reduction.”
BackgroundControl of high-frequency AC link electronic transformer
Krishnaswami, H., & Ramanarayanan, V. (2005) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20055022 · Cited by 86
Design of an electronic power transformer
Wrede, H., Staudt, V., & Steimel, A. (2003) · IEEE 2002 28th Annual Conference of the Industrial Electronics Society. IECON 02 · doi:10.1109/iecon.2002.1185477 · Cited by 35 · cited 1×
“MV grid transforms voltages and currents from basic frequency of 50 Hz into a medium frequency MT. Different frequency converter schemes have been presented and discussed in literature relating to realization in distribution grid application with modern power electronic devices such as i.e.: three-phase to three-phase…”
BackgroundBrando, G., Dannier, A., & Rizzo, R. (2007) · International Conference on Clean Electrical Power · doi:10.1109/iccep.2007.384305 · Cited by 31
Self-citation
Cited by
Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“In [121], the utilization of SST in grid-connected photovoltaic systems is introduced.”
BackgroundReview of solid state transformer in the distribution system: From components to field application
She, X., Burgos, R., Wang, G., Wang, F., & Huang, A. Q. (2012) · 2012 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2012.6342269 · Cited by 241
She, X., Huang, A. Q., Wang, F., & Burgos, R. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2216245 · Cited by 161
A review on solid-state transformer: A breakthrough technology for future smart distribution grids
Mishra, D. K., Ghadi, M. J., Li, L., Hossain, M. J., Zhang, J., Ray, P. K., & Mohanty, A. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.107255 · Cited by 130
An overview of Power Electronic Transformer: Control strategies and topologies
Dannier, A., & Rizzo, R. (2012) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam.2012.6264573 · Cited by 49
“INTRODUCTION In the last years the utilization of PET is spreading in various applications [1,2], particularly in energy distribution system that even more are distributed generation smart systems with renewable sources [3-7].”
BackgroundSelf-citationMoonem, M. A., & Krishnaswami, H. (2014) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2014.6803734 · Cited by 52
“In [9] a multi-stage dc-ac converter is used along with a high frequency transformer with MPPT control integrated into the converter.”
BackgroundMethodBrando, G., Dannier, A., Pizzo, A. D., & Rizzo, R. (2010) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2010.5607930 · Cited by 42
Self-citationShe, X., Wang, F. “., Burgos, R. P., & Huang, A. Q. (2012) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2012.6342508 · Cited by 42
State of the art of active power electronic transformers for smart grids
Roasto, I., Romero‐Cadaval, E., Martins, J. F., & Smoleński, R. (2012) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2012.6389543 · Cited by 28
An Innovative Reconfigurable Integrated Converter Topology Suitable for Distributed Generation
Rizzo, R., Tricoli, P., & Spina, I. (2012) · Energies · doi:10.3390/en5093640 · Cited by 21
“Electric storage devices can compensate for the mismatch between the power generated and that consumed by the loads, keeping the desired value of the power flow at the connection point [2].”
BackgroundSelf-citationSolid state transformer technologies and applications: A bibliographical survey
Adabi, M. E., Universitat Politecnica de Catalunya, B., & Martinez-Velasco, J. A. (2018) · AIMS energy · doi:10.3934/energy.2018.2.291 · Cited by 20
Huang, H. X., Mao, C., Lu, J., & Wang, D. (2014) · Energies · doi:10.3390/en7117330 · Cited by 19
Mejía, A. E., Liu, Y., Balda, J. C., & George, K. (2014) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6953992 · Cited by 9
“Advantages such as volume and weight reduction make the MF- and HF-XFMR more attractive for particular applications [12], [13].”
BackgroundThe Topology Analysis and Compare of High-Frequency Power Electronic Transformer
Li, C., Xie, Y., Lu, X., & Wang, Z. (2012) · Asia-Pacific Power and Energy Engineering Conference (APPEEC) · doi:10.1109/appeec.2012.6306929 · Cited by 6
A Distribution Power Electronic Transformer with MMC
Brando, G., Bova, B., Cervone, A., Dannier, A., & Pizzo, A. D. (2018) · Applied Sciences · doi:10.3390/app8010120 · Cited by 6
Self-citationBrando, G., Dannier, A., Pizzo, A. D., & Spina, I. (2016) · Applied Sciences · doi:10.3390/app6090261 · Cited by 5
Self-citationLuhana, P. P., & Christian, A. N. (2017) · International Conference on Energy, Communication, Data Analytics and Soft Computing (ICECDS) · doi:10.1109/icecds.2017.8389529 · Cited by 5
“so to overcome this issue SST is introduced [1] SST has become a hot research direction recently owing to the rapid development of power devices [7-14].”
