The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Active Leg Exoskeleton (ALEX) for Gait Rehabilitation of Motor-Impaired Patients
Abstract
This paper describes the design and human machine interface of an Active Leg EXoskeleton (ALEX) for gait rehabilitation of patients with walking disabilities. The paper proposes force-field controller which can apply suitable forces on the leg to help it move on a desired trajectory. The interaction forces between the subject and the orthosis are designed to be 'assist-as-needed' for safe and effective gait training. Simulations and experimental results with the force-field controller are presented. Experiments have been performed with healthy subjects walking on a treadmill. It was shown that a healthy subject could be retrained in about 45 minutes with ALEX to walk on a treadmill with a significantly altered gait. In the coming months, this powered orthosis will be used for gait training of stroke patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Armstrong-Hélouvry, B., Dupont, P., & De Wit, C. C. (1994) · Automatica · doi:10.1016/0005-1098(94)90209-7 · Cited by 2,678
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,114
Veneman, J. F., Ekkelenkamp, R., Kruidhof, R., van der Helm, F. C. T., & van der Kooij, H. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906063829 · Cited by 428 · cited 2×
“In contrast with LOPES, ALEX does not use series elastic actuation for backdrivability of the device.”
BackgroundA mechanized gait trainer for restoration of gait.
Hesse, S., & Uhlenbrock, D. (2000) · PubMed · Cited by 388
Power Assist System HAL-3 for Gait Disorder Person
Kawamoto, H., & Sankai, Y. (2002) · Lecture Notes in Computer Science · doi:10.1007/3-540-45491-8_43 · Cited by 346
Gravity-Balancing Leg Orthosis and Its Performance Evaluation
Banala, S. K., Agrawal, S. K., Fattah, A., Krishnamoorthy, V., Hsu, W.-L., Scholz, J., & Rudolph, K. (2006) · IEEE Transactions on Robotics · doi:10.1109/tro.2006.882928 · Cited by 199
Self-citationAssessment of Motion of a Swing Leg and Gait Rehabilitation With a Gravity Balancing Exoskeleton
Agrawal, S. K., Banala, S. K., Fattah, A., Sangwan, V., Krishnamoorthy, V., Scholz, J. P., & Hsu, W. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903930 · Cited by 154
Self-citationRehabilitation Robotics: a Wearable Exo-Skeleton for Tremor Assessment and Suppression
Rocon, E., Ruiz, A. F., Pons, J. L., Belda-Lois, J. M., & Sanchez-Lacuesta, J. J. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570451 · Cited by 87
Albu‐Schäffer, A., Bertleff, W., Rebele, B., Schäfer, B., Landzettel, K., & Hirzinger, G. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1642296 · Cited by 61
An Assistive Robotic Device That Can Synchronize to the Pelvic Motion During Human Gait Training
Aoyagi, D., Ichinose, W. E., Harkema, S. J., Reinkensmeyer, D. J., & Bobrow, J. E. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1502026 · Cited by 56
Cited by
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Lower-Limb Robotic Rehabilitation: Literature Review and Challenges
Díaz, I., Gil, J. J., & Sánchez, E. (2011) · Journal of Robotics · doi:10.1155/2011/759764 · Cited by 541
Recent developments and challenges of lower extremity exoskeletons
Chen, B., Ma, H., Qin, L.-Y., Gao, F., Chan, K.-M., Law, S.-W., Qin, L., & Liao, W.-H. (2016) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2015.09.007 · Cited by 501
“For example, in the control of the ALEX [27,28], the interaction forces between the wearer and ALEX is measured through two force/torque sensors mounted at the thigh and shank.”
BackgroundMethodRecent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.04.005 · Cited by 464
Metadata
- Authors
- Banala, S. K., Agrawal, S. K., & Scholz, J. P.
- Venue
- 2007 IEEE 10th International Conference on Rehabilitation Robotics
- Publisher
- IEEE
- Published
- 2007-06
- Pages
- 401-407
- ISSN
- 1945-7898 (ISSN-L)
- OpenAlex
- W2066751209
- Cited by
- 316
- References
- 14
- FWCI
- 18.39
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Active Leg Exoskeleton (ALEX) for Gait Rehabilitation of Motor-Impaired Patients. https://app.cochat.ai/papers/10.1109/icorr.2007.4428456
- The paper
- Banala, S. K., Agrawal, S. K., & Scholz, J. P. (2007). Active Leg Exoskeleton (ALEX) for Gait Rehabilitation of Motor-Impaired Patients. 2007 IEEE 10th International Conference on Rehabilitation Robotics. https://doi.org/10.1109/icorr.2007.4428456
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.