The Argus® II retinal prosthesis system: An overview
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The Argus II Retinal Prosthesis System is the only commercially-approved treatment for severe to profound Retinitis Pigmentosa in the world. Over 10 years of research and development have gone into this device; it is now commercially available in the European Economic Area, Saudi Arabia, and in the United States. The Argus II System consists of an implant (including an epiretinal electrode array, an electronics case, and a receiver antenna), as well as a body-worn computer and a pair of glasses with a miniature video camera. It converts video images from the camera into stimulation patterns that are transmitted to the implant in real time, allowing users to perceive patterns of light. All aspects of the System have been extensively bench tested and found to provide long-term reliability. These findings have been borne out in a clinical trial; in over 120 subject-years of testing, there has been only one device failure. Clinical trial results have established the safety and probable benefit of the Argus II System.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819 · cited 1×
“Many different groups worldwide are investigating retinal prostheses; some approaches involve inserting an electrode or photodiode array subretinally, near the photoreceptors [1], [2], some insert an array epiretinally, near the ganglion cells [3], while others involve placing an array in the suprachoroidal space [4],…”
BackgroundInterim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700
Self-citationAhuja, A. K., Dorn, J. D., Caspi, A., McMahon, M. J., Dagnelie, G., daCruz, L., Stanga, P., Humayun, M. S., Greenberg, R. J., & Argus II Study Group (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.179622 · Cited by 289
Self-citationDorn, J. D., Ahuja, A. K., Caspi, A., da Cruz, L., Dagnelie, G., Sahel, J.-A., Greenberg, R. J., McMahon, M. J., & Argus II Study Group, F. T. (2013) · JAMA Ophthalmology · doi:10.1001/2013.jamaophthalmol.221 · Cited by 177
Self-citation
Cited by
Translating the Brain-Machine Interface
Thakor, N. V. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007303 · Cited by 128
Semantic and structural image segmentation for prosthetic vision
Sanchez-Garcia, M., Martinez-Cantin, R., & Guerrero, J. J. (2020) · PLOS ONE · doi:10.1371/journal.pone.0227677 · Cited by 62
Li, H., Su, X., Wang, J., Kan, H., Han, T., Zeng, Y., & Chai, X. (2018) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2017.11.001 · Cited by 59
Optimization of pillar electrodes in subretinal prosthesis for enhanced proximity to target neurons
Flores, T., Lei, X., Huang, T., Lorach, H., Dalal, R., Galambos, L., Kamins, T., Mathieson, K., & Palanker, D. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaac39 · Cited by 57
“In the epiretinal approach, arrays are implanted on top of the inner limiting membrane (ILM) [4], while subretinal prostheses are located between the inner nuclear layer (INL) and pigmented epithelium [5, 6].”
InfluentialBionic eye review - An update.
Nowik, K., Langwińska-Wośko, E., Skopiński, P., Nowik, K. E., & Szaflik, J. P. (2020) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2020.05.041 · Cited by 49
Metadata
- Authors
- Zhou, D. D., Dorn, J. D., & Greenberg, R. J.
- Venue
- 2013 IEEE International Conference on Multimedia and Expo Workshops (ICMEW)
- Publisher
- IEEE
- Published
- 2013-07
- Pages
- 1-6
- ISSN
- 2330-7927 (ISSN-L)
- OpenAlex
- W1984532536
- Cited by
- 70
- References
- 4
- FWCI
- 16.03
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.