On task-oriented criteria for configurations selection in robot calibration
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
This paper studies different criteria for selecting configurations for the task of calibrating a robotic system. Given an automatic and self-contained procedure which allows the robot to calibrate itself without the need of external tools, we are interested in how to select the set of configurations that maximize calibration accuracy while minimizing calibration time. We experiment with the active calibration of a multi-sensorial humanoid's upper body and report that determinant-based criteria should be preferred when a greedy selection is used. In addition to criteria comparison, we further propose a new criterion for configuration selection. Its novelty stems from a direct treatment of the robot's end-effector tool variance. This is contrary to previous approaches which target the variance indirectly via calibration parameters. Our proposed objective function is derived as a compact formulation from the mean error of the robot's end-effector tool from which its variance can be computed using traditional criteria known from the theory of optimal experimental design (e.g. A-optimality).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
General Equivalence Theory for Optimum Designs (Approximate Theory)
Kiefer, J. (1974) · The Annals of Statistics · doi:10.1214/aos/1176342810 · Cited by 761 · cited 2×
“One may replace the trace operator in (4) for, in this case, another uncertainty measuring operator, such as the determinant (i.e. D-optimality) or the maximum eigenvalue (i.e. E-optimality) as stated in Tab.”
Pukelsheim, F. (2006) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898719109 · Cited by 684
An Algorithm for the Construction of "D-Optimal" Experimental Designs
Mitchell, T. J. (2000) · Technometrics · doi:10.2307/1271431 · Cited by 421
Direct calculation of minimum set of inertial parameters of serial robots
Gautier, M., & Khalil, W. (1990) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.56655 · Cited by 412 · cited 3×
“In the above context, a first proposal called OC was introduced by Gautier and Khalil [5].”
BackgroundMethodThe Calibration Index and Taxonomy for Robot Kinematic Calibration Methods
Hollerbach, J. M., & Wampler, C. W. (1996) · The International Journal of Robotics Research · doi:10.1177/027836499601500604 · Cited by 293
An Algorithm for the Construction of "D-Optimal" Experimental Designs
Mitchell, T. J. (1974) · Technometrics · doi:10.2307/1267940 · Cited by 267
Borm, J.-H., & Meng, C.-H. (1991) · The International Journal of Robotics Research · doi:10.1177/027836499101000106 · Cited by 229 · cited 5×
“A second approach O D is due to Borm and Menq [2], and their proposal was based on the minimum ellipsoid's error of the estimated parameters.”
BackgroundMethodInfluentialObservability index selection for robot calibration
Sun, Y., & Hollerbach, J. M. (2008) · 2008 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2008.4543308 · Cited by 173 · cited 4×
“Table I shows row-wise the relation between the observability indexes and the TOED criteria as reported in [8].”
BackgroundResultInfluentialThe noise amplification index for optimal pose selection in robot calibration
Nahvi, A., & Hollerbach, J. M. (2002) · Proceedings of IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1996.503848 · Cited by 162 · cited 1×
“These include dividing randomly sampled configurations from the workspace in sets and selecting the set with best observability index [2], or a greedy search with an exchange scheme over a sampled set of configurations until a maximum number of configurations or desired accuracy is reached [6], [7], [13], [14].”
MethodChoosing Measurement Poses for Robot Calibration with the Local Convergence Method and Tabu Search
Daney, D., Papegay, Y., & Madeline, B. (2005) · The International Journal of Robotics Research · doi:10.1177/0278364905053185 · Cited by 152 · cited 1×
“Measurement selection using an evolutionary scheme was introduced in [16], [17].”
Method
Cited by
Past, Present, and Future of Simultaneous Localization and Mapping: Toward the Robust-Perception Age
Cadena, C., Carlone, L., Carrillo, H., Latif, Y., Scaramuzza, D., Neira, J., Reid, I., & Leonard, J. J. (2016) · IEEE Transactions on Robotics · doi:10.1109/tro.2016.2624754 · Cited by 3,596
“Uncertainty metrics from TOED, which are task oriented, seem promising as stopping criteria, compared to information-theoretic metrics which are difficult to compare across systems [42].”
Self-citationPast, present, and future of simultaneous localization and mapping: Toward the robust-perception age
Cadena, C., Carlone, L., Carrillo, H., Latif, Y., Scaramuzza, D., Neira, J., Reid, I. D., & Leonard, J. J. (2016) · Zurich Open Repository and Archive (University of Zurich) · doi:10.5167/uzh-138892 · Cited by 3,048
Self-citationIoT-based system for indoor location using bluetooth low energy
Terán, M., Aranda, J. M., Carrillo, H., Méndez, D., & Parra, C. (2017) · IEEE Colombian Conference on Communications and Computing (COLCOM) · doi:10.1109/colcomcon.2017.8088211 · Cited by 88
“As well, IoT is used in conjunction with other technologies such as: Simultaneous localization and mapping (SLAM) [1], robotic calibration [2], Control Theory [3], among others.”
MethodSelf-citationWang, W., Song, H., Yan, Z., Sun, L., & Du, Z. (2017) · Robotics and Computer-Integrated Manufacturing · doi:10.1016/j.rcim.2017.09.011 · Cited by 80
Autonomous robotic exploration using a utility function based on Rényi’s general theory of entropy
Carrillo, H., Dames, P., Kumar, V., & Castellanos, J. A. (2017) · Autonomous Robots · doi:10.1007/s10514-017-9662-9 · Cited by 73
“The experiments with A - opt show that it is more conservative than D - opt , which agrees with the findings of Carrillo et al. (2012a, 2013, 2012b).”
