Exploiting peak anisotropy for tracking through complex structures
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
This work shows that multi-fibre reconstruction techniques, such as Persistent Angular Structure (PAS) MRI or QBall Imaging, provide much more information than just discrete fibre orientations, which is all that previous tractography algorithms exploit from them. We show that the shapes of the peaks of the functions output by multiple-fibre reconstruction algorithms reflect the underlying distribution of fibres. Furthermore, we show how to exploit this extra information to improve Probabilistic Index of Connectivity (PICo) tractography. The method uses the Bingham distribution to model the uncertainty in fibre-orientation estimates obtained from peaks in the PAS or QBall Orientation Distribution Function (ODF). The Bingham model captures anisotropy in the uncertainty, allowing the method to track through fanning and bending structures, which previous methods do not recover reliably. We devise a new calibration procedure to construct a mapping from peak shape to Bingham parameters. We test the accuracy of the calibration using a bootstrap experiment. Finally, we show that exploiting the peak shape in this way can provide improved PICo tractography results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Probabilistic diffusion tractography with multiple fibre orientations: What can we gain?
Behrens, T. E. J., Berg, H. J., Jbabdi, S., Rushworth, M. F. S., & Woolrich, M. W. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.018 · Cited by 3,471 · cited 2×
“Hosey et al [34] and Behrens et al [33] extend the Bayesian approach from [31] to model up to two fibre-orientation estimates within each voxel.”
BackgroundCharacterization and propagation of uncertainty in diffusion-weighted MR imaging
Behrens, T. E. J., Woolrich, M. W., Jenkinson, M., Johansen‐Berg, H., Nunes, R. G., Clare, S., Matthews, P. M., Brady, J. M., & Smith, S. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10609 · Cited by 3,038
Non-invasive mapping of connections between human thalamus and cortex using diffusion imaging
Behrens, T. E. J., Johansen-Berg, H., Woolrich, M. W., Smith, S. M., Wheeler-Kingshott, C. A. M., Boulby, P. A., Barker, G. J., Sillery, E. L., Sheehan, K., Ciccarelli, O., et al. (2003) · Nature Neuroscience · doi:10.1038/nn1075 · Cited by 2,330 · cited 1×
“The technique has several applications; it can be used to detect white-matter diseases [28], generate atlases of connectivity of the brain [32] and in neurosurgical planning and evaluation [3, 20].”
MethodTuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
Tracking neuronal fiber pathways in the living human brain
Conturo, T. E., Lori, N. F., Cull, T. S., Akbudak, E., Snyder, A. Z., Shimony, J. S., McKinstry, R. C., Burton, H., & Raichle, M. E. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10422 · Cited by 1,774
Tournier, J.-D., Calamante, F., Gadian, D. G., & Connelly, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.037 · Cited by 1,635 · cited 3×
“It extends easily to similar algorithms such as Spherical Deconvolution .”
BackgroundMethodHigh angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548 · cited 1×
“Multi-tensor models [7, 11] overcome this limitation to some extent, but require knowledge of the number of fibre populations prior to fitting.”
BackgroundParker, G. J. M., Haroon, H. A., & Wheeler‐Kingshott, C. A. M. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10350 · Cited by 527 · cited 6×
“Parker et al [10, 26, 27], Cook et al [23] and Lazar et al [18] use a calibration procedure.”
MethodInfluentialSelf-citation
Cited by
Deterministic and probabilistic tractography based on complex fibre orientation distributions
Descoteaux, M., Deriche, R., Knosche, T. R., & Anwander, A. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2004424 · Cited by 698
“Other methods use calibration [31], [41], statistical techniques like Marko v Chain Monte Carlo [35], [22], and bootstraps [42] to infer a peak uncertainty of the fibre distributions.”
BackgroundMethodInfluentialQuantitative evaluation of 10 tractography algorithms on a realistic diffusion MR phantom
Fillard, P., Descoteaux, M., Goh, A., Gouttard, S., Jeurissen, B., Malcolm, J., Ramirez-Manzanares, A., Reisert, M., Sakaie, K., Tensaouti, F., et al. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.032 · Cited by 418
Probabilistic fiber tracking using the residual bootstrap with constrained spherical deconvolution
Jeurissen, B., Leemans, A., Jones, D. K., Tournier, J., & Sijbers, J. (2011) · Human Brain Mapping · doi:10.1002/hbm.21032 · Cited by 369
Dell'Acqua, F., Scifo, P., Rizzo, G., Catani, M., Simmons, A., Scotti, G., & Fazio, F. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.09.033 · Cited by 304
Building connectomes using diffusion MRI: why, how and but
Sotiropoulos, S. N., & Zalesky, A. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3752 · Cited by 290
Metadata
- Authors
- Seunarine, K. K., Cook, P. A., Hall, M. G., Embleton, K. V., Parker, G. J. M., & Alexander, D. C.
- Venue
- 2007 IEEE 11th International Conference on Computer Vision
- Publisher
- IEEE
- Published
- 2007
- Pages
- 1-8
- OpenAlex
- W2111442680
- Cited by
- 58
- References
- 8
- FWCI
- 19.97
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.