BackgroundThe average model of a three-phase three-stage Power Electronic Transformer
Ouyang, S., Liu, J., Wang, X., Wang, X., Meng, F., & Riffat, J. (2014) · International Power Electronics Conference (IPEC) · doi:10.1109/ipec.2014.6870080 · Cited by 4
Modeling and control of a cascaded multilevel converter‐based electronic power transformer
Huang, H. X., Zhang, J., Mao, C., Lu, J., & Wang, D. (2016) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.22215 · Cited by 4
Multi Transformer Cell Inverter with Reduced DC sources
Banaeı, M. R., Khounjahan, H., Salary, E., & Dehghanzadeh, A. R. (2012) · DergiPark (Istanbul University) · Cited by 4
A Bidirectional Double Uneven Power Converter Based DC–DC Converter for Solid-State Transformers
Park, K., & Lee, K. (2018) · Electronics · doi:10.3390/electronics7110334 · Cited by 4
Madhusoodhanan, S., Tripathi, A., Mainali, K., Patel, D., Kadavelugu, A., & Bhattacharya, S. (2015) · Applied Power Electronics Conference · doi:10.1109/apec.2015.7104422 · Cited by 1
A universal configurable sinusoidal modulator for H-bridge based converters implemented in FPGA
Košan, T., Jára, M., Blahník, V., & Peroutka, Z. (2015) · Digital Library (University of West Bohemia) · Cited by 3
Wide Voltage Range Dual Active Bridge PV Retrofit Storage System
Fornari, R., Immovilli, F., & Lorenzani, E. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8926933 · Cited by 2
“The vast majority of power electronics interfaces for grid connected PV plants are voltage source inverters (VSI) with an input boost converter, implementing MPPT algorithms to maximize PV energy extraction [9], [10].”
BackgroundPower Flow Analysis of On-Grid Photovoltaic Generation Using A Solid-State Transformer
Tumbelaka, H. H., Khoswanto, H., ng, T., & Ananda, S. A. (2024) · International Journal of Electrical and Electronics Engineering · doi:10.14445/23488379/ijeee-v11i3p114 · Cited by 1
Brando, G., Capaldi, P., & Rizzo, R. (2012) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam.2012.6264600 · Cited by 1
“New generation compact cogeneration systems are becoming an important solution in the distributed generation system [1] that is even more realized by means of so-called smart micro-grids which integrate also renewable sources [2-3] storage systems and power electronics to have a good power quality by means of proper c…”
BackgroundSelf-citationAn efficient small-power cogeneration-unit suitable for residential off-grid application
Capaldi, P., & Rizzo, R. (2012) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam.2012.6264599 · Cited by 1
“Therefore is necessary a control not more centralized but distributed and characterized by a bidirectional flux of powers and active grids taking care of power quality also by means of proper power electronic converters adequately controlled [1] [2] [3] [4] [5] [6] [7].”
BackgroundSelf-citationDirect Current Smart Micro-grids for Distributed Generation with Renewable Sources
Rizzo, R. (2013) · DOAJ (DOAJ: Directory of Open Access Journals) · Cited by 1
Self-citationBanaeı, M. R., & Salary, E. (2013) · DergiPark (Istanbul University) · Cited by 1
On-Grid Photovoltaic System Using A Solid-State Transformer
Tumbelaka, H. H., Khoswanto, H., Ananda, S. A., & Hoat, T. H. L. (2024) · International Conference on Green Energy, Computing and Sustainable Technology (GECOST) · doi:10.1109/gecost60902.2024.10475003
“Another system, the SST topology uses a multilevel H-bridge for LV inverters, and MV rectifiers and inverters [11].”
Method
Metadata
- Authors
- Brando, G., Dannier, A., & Rizzo, R.
- Affiliations
- University of Naples Federico II (IT)
- Venue
- 2009 International Conference on Clean Electrical Power
- Publisher
- IEEE
- Published
- 2009-06
- Pages
- 685-690
- OpenAlex
- W2097059319
- Cited by
- 31
- References
- 5
- Citations by year
- 2024: 2 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 3 · 2017: 1 · 2016: 2 · 2015: 1 · 2014: 4 · 2013: 4 · 2012: 10
- FWCI
- 5.27
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Conference on Clean Electrical Power (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Photovoltaic System Optimization Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Keywords
- solid-state transformer, grid-connected photovoltaic systems, maximum power point tracking, AC-AC converter, power quality, converter efficiency, MPPT control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.