ResultSelf-citationApplication-oriented selection of poses and forces for robot elastostatic calibration
Kalas, V. J., Vissière, A., Krut, S., Noiré, P., Roux, T., & Pierrot, F. (2021) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2020.104176 · Cited by 36
Birbach, O., Frese, U., & Bäuml, B. (2014) · The International Journal of Robotics Research · doi:10.1177/0278364914548201 · Cited by 27
“To gather the required sensor data the robot replays a set of prerecorded arm configurations which were heuristically chosen (see Carrillo et al. (2013) for a more elaborate approach) to cover a wide range of different kinematic configurations and distances to the cameras in mind.”
MethodSelf-citationWhole-body self-calibration via graph-optimization and automatic configuration selection
Maier, D., Wrobel, S., & Bennewitz, M. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7139992 · Cited by 14
“To this end, we evaluated the following observability indices [11, 14]:”
BackgroundMethodIntegrated on-line robot-camera calibration and object pose estimation
Pauwels, K., & Kragić, D. (2016) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2016.7487383 · Cited by 15
“In accordance with [7], [12] we use the following index:”
BackgroundMethodResidual index for measurement configuration optimization in robot kinematic calibration
Ye, H., & Wu, J. (2023) · Science China Technological Sciences · doi:10.1007/s11431-022-2409-1 · Cited by 12
“Although there are some preliminary studies on the index based on the calibration residual, they have not received attention due to the unreasonable optimization objectives and the lack of systematic analysis [21, 22].”
BackgroundBonnet, V., Mirabel, J., Daney, D., Lamiraux, F., Gautier, M., & Stasse, O. (2023) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2023.104365 · Cited by 9
Han, C., Yu, Y., Xu, Z., Wang, X., Yu, P., & Zhou, X. (2019) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1177/0954406219869985 · Cited by 9
Tenhumberg, J., Sievers, L., & Bäuml, B. (2023) · IEEE-RAS International Conference on Humanoid Robots (Humanoids) · doi:10.1109/humanoids57100.2023.10375208 · Cited by 6
“Following Carrillo et al. [22], we use task D-optimality to select appropriate samples for measuring.”
BackgroundMethodSelf-Contained Calibration of an Elastic Humanoid Upper Body Using Only a Head-Mounted RGB Camera
Tenhumberg, J., Winkelbauer, D., Burschka, D., & Bäuml, B. (2022) · IEEE-RAS International Conference on Humanoid Robots (Humanoids) · doi:10.1109/humanoids53995.2022.10000184 · Cited by 5
“In previous work, the multi-sensorial head [13], the IMUs in the head and base [14], and the eye-hand chain [15] were calibrated.”
MethodCalibration of an Elastic Humanoid Upper Body and Efficient Compensation for Motion Planning
Tenhumberg, J., & Bäuml, B. (2021) · IEEE-RAS International Conference on Humanoid Robots (Humanoids) · doi:10.1109/humanoids47582.2021.9555793 · Cited by 5
Navigation Under Uncertainty Based on Active SLAM Concepts
Carrillo, H., & Castellanos, J. A. (2015) · Studies in systems, decision and control · doi:10.1007/978-3-319-26327-4_9 · Cited by 4
Self-citationA General Batch-Calibration Framework of Service Robots
Zheng, K., Chen, Y., Wu, F., & Chen, X. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-65298-6_26 · Cited by 5
“The recent work [7,18] also designed specific algorithms to get better practical effects.”
BackgroundMontes, F., Villarreal, J., & Manrique, T. (2017) · IEEE Colombian Conference on Automatic Control (CCAC) · doi:10.1109/ccac.2017.8276411
Kalas, V. J. (2020) · theses.fr (ABES) · doi:10.70675/15500df2z263ez4cd6z8ae8zde5f379b5f4f
Robotized measurements : automated acoustic characterization of structures
Pascal, C. (2024) · theses.fr (ABES) · doi:10.70675/d68c712ez446ez4a4bza568zabaf3dc8aac2
Metadata
- Authors
- Carrillo, H., Birbach, O., Taubig, H., Bauml, B., Frese, U., & Castellanos, J. A.
- Affiliations
- Universidad de Zaragoza (ES)
- German Research Centre for Artificial Intelligence (DE)
- Venue
- 2013 IEEE International Conference on Robotics and Automation
- Publisher
- IEEE
- Published
- 2013-05
- Pages
- 3653-3659
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W1983905625
- Cited by
- 20
- References
- 23
- Citations by year
- 2024: 1 · 2023: 3 · 2022: 1 · 2021: 2 · 2020: 1 · 2019: 1 · 2017: 5 · 2016: 3 · 2015: 2 · 2014: 1
- FWCI
- 2.73
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Proceedings - IEEE International Conference on Robotics and Automation/Proceedings (publishedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Robotic Mechanisms and Dynamics
- Physical Sciences › Engineering › Control and Systems Engineering › Robot Manipulation and Learning
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Keywords
- robot calibration, configuration selection, active calibration, self-calibration, greedy selection, A-optimality, optimal experimental design, calibration accuracy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.