The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
SynRhythm: Learning a Deep Heart Rate Estimator from General to Specific
Abstract
Remote photoplethysmography (rPPG) based noncontact heart rate (HR) measurement from a face video has drawn increasing attention recently because of its potential applications in many scenarios such as training aid, health monitoring, and nursing care. Although a number of methods have been proposed, most of them are designed under certain assumptions and could fail when such assumptions do not hold. At the same time, while deep learning based methods have been reported to achieve promising results in many computer vision tasks, their use in rPPG-based heart rate estimation has been limited due to the very limited data available in public domain. To overcome this limitation and leverage the strong modeling ability of deep neural networks, in this paper, we propose a novel spatial-temporal representation for the HR signal and design a general-to-specific transfer learning strategy to train a deep heart rate estimator from a large volume of synthetic rhythm signals and a limited number of available face video data. Experiment results on the public-domain databases show the effectiveness of the proposed approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Robust pulse rate from chrominance-based rPPG
de Haan, G., & Jeanne, V. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2266196 · Cited by 1,378
DistancePPG: Robust non-contact vital signs monitoring using a camera
Kumar, M., Veeraraghavan, A., & Sabharwal, A. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.001565 · Cited by 417 · cited 1×
“In [15], Kumar et al.”
Cited by
Yu, Z., Peng, W., Li, X., Hong, X., & Zhao, G. (2019) · 2019 IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2019.00024 · Cited by 340
PhysFormer: Facial Video-based Physiological Measurement with Temporal Difference Transformer
Yu, Z., Shen, Y., Shi, J., Zhao, H., Torr, P., & Zhao, G. (2022) · 2022 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr52688.2022.00415 · Cited by 300
PhysFlow: Skin tone transfer for remote heart rate estimation through conditional normalizing flows
Comas, J., Alomar, A., Ruiz, A., & Sukno, F. (2024) · arXiv · doi:10.48550/arxiv.2407.21519 · Cited by 4
“Some combine traditional methods with Convolutional Neural Networks (CNNs) to leverage advanced features [34, 36, 47].”
Method
Metadata
- Authors
- Niu, X., Han, H., Shan, S., & Chen, X.
- Venue
- 2018 24th International Conference on Pattern Recognition (ICPR)
- Publisher
- IEEE
- Published
- 2018-08
- Pages
- 3580-3585
- ISSN
- 1041-3278 (ISSN-L)
- OpenAlex
- W2903521046
- Cited by
- 174
- References
- 5
- FWCI
- 32.52
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SynRhythm: Learning a Deep Heart Rate Estimator from General to Specific. https://app.cochat.ai/papers/10.1109/icpr.2018.8546321
- The paper
- Niu, X., Han, H., Shan, S., & Chen, X. (2018). SynRhythm: Learning a Deep Heart Rate Estimator from General to Specific. 2018 24th International Conference on Pattern Recognition (ICPR). https://doi.org/10.1109/icpr.2018.8546321
